2010 CA08103002Z-EN     www.eaton.com PKZ and PKE motor-protective  circuit-breakers  Machinery and installation downtimes should be kept as short as possible. The PKZ  fuseless motor-protective circuit-breakers combine short-circuit and overload protection  in one device, allowing fast restart readiness. PKZM01, PKZM0, PKZM4 and PKE have  the same accessories. Combines easily with DILM contactors and DS7 soft starters.  Connecting PKE to SmartWire-Darwin facilitates high data transparency. PKZM01 (up to 16) motor-protective circuit-breaker with pushbuttons Motor-protective circuit-breaker in housing for protection types IP40 and IP65 +++ Integrated   EMERGENCY STOP and EMERGENCY OFF pushbuttons reduce wiring. PKZM0 (up to 32 A) and PKZM4 (up to 65 A) motor-protective circuit-breakers with rotary handle Short-circuit proof up to at least 50 kA for easy engineering +++ Trip-indicating auxiliary contact enables  remote diagnosis +++ High safety through application as main switch or repair and maintenance switch  +++ ATEX approval for protection of EEx e motors up to 65 APKE (up to 65 A) motor-protective circuit-breakers with electronic wide-range overload protection  High flexibility through plug-in trip block +++ Wide current setting ranges enable only five trip blocks up  to 65 A +++ Precise and extremely long-term stable characteristic curves +++   Individual supply through integrated current converter +++ ATEX approval for protection of EEx e motors  up to 65 A +++ Adjustable tripping classesDC string circuit-breakers PKZ-SOL and DC switch-disconnectors P-SOL (up to 63 A) for   installations  High string circuit-breaker flexibility due to wide current setting range +++ Enclosed switch-  disconnector for external mounting (IP65) +++ Remote shutdown through optional secondary voltage  and shunt trip +++ Voltage up to 1000 V DC +++ TÜV certified  ATEX

Motor-protective circuit-breakers Motor-protective circuit-breakers Motor-protective circuit-breaker PKZM01, PKZM0,   PKZM4, PKE System overview  PKZM01, PKZM0, PKZM4 motor-protective  7/2  circuit-breakers Ordering  Motor-protective circuit-breakers  7/3 Motor-protective circuit-breakers for starter  7/6  combinationsTransformer-protective circuit-breakers  7/6 PKE electronic motor-protective circuit-breaker  7/8 Auxiliary contacts  7/10 Auxiliary contacts, shunt releases  7/12 Engineering  Accessories for motor-protective circuit-breakers  7/14in enclosures  7/15 Ordering  Insulated enclosures  7/16 Accessories  7/20 Busbar adapters  7/22 Wiring sets  7/25 Three-phase commoning links  7/26 Actuating voltages  7/28 Engineering  Motor-protective circuit-breakers  7/30 Characteristic curves  7/30 Switching capacity  7/32 Technical data  Motor-protective circuit-breakers  7/36 Auxiliary contacts  7/38 Dimensions  PKZM01, PKZM0 motor-protective circuit-breaker  7/39Accessories  7/40 PKZM4 motor-protective circuit-breaker   7/45 Accessories  7/46 PKZ2 motor-protective circuit-breaker System overview  PKZ2 motor-protective circuit-breakers  7/47  Ordering  Motor-protective circuit-breakers  7/48 Circuit-breakers  7/48 Compact starters, high-capacity compact starters  7/50Motor protection modules  7/52 Modules for system protection  7/52 Insulated enclosures  7/56 Auxiliary contacts  7/58 Current limiters  7/58 Shunt releases  7/60 Remote operators  7/62 Contact modules  7/64 Accessories for contact modules  7/66 Accessories  7/68 Actuating voltages  7/70 Engineering  Characteristic curves  7/72 Switching capacity  7/74 Technical data  Motor-protective circuit-breakers  7/78 (High-capacity) contact modules  7/79 Current limiters  7/79 Auxiliary contacts  7/80 Shunt releases  7/80 Remote operators  7/81 Dimensions  Motor-protective circuit-breakers  7/82 Accessories  7/83 DC string circuit-breaker PKZ-SOL,   DC switch-disconnectors P-SOL, SOL Description DC switches P-SOL, PKZ-SOL, SOL  7/84 Ordering DC switch-disconnector SOL, ready-to-install  7/85 DC switch-disconnector P-SOL, open  7/86 DC string circuit-breaker PKZ-SOL  7/86 Engineering Circuit P-SOL, PKZ-SOL  7/87  Interior circuit SOLCharacteristic curves  7/88 Technical data DC switch-disconnectors P-SOL,SOL  7/89 DC string circuit-breaker PKZ-SOL  7/90 Dimensions DC switches P-SOL, PKZ-SOL, SOL  7/91 2 5 20 50 200 1 2 5 10 20 40 1 2 5 10 20 2 h 1.5 2 3 4 6 8 10 15 20 30 PKZM4-... mi n s ms x I r 14 x I u 45 AK-PKZ 0 AK-PKZ 0 93 50 88 94 45 2 5 20 50 200 1 2 5 10 20 40 1 2 5 2010 2h 1,5 2 3 4 6 8 10 15 20 30 PKZ2/ZM-... PKZ2/ZM-.../S PKZ2/ZM-.../SE1A Sekunden Milli-Sekunden Minuten x Bemessungsbetriebsstrom 6 0 + M4 105 19 ZMR 19 62.5 71.5 83 105 44.5 109 133.5 62 45 68 15    58 45 92.5 43.5 62 70 5.5 PKE... 2 1 20 10 5 2 1 20 10 5 2 1 500 200 100 50 20 10 5 2 100 30 40 50 70 20 15 10 7 5 4 3 2 1.5 1 1 t h min s ms x I r   12 x I r   14 x I u   CLASS5 CLASS20 CLASS10 CLASS15

2010 CA08103002Z-EN www.eaton.com 7/2 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Motor-protective circuit-breaker System overview 6 5 4 7 7 7 1 3 3 2 7 7 8 5 Basic devices Motor-protective circuit-breaker PKZM01 1 → Page 7/3 Motor-protective circuit-breaker PKZM0 2 → Page 7/4 Motor-protective circuit-breakerwith wide-range overload protection 3 → Page 7/8 Motor-protective circuit-breaker PKZM4 4 → Page 7/4 Add-on functions Standard auxiliary contacts 7 → Page 7/10 Shunt release 6 → Page 7/29 Current limiters 8 → Page 7/12 Mounting accessories Door coupling handles IP65 5 → Page 7/20 Insulated enclosure → Page 7/16 Mounting/wiring → Page 7/22

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE 2010 CA08103002Z-EN www.eaton.com 7/3 Ordering Screw terminals Max. motor ratingAC-3 Rated uninter-rupted current Setting range Part no.Article no. PriceSee price list Std. pack Information relevant for export to North America Overload releases Short-circuit releases 220 V230 V240 V 380 V400 V415 V  440 V P P P   I u I r I rm kW kW kW A A A Motor-protective circuit-breakers, type “1”; and type “2” coordination – – – 0.16 0.1…0.16 2.2 PKZM01-0.16278475 1 off Product StandardsUL 508; CSA-C22.2  No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Suitable for Branch circuit, or suitable for group installations See also → Page 7/34 – 0.06 0.06 0.25 0.16…0.25 3.5 PKZM01-0.25278476 0.06 0.09 0.12 0.4 0.25…0.4 5.6 PKZM01-0.4278477 0.09 0.12 0.18 0.63 0.4…0.63 8.8 PKZM01-0.63278478 0.12 0.25 0.25 1 0.63…1 14 PKZM01-1278479 0.25 0.55 0.55 1.6 1…1.6 22 PKZM01-1.6278480 0.37 0.75 1.1 2.5 1.6…2.5 35 PKZM01-2.5278481 0.75 1.5 1.5 4 2.5…4 56 PKZM01-4278482 1.1 2.2 3 6.3 4…6.3 88 PKZM01-6.3278483 2.2 4 4 10 6.3…10 140 PKZM01-10278484 3 5.5 5.5 12 8…12 168 PKZM01-12278485 4 7.5 9 16 10…16 224 PKZM01-16283390 5.5 9 11 20 16…20 280 PKZM01-20283383 Product StandardsUL 508; CSA-C22.2  No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified 5.5 12.5 12.5 25 20…25 350 PKZM01-25288893 Notes L T I  Accessories Page 3 Standard auxiliary contacts  → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29 Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height 6 3 5 3 PKZM01 HLP07003EN

7/4 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Motor-protective circuit-breaker Screw terminals Screw terminals on feed side, spring-loaded terminals on output side Spring-loaded terminals Circuit diagrams Max. motor ratingAC-3 Rated uninter-rupted current Setting range Part no.Article no. PriceSee price list Part no.Article no. PriceSee price list Part no.Article no. PriceSee price list Std. pack Notes Information relevant for export to North America Overload releases Short-circuit releases 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V 660 V 690 V P P P P P   I u I r I rm kW kW kW kW kW A A A Motor-protective circuit-breakers, type “1” and type “2”coordination 1) – – – – 0.06 0.16 0.1…0.16 2.2 PKZM0-0.16072730 PKZM0-0,16-SC229828 PKZM0-0,16-C229669 1 off 1) Product StandardsUL 508; CSA-C22.2 No. 14;  IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Suitable for Branch circuit: Manual type E if used with terminal, or suitable for group installations See also → Page 7/34 – 0.06 0.06 0.06 0.12 0.25 0.16…0.25 3.5 PKZM0-0.25072731 PKZM0-0,25-SC229829 PKZM0-0,25-C229670 0.06 0.09 0.12 0.12 0.18 0.4 0.25…0.4 5.6 PKZM0-0.4072732 PKZM0-0,4-SC229830 PKZM0-0,4-C229671 0.09 0.12 0.18 0.25 0.25 0.63 0.4…0.63 8.8 PKZM0-0.63072733 PKZM0-0,63-SC229831 PKZM0-0,63-C229672 0.12 0.25 0.25 0.37 0.55 1 0.63…1 14 PKZM0-1072734 PKZM0-1-SC229832 PKZM0-1-C229673 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 22 PKZM0-1.6072735 PKZM0-1,6-SC229833 PKZM0-1,6-C229674 0.37 0.75 1.1 1.1 1.5 2.5 1.6…2.5 35 PKZM0-2.5072736 PKZM0-2.5-SC229834 PKZM0-2.5-C229675 0.75 1.5 1.5 2.2 3 4 2.5…4 56 PKZM0-4072737 PKZM0-4-SC229835 PKZM0-4-C229676 1.1 2.2 3 3 4 6.3 4…6.3 88 PKZM0-6.3072738 PKZM0-6,3-SC229836 PKZM0-6,3-C229677 2.2 4 4 4 7.5 10 6.3…10 140 PKZM0-10072739 PKZM0-10-SC229837 PKZM0-10-C229678 3 5.5 5.5 5.5 11 12 8…12 168 PKZM0-12278486 PKZM0-12-SC278487 PKZM0-12-C278488 4 7.5 9 9 12.5 16 10…16 224 PKZM0-16046938 PKZM0-16-SC229838 PKZM0-16-C229679 5.5 9 11 12.5 15 20 16…20 280 PKZM0-20046988 5.5 12.5 12.5 15 22 25 20…25 350 PKZM0-25046989 7.5 15 15 22 30 32 25…32 448 PKZM0-32278489 Motor-protective circuit-breakers, type “1” and type “2” coordination 1) 4 7.5 9 9 12.5 16 10…16 224 PKZM4-16222350 1 off 5.5 12.5 12.5 15 22 25 16…25 350 PKZM4-25222352 7.5 15 17.5 22 22 32 25…32 448 PKZM4-32222353 11 20 22 24 30 40 32…40 560 PKZM4-40222354 14 25 30 30 45 50 40…50 700 PKZM4-50222355 17 30 37 37 55 58 50…58 812 PKZM4-58222394 18.5 34 37 45 55 65 55…65 882 PKZM4-63222413 Circuit-breakers 2) For line and cable protection – – – – – 16 10…16 224 PKZM4-16-CB132591 1 off Not usable as a main switch Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Switching capacity of SCCR65 kA (480 Y/277 V)22 kA (600 Y/347 V) 2) Product Standards UL 489; CSA-C22.2 no. 5-09; IEC60947-4-1; CE marking NA Certification Request filed for UL and CSA Specially designed for NA YesSuitable for Feeder and branch circuit as BCPD – – – – – 25 16…25 350 PKZM4-25-CB132592 – – – – – 32 25…32 448 PKZM4-32-CB132593 L T I  Accessories Page 3 Standard auxiliary contacts  → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29 Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.Can be snap-fit to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height PTB 02 ATEX 3151, see manual → 7/21 3 5 6 3 L T I  3 5 6 3 Accessories Page 3 Standard auxiliary contacts → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29Only motor-protective circuit-breaker:Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height PTB 02 ATEX 3153, see manual → 7/21 7/5 PKZM0, PKZM4 HPL07004EN PKZM0, PKZM4 HPL07005EN

7/4 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Motor-protective circuit-breaker Screw terminals Screw terminals on feed side, spring-loaded terminals on output side Spring-loaded terminals Circuit diagrams Max. motor ratingAC-3 Rated uninter-rupted current Setting range Part no.Article no. PriceSee price list Part no.Article no. PriceSee price list Part no.Article no. PriceSee price list Std. pack Notes Information relevant for export to North America Overload releases Short-circuit releases 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V 660 V 690 V P P P P P   I u I r I rm kW kW kW kW kW A A A Motor-protective circuit-breakers, type “1” and type “2”coordination 1) – – – – 0.06 0.16 0.1…0.16 2.2 PKZM0-0.16072730 PKZM0-0,16-SC229828 PKZM0-0,16-C229669 1 off 1) Product StandardsUL 508; CSA-C22.2 No. 14;  IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Suitable for Branch circuit: Manual type E if used with terminal, or suitable for group installations See also → Page 7/34 – 0.06 0.06 0.06 0.12 0.25 0.16…0.25 3.5 PKZM0-0.25072731 PKZM0-0,25-SC229829 PKZM0-0,25-C229670 0.06 0.09 0.12 0.12 0.18 0.4 0.25…0.4 5.6 PKZM0-0.4072732 PKZM0-0,4-SC229830 PKZM0-0,4-C229671 0.09 0.12 0.18 0.25 0.25 0.63 0.4…0.63 8.8 PKZM0-0.63072733 PKZM0-0,63-SC229831 PKZM0-0,63-C229672 0.12 0.25 0.25 0.37 0.55 1 0.63…1 14 PKZM0-1072734 PKZM0-1-SC229832 PKZM0-1-C229673 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 22 PKZM0-1.6072735 PKZM0-1,6-SC229833 PKZM0-1,6-C229674 0.37 0.75 1.1 1.1 1.5 2.5 1.6…2.5 35 PKZM0-2.5072736 PKZM0-2.5-SC229834 PKZM0-2.5-C229675 0.75 1.5 1.5 2.2 3 4 2.5…4 56 PKZM0-4072737 PKZM0-4-SC229835 PKZM0-4-C229676 1.1 2.2 3 3 4 6.3 4…6.3 88 PKZM0-6.3072738 PKZM0-6,3-SC229836 PKZM0-6,3-C229677 2.2 4 4 4 7.5 10 6.3…10 140 PKZM0-10072739 PKZM0-10-SC229837 PKZM0-10-C229678 3 5.5 5.5 5.5 11 12 8…12 168 PKZM0-12278486 PKZM0-12-SC278487 PKZM0-12-C278488 4 7.5 9 9 12.5 16 10…16 224 PKZM0-16046938 PKZM0-16-SC229838 PKZM0-16-C229679 5.5 9 11 12.5 15 20 16…20 280 PKZM0-20046988 5.5 12.5 12.5 15 22 25 20…25 350 PKZM0-25046989 7.5 15 15 22 30 32 25…32 448 PKZM0-32278489 Motor-protective circuit-breakers, type “1” and type “2” coordination 1) 4 7.5 9 9 12.5 16 10…16 224 PKZM4-16222350 1 off 5.5 12.5 12.5 15 22 25 16…25 350 PKZM4-25222352 7.5 15 17.5 22 22 32 25…32 448 PKZM4-32222353 11 20 22 24 30 40 32…40 560 PKZM4-40222354 14 25 30 30 45 50 40…50 700 PKZM4-50222355 17 30 37 37 55 58 50…58 812 PKZM4-58222394 18.5 34 37 45 55 65 55…65 882 PKZM4-63222413 Circuit-breakers 2) For line and cable protection – – – – – 16 10…16 224 PKZM4-16-CB132591 1 off Not usable as a main switch Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Switching capacity of SCCR65 kA (480 Y/277 V)22 kA (600 Y/347 V) 2) Product Standards UL 489; CSA-C22.2 no. 5-09; IEC60947-4-1; CE marking NA Certification Request filed for UL and CSA Specially designed for NA YesSuitable for Feeder and branch circuit as BCPD – – – – – 25 16…25 350 PKZM4-25-CB132592 – – – – – 32 25…32 448 PKZM4-32-CB132593 L T I  Accessories Page 3 Standard auxiliary contacts  → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29 Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.Can be snap-fit to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height PTB 02 ATEX 3151, see manual → 7/21 3 5 6 3 L T I  3 5 6 3 Accessories Page 3 Standard auxiliary contacts → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29Only motor-protective circuit-breaker:Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height PTB 02 ATEX 3153, see manual → 7/21 7/5 PKZM0, PKZM4 HPL07004EN PKZM0, PKZM4 HPL07005EN

7/6 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker for starter combinations and transformers 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker for starter combinations and transformers Motor-protective circuit-breaker for starter combinations and transformers Screw terminals Max. motor rating Rated uninterrupted current Setting range Part no.Article no. PriceSee price list Std. pack Notes AC-3 Overload releases Short-circuit releases 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V 660 V 690 V  I u I r I rm P P P P P A A A kW kW kW kW kW Motor-protective circuit-breakers for starter combinations Short-circuit protective breakers without overload function – – – – 0.06 0.16 2.2 PKM0-0,16072720 1 off – 0.06 0.06 0.06 0.12 0.25 3.5 PKM0-0,25072721    0.06 0.09 0.12 0.12 0.18 0.4 5.6 PKM0-0,4072722    0.09 0.12 0.18 0.25 0.25 0.63 8.8 PKM0-0,63072723    0.12 0.25 0.25 0.38 0.55 1 14 PKM0-1072724    0.25 0.37 0.55 0.75 1.1 1.6 22 PKM0-1,6072725    0.37 0.75 1.1 1.1 1.5 2.5 35 PKM0-2.5072726    0.75 1.5 1.5 2.2 3 4 56 PKM0-4072727    1.1 2.2 3 3 4 6.3 88 PKM0-6,3072728    2.2 4 4 4 7.5 10 140 PKM0-10072729    3 5.5 5.5 5.5 11 12 168 PKM0-12278490    4 7.5 9 9 12.5 16 224 PKM0-16044502    5.5 9 11 12.5 15 20 280 PKM0-20203594    5.5 12.5 12.5 15 22 25 350 PKM0-25044503    7.5 15 15 22 30 32 448 PKM0-32278491    Transformer-protective circuit-breakers – – – – – 0.16 0.1…0.16 2.4 PKZM0-0,16-T088907 1 off – – – – – 0.25 0.16…0.25 4.25 PKZM0-0,25-T088908    – – – – – 0.4 0.25…0.4 6.8 PKZM0-0,4-T088909    – – – – – 0.63 0.4…0.63 12 PKZM0-0,63-T088910    – – – – – 1 0.63…1 20 PKZM0-1-T088911    – – – – – 1.6 1…1.6 32 PKZM0-1,6-T088912    – – – – – 2.5 1.6…2.5 50 PKZM0-2.5-T088913    – – – – – 4 2.5…4 84 PKZM0-4-T088914    – – – – – 6.3 4…6.3 141 PKZM0-6,3-T088915    – – – – – 10 6.3…10 224 PKZM0-10-T088916    – – – – – 12 8…12 224 PKZM0-12-T278492    – – – – – 16 10…16 280 PKZM0-16-T088917    – – – – – 20 16…20 350 PKZM0-20-T088918    – – – – – 25 20…25 437 PKZM0-25-T278493    L T I  When using the PKM0 as short-circuit protection for motors with heavy starting duty, a device must be selected whose rated operational current I e  is higher  by the following factors:CLASS 5 = 1.0CLASS 10 = 1.0CLASS 15 = 1.22CLASS 20 = 1.41CLASS 25 = 1.58CLASS 30 = 1.73CLASS 35 = 1.89CLASS 40 = 2.0 Accessories Page 3 Standard auxiliary contacts  → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29 Additional accessories → 2/46 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm heightAssignment of the short-circuit protective breakers and contactors in “Fuseless motor-starter combinations” section.An appropriate overload relay must be fitted to protect motors against overload. 3 5 6 3 L T I  Accessories Page 3 Standard auxiliary contacts → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29 For the protection of transformers with a high inrush currentCan be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm heightPhase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. 3 5 6 3 7/7 PKZM0 HPL07006EN PKZM0 HPL07007EN

7/6 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker for starter combinations and transformers 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker for starter combinations and transformers Motor-protective circuit-breaker for starter combinations and transformers Screw terminals Max. motor rating Rated uninterrupted current Setting range Part no.Article no. PriceSee price list Std. pack Notes AC-3 Overload releases Short-circuit releases 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V 660 V 690 V  I u I r I rm P P P P P A A A kW kW kW kW kW Motor-protective circuit-breakers for starter combinations Short-circuit protective breakers without overload function – – – – 0.06 0.16 2.2 PKM0-0,16072720 1 off – 0.06 0.06 0.06 0.12 0.25 3.5 PKM0-0,25072721    0.06 0.09 0.12 0.12 0.18 0.4 5.6 PKM0-0,4072722    0.09 0.12 0.18 0.25 0.25 0.63 8.8 PKM0-0,63072723    0.12 0.25 0.25 0.38 0.55 1 14 PKM0-1072724    0.25 0.37 0.55 0.75 1.1 1.6 22 PKM0-1,6072725    0.37 0.75 1.1 1.1 1.5 2.5 35 PKM0-2.5072726    0.75 1.5 1.5 2.2 3 4 56 PKM0-4072727    1.1 2.2 3 3 4 6.3 88 PKM0-6,3072728    2.2 4 4 4 7.5 10 140 PKM0-10072729    3 5.5 5.5 5.5 11 12 168 PKM0-12278490    4 7.5 9 9 12.5 16 224 PKM0-16044502    5.5 9 11 12.5 15 20 280 PKM0-20203594    5.5 12.5 12.5 15 22 25 350 PKM0-25044503    7.5 15 15 22 30 32 448 PKM0-32278491    Transformer-protective circuit-breakers – – – – – 0.16 0.1…0.16 2.4 PKZM0-0,16-T088907 1 off – – – – – 0.25 0.16…0.25 4.25 PKZM0-0,25-T088908    – – – – – 0.4 0.25…0.4 6.8 PKZM0-0,4-T088909    – – – – – 0.63 0.4…0.63 12 PKZM0-0,63-T088910    – – – – – 1 0.63…1 20 PKZM0-1-T088911    – – – – – 1.6 1…1.6 32 PKZM0-1,6-T088912    – – – – – 2.5 1.6…2.5 50 PKZM0-2.5-T088913    – – – – – 4 2.5…4 84 PKZM0-4-T088914    – – – – – 6.3 4…6.3 141 PKZM0-6,3-T088915    – – – – – 10 6.3…10 224 PKZM0-10-T088916    – – – – – 12 8…12 224 PKZM0-12-T278492    – – – – – 16 10…16 280 PKZM0-16-T088917    – – – – – 20 16…20 350 PKZM0-20-T088918    – – – – – 25 20…25 437 PKZM0-25-T278493    L T I  When using the PKM0 as short-circuit protection for motors with heavy starting duty, a device must be selected whose rated operational current I e  is higher  by the following factors:CLASS 5 = 1.0CLASS 10 = 1.0CLASS 15 = 1.22CLASS 20 = 1.41CLASS 25 = 1.58CLASS 30 = 1.73CLASS 35 = 1.89CLASS 40 = 2.0 Accessories Page 3 Standard auxiliary contacts  → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29 Additional accessories → 2/46 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm heightAssignment of the short-circuit protective breakers and contactors in “Fuseless motor-starter combinations” section.An appropriate overload relay must be fitted to protect motors against overload. 3 5 6 3 L T I  Accessories Page 3 Standard auxiliary contacts → 7/10 5 Trip-indicating auxiliary contact → 7/12 6 Shunt release, undervoltage release → 7/29 For the protection of transformers with a high inrush currentCan be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm heightPhase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. 3 5 6 3 7/7 PKZM0 HPL07006EN PKZM0 HPL07007EN

7/8 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Motor-protective circuit-breaker Standard auxiliary contacts Motor full-load current Basic device Trip module Standard Trip module Expanded 1) Motor-protective circuit-breakers StandardComplete device Motor rating AC-3 Setting rangeOverload releases Part no.Article no. See price list Std. pack usable  for Part no.Article no. See price list Std. pack usable  for Part no.Article no. See price list Std. pack Part no.Article no. See price list Std. pack 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V 660 V 690 V P I I I I I kW A A A A A Motor-protective circuit-breakers, type  “1” and type “2”  coordination 0.06 0.37 – – – – 0.3...1.2  A PKE12121721 1off PKE12 PKE-XTU-1,2121723 1off PKE12 PKE-XTUA-1,2121727 1off PKE12/XTU-1,2121731 1off 0.09 0.54 0.31 – – – 0.12 0.72 0.41 0.37 0.33 – 0.18 1.04 0.6 0.54 0.48 0.35 0.25 – 0.8 0.76 0.7 0.5 0.37 – 1.1 1.02 0.9 0.7 0.55 – – – – 0.9 Start of delivery 07/2010 Start of delivery 07/2010 Start of delivery 07/2010 0.75 – – – – 1.1 0.18 1.04 – – – – 1...4  A PKE12121721 1off PKE12 PKE-XTU-4121724 1off PKE12 PKE-XTUA-4121728 1off PKE12/XTU-4121732 1off 0.25 1.4 – – – – 0.37 2 1.1 1.02 – – 0.55 2.7 1.5 1.39 1.2 – 0.75 3.2 1.9 1.68 1.5 1.1 1.1 – 2.6 2.41 2.1 1.5 1.5 – 3.6 3.28 2.9 2.1 2.2 – – – 4 2.9 Start of delivery 05/2010 3 – – – – 3.8 0.75 3.2 – – – – 3...12  A PKE12121721 1off PKE12PKE32 PKE-XTU-12121725 1off PKE12PKE32 PKE-XTUA-12121729 1off PKE12/XTU-12121733 1off 1.1 4.6 – – – – 1.5 6.3 3.6 3.3 – – 2.2 8.7 5 4.6 4 – 3 11.5 6.6 6 5.3 3.8 4 – 8.5 7.7 6.8 4.9 5.5 – 11.3 10.2 9 6.5 Start of delivery 05/2010 7.5 – – – – 8.8 2.2 8.7 – – – – 8...32  A PKE32121722 1off PKE32 PKE-XTU-32121726 1off PKE32 PKE-XTUA-32121730 1off PKE32/XTU-32121734 1off 3 11.5 – – – – 4 14.8 8.5 – – – 5.5 19.6 11.3 10.2 9 – 7.5 26.4 15.2 13.8 12.1 8.8 11 – 21.7 19.8 17.4 12.6 15 – 29.3 26.6 23.4 17 18.5 – – – 28.9 20.9 22 – – – – 23.8 Start of delivery 05/2010 30 – – – – 32 5.5 19.6 – – – – 16...65  A PKE65138258 1off PKE65 PKE-XTU-65138259 1off PKE65 PKE-XTUA-65138260 1off PKE65/XTU-65138516 1off 7.5 26.4 – – – – 11 38 21.7 19.7 17.4 – 15 51 29.3 26.6 23.4 17 18.5 63 36 32.9 28.9 20.9 22 – 41 37.4 33 23.8 30 – 55 50.3 44 32 37 – – 61.4 54 39 45 – – – 65 47 Start of delivery 07/2010 Start of delivery 10/2010 Start of delivery 10/2010 Start of delivery 10/2010 55 – – – – 58 2.2 8.7 – – – – 8...32  A PKE65138258 1off PKE65 PKE-XTUW-32138261 1off PKE65 PKE-XTUWA-32138262 1off PKE65/XTUW-32138517 1 off 3 11.5 – – – – 4 14.8 8.5 – – – 5.5 19.6 11.3 10.2 9 – 7.5 26.4 15.2 13.8 12.1 8.8 11 – 21.7 19.8 17.4 12.6 15 – 29.3 26.6 23.4 17 18.5 – – – 28.9 20.9 22 – – – – 23.8 Start of delivery 07/2010 Start of delivery 10/2010 Start of delivery 10/2010 Start of delivery 10/2010 30 – – – – 32 Notes Select switchgear and cables according to Class as shown in the table on page 6/22. 1)  For communications, module PKE-SWD-32 for contactors is required in addition,, → Page 1/14. Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking NA Certification Request filed for UL and CSA 7/9 PKE HPL07008EN PKE HPL07009EN

7/8 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Motor-protective circuit-breaker Standard auxiliary contacts Motor full-load current Basic device Trip module Standard Trip module Expanded 1) Motor-protective circuit-breakers StandardComplete device Motor rating AC-3 Setting rangeOverload releases Part no.Article no. See price list Std. pack usable  for Part no.Article no. See price list Std. pack usable  for Part no.Article no. See price list Std. pack Part no.Article no. See price list Std. pack 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V 660 V 690 V P I I I I I kW A A A A A Motor-protective circuit-breakers, type  “1” and type “2”  coordination 0.06 0.37 – – – – 0.3...1.2  A PKE12121721 1off PKE12 PKE-XTU-1,2121723 1off PKE12 PKE-XTUA-1,2121727 1off PKE12/XTU-1,2121731 1off 0.09 0.54 0.31 – – – 0.12 0.72 0.41 0.37 0.33 – 0.18 1.04 0.6 0.54 0.48 0.35 0.25 – 0.8 0.76 0.7 0.5 0.37 – 1.1 1.02 0.9 0.7 0.55 – – – – 0.9 Start of delivery 07/2010 Start of delivery 07/2010 Start of delivery 07/2010 0.75 – – – – 1.1 0.18 1.04 – – – – 1...4  A PKE12121721 1off PKE12 PKE-XTU-4121724 1off PKE12 PKE-XTUA-4121728 1off PKE12/XTU-4121732 1off 0.25 1.4 – – – – 0.37 2 1.1 1.02 – – 0.55 2.7 1.5 1.39 1.2 – 0.75 3.2 1.9 1.68 1.5 1.1 1.1 – 2.6 2.41 2.1 1.5 1.5 – 3.6 3.28 2.9 2.1 2.2 – – – 4 2.9 Start of delivery 05/2010 3 – – – – 3.8 0.75 3.2 – – – – 3...12  A PKE12121721 1off PKE12PKE32 PKE-XTU-12121725 1off PKE12PKE32 PKE-XTUA-12121729 1off PKE12/XTU-12121733 1off 1.1 4.6 – – – – 1.5 6.3 3.6 3.3 – – 2.2 8.7 5 4.6 4 – 3 11.5 6.6 6 5.3 3.8 4 – 8.5 7.7 6.8 4.9 5.5 – 11.3 10.2 9 6.5 Start of delivery 05/2010 7.5 – – – – 8.8 2.2 8.7 – – – – 8...32  A PKE32121722 1off PKE32 PKE-XTU-32121726 1off PKE32 PKE-XTUA-32121730 1off PKE32/XTU-32121734 1off 3 11.5 – – – – 4 14.8 8.5 – – – 5.5 19.6 11.3 10.2 9 – 7.5 26.4 15.2 13.8 12.1 8.8 11 – 21.7 19.8 17.4 12.6 15 – 29.3 26.6 23.4 17 18.5 – – – 28.9 20.9 22 – – – – 23.8 Start of delivery 05/2010 30 – – – – 32 5.5 19.6 – – – – 16...65  A PKE65138258 1off PKE65 PKE-XTU-65138259 1off PKE65 PKE-XTUA-65138260 1off PKE65/XTU-65138516 1off 7.5 26.4 – – – – 11 38 21.7 19.7 17.4 – 15 51 29.3 26.6 23.4 17 18.5 63 36 32.9 28.9 20.9 22 – 41 37.4 33 23.8 30 – 55 50.3 44 32 37 – – 61.4 54 39 45 – – – 65 47 Start of delivery 07/2010 Start of delivery 10/2010 Start of delivery 10/2010 Start of delivery 10/2010 55 – – – – 58 2.2 8.7 – – – – 8...32  A PKE65138258 1off PKE65 PKE-XTUW-32138261 1off PKE65 PKE-XTUWA-32138262 1off PKE65/XTUW-32138517 1 off 3 11.5 – – – – 4 14.8 8.5 – – – 5.5 19.6 11.3 10.2 9 – 7.5 26.4 15.2 13.8 12.1 8.8 11 – 21.7 19.8 17.4 12.6 15 – 29.3 26.6 23.4 17 18.5 – – – 28.9 20.9 22 – – – – 23.8 Start of delivery 07/2010 Start of delivery 10/2010 Start of delivery 10/2010 Start of delivery 10/2010 30 – – – – 32 Notes Select switchgear and cables according to Class as shown in the table on page 6/22. 1)  For communications, module PKE-SWD-32 for contactors is required in addition,, → Page 1/14. Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking NA Certification Request filed for UL and CSA 7/9 PKE HPL07008EN PKE HPL07009EN

7/10 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Standard auxiliary contacts 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Standard auxiliary contacts Contact configuration Contact sequence Circuit diagrams Connection method For use with Part no.Article no. Price See price list Std. pack Notes Notes Information relevant for export to North America N/O = normally open contact NC = normally closed contact Standard auxiliary contacts For motor-protective circuit-breakers 1 N/O 1 NC Screw terminals PKZM01PKZM0PKZM4PKZM0-TPKM0PKE 1) NHI11-PKZ0072896 5 off Can be fitted to the right side of: motor-protective circuit-breakers, transformer protective circuit breakers and motor-protective circuit-breakers for starter combinations Can be combined with:Trip-indicating auxiliary contact AGM, NHI-E-… Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified 1 N/O 1 NC Spring-loaded terminals NHI11-PKZ0-C229680 1 N/O 2 NC Screw terminals NHI12-PKZ0072895 2 N/O 1 NC Screw terminals NHI21-PKZ0072894 1 N/O 1 NC Screw terminals NHI-E-11-PKZ0082882 Can be fitted to motor-protective circuit-breakers, transformer-protective circuit-breakers and motor-protective circuit-breakers for starter combinations from serial number 01.45 mm (PKZM0 and PKZM01) or 55 mm (PKZM4) widths of the motor-protective circuit-breakers remain unchanged.NHI-E...-PKZ0-C not for use with MSC...-type motor starter combinations. 1 N/O – Screw terminals NHI-E-10-PKZ0082884 1 N/O – Spring-loaded terminals NHI-E-10-PKZ0-C229681 – 1 NC Spring-loaded terminals NHI-E-01-PKZ0-C229682 5 off 1 N/O 1 NC Screw terminals NHI-B-11-PKZ0208277 5 off Notes 1)  Only standard auxiliary contacts manufactured on or after CW 36/2009 are for use with PKE. NHI11 L1L2L3 1.14 1.22 1.13 1.21 I   Accessories 1 Motor-protective circuit-breakers → 7/4 5 Trip-indicating auxiliary contact → 7/12 Additional accessories → 7/20 1 5 5 1 NHI11 L1L2L3 1.14 1.22 1.13 1.21 I   L1L2L3 NHI12 1.13 1.14 1.22 1.21 1.31 1.32 I  L1L2L3 NHI21 1.13 1.21 1.33 1.14 1.22 1.34 I   L1L2L3 NHI-E-11 1.53 1.54 1.61 1.62 I   L1L2L3NHI-E-10 1.53 1.54 I    L1L2L3NHI-E-10 1.53 1.54 I    L1L2L3NHI-E-01 1.51 1.52 I   NHI-B-11 L1L2L3 1.14 1.22 1.13 1.21 I   7/11 NHI...-PKZ0... HPL07010EN NHI...-PKZ0... HPL07011EN

7/10 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Standard auxiliary contacts 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Standard auxiliary contacts Contact configuration Contact sequence Circuit diagrams Connection method For use with Part no.Article no. Price See price list Std. pack Notes Notes Information relevant for export to North America N/O = normally open contact NC = normally closed contact Standard auxiliary contacts For motor-protective circuit-breakers 1 N/O 1 NC Screw terminals PKZM01PKZM0PKZM4PKZM0-TPKM0PKE 1) NHI11-PKZ0072896 5 off Can be fitted to the right side of: motor-protective circuit-breakers, transformer protective circuit breakers and motor-protective circuit-breakers for starter combinations Can be combined with:Trip-indicating auxiliary contact AGM, NHI-E-… Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified 1 N/O 1 NC Spring-loaded terminals NHI11-PKZ0-C229680 1 N/O 2 NC Screw terminals NHI12-PKZ0072895 2 N/O 1 NC Screw terminals NHI21-PKZ0072894 1 N/O 1 NC Screw terminals NHI-E-11-PKZ0082882 Can be fitted to motor-protective circuit-breakers, transformer-protective circuit-breakers and motor-protective circuit-breakers for starter combinations from serial number 01.45 mm (PKZM0 and PKZM01) or 55 mm (PKZM4) widths of the motor-protective circuit-breakers remain unchanged.NHI-E...-PKZ0-C not for use with MSC...-type motor starter combinations. 1 N/O – Screw terminals NHI-E-10-PKZ0082884 1 N/O – Spring-loaded terminals NHI-E-10-PKZ0-C229681 – 1 NC Spring-loaded terminals NHI-E-01-PKZ0-C229682 5 off 1 N/O 1 NC Screw terminals NHI-B-11-PKZ0208277 5 off Notes 1)  Only standard auxiliary contacts manufactured on or after CW 36/2009 are for use with PKE. NHI11 L1L2L3 1.14 1.22 1.13 1.21 I   Accessories 1 Motor-protective circuit-breakers → 7/4 5 Trip-indicating auxiliary contact → 7/12 Additional accessories → 7/20 1 5 5 1 NHI11 L1L2L3 1.14 1.22 1.13 1.21 I   L1L2L3 NHI12 1.13 1.14 1.22 1.21 1.31 1.32 I  L1L2L3 NHI21 1.13 1.21 1.33 1.14 1.22 1.34 I   L1L2L3 NHI-E-11 1.53 1.54 1.61 1.62 I   L1L2L3NHI-E-10 1.53 1.54 I    L1L2L3NHI-E-10 1.53 1.54 I    L1L2L3NHI-E-01 1.51 1.52 I   NHI-B-11 L1L2L3 1.14 1.22 1.13 1.21 I   7/11 NHI...-PKZ0... HPL07010EN NHI...-PKZ0... HPL07011EN

7/12 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Auxiliary contacts, undervoltage releases 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Auxiliary contacts, undervoltage releases Auxiliary contacts, undervoltage releases Contact configuration Contact sequence Circuit diagrams For use with Part no.Article no. Price See price list Std. pack Notes Notes Information relevant for export to North America N/O = normally open contact NC = normally closed contact Trip indicators For motor-protective circuit-breakers 2 x 1 N/O – PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 1) AGM2-10-PKZ0072898 2 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified – 2 x 1 NC PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 1) AGM2-01-PKZ0072899 2 off Early-make auxiliary contacts For motor-protective circuit-breakers 2 N/O – – PKZM0PKZM0-TPKM0PKZM4 VHI20-PKZ0203595 2 off Can be fitted to front of motor-protective circuit-breaker, 45 mm width of the motor-protective circuit-breaker remains unchanged.For early energization of undervoltage release, e.g. in emergency switching off circuits to EN 60204.VHI20-PKZ0 cannot be used in combination with PKZ0-X(R). 2 N/O – – PKZM01 VHI20-PKZ01278495 5 off Shunt release (for power circuit-breakers) – – – PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 2) A-PKZ0(230V50HZ)073187 2 off Can be fitted to the left side of motor-protective circuit-breakers.Cannot be combined with:undervoltage release U-PKZ0DC: Intermittent operation 5 s – – – PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 2) A-PKZ0(24VDC)073200 2 off Undervoltage release – – – PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 2) U-PKZ0(230V50HZ)073135 2 off Can be fitted to the left side of motor-protective circuit-breakers.Cannot be combined with:A-PKZ0 shunt releaseWhen combined with circuit-breaker, can be used as emergency switching off device to IEC/EN 60204. Current limiters For increasing switching capacity of motor-protective circuit-breakers without auto-protection– – – – PKZM0PKZM4PKE CL-PKZ0082881 1 off Max. rated operating voltage U e = 690 V, rated  uninterrupted current I u   = 63 A Can be used for individual and group protection.For group protection and in combination with PKZM4, order additional BK25/3 incoming terminal if required.Mounting next to or behind the motor-protective circuit-breaker.PKZM4: 16 - 63 A: 100 kA/400 VPKZM4: 16 - 63 A: 10 kA/690 V Notes 1)  Only AGM2-...-PKZ0 manufactured on or after 06/2009 can be fitted. 2)  Only A(U)-PKZ0...  with serial number 02 or higher can be fitted. L1L2L3 "+" "I " Einschalten/Ausschalten L1L2L3 "+" "I " Auslösen "+" I  "+" 4.43 4.13 "I  " 4.44 4.14 Can be fitted to the right side of motor-protective circuit-breakers  Can be combined with:Standard auxiliary contactsNHI11-PKZ0NHI12-PKZ0NHI21-PKZ0NHI-E-… Separate indication of:a) General trip indication (overload)b) Short-circuit trip Local short-circuit indication by red indicator, manually resettable. Accessories Page 1 Motor-protective circuit-breakers → 7/43 Standard auxiliary contacts → 7/10 1 3 3 1 L1L2L3 "+" "I " Einschalten/Ausschalten L1L2L3 "+" "I " Auslösen "+" 4.21 "I  " "+" 4.31 4.32 4.22 I  3.13 3.23 3.14 3.24 I   C1 C2 Accessories Page 1 Motor-protective circuit-breakers → 7/4 Further actuating voltages  → 7/29 1 1 U  D1 D2 L T I   7/13 AGM2...., VHI... HPL07012EN AGM2...., VHI... HPL07013EN

7/12 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Auxiliary contacts, undervoltage releases 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Auxiliary contacts, undervoltage releases Auxiliary contacts, undervoltage releases Contact configuration Contact sequence Circuit diagrams For use with Part no.Article no. Price See price list Std. pack Notes Notes Information relevant for export to North America N/O = normally open contact NC = normally closed contact Trip indicators For motor-protective circuit-breakers 2 x 1 N/O – PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 1) AGM2-10-PKZ0072898 2 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified – 2 x 1 NC PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 1) AGM2-01-PKZ0072899 2 off Early-make auxiliary contacts For motor-protective circuit-breakers 2 N/O – – PKZM0PKZM0-TPKM0PKZM4 VHI20-PKZ0203595 2 off Can be fitted to front of motor-protective circuit-breaker, 45 mm width of the motor-protective circuit-breaker remains unchanged.For early energization of undervoltage release, e.g. in emergency switching off circuits to EN 60204.VHI20-PKZ0 cannot be used in combination with PKZ0-X(R). 2 N/O – – PKZM01 VHI20-PKZ01278495 5 off Shunt release (for power circuit-breakers) – – – PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 2) A-PKZ0(230V50HZ)073187 2 off Can be fitted to the left side of motor-protective circuit-breakers.Cannot be combined with:undervoltage release U-PKZ0DC: Intermittent operation 5 s – – – PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 2) A-PKZ0(24VDC)073200 2 off Undervoltage release – – – PKZM0PKZM4PKZM0-TPKM0PKZM01PKE 2) U-PKZ0(230V50HZ)073135 2 off Can be fitted to the left side of motor-protective circuit-breakers.Cannot be combined with:A-PKZ0 shunt releaseWhen combined with circuit-breaker, can be used as emergency switching off device to IEC/EN 60204. Current limiters For increasing switching capacity of motor-protective circuit-breakers without auto-protection– – – – PKZM0PKZM4PKE CL-PKZ0082881 1 off Max. rated operating voltage U e = 690 V, rated  uninterrupted current I u   = 63 A Can be used for individual and group protection.For group protection and in combination with PKZM4, order additional BK25/3 incoming terminal if required.Mounting next to or behind the motor-protective circuit-breaker.PKZM4: 16 - 63 A: 100 kA/400 VPKZM4: 16 - 63 A: 10 kA/690 V Notes 1)  Only AGM2-...-PKZ0 manufactured on or after 06/2009 can be fitted. 2)  Only A(U)-PKZ0...  with serial number 02 or higher can be fitted. L1L2L3 "+" "I " Einschalten/Ausschalten L1L2L3 "+" "I " Auslösen "+" I  "+" 4.43 4.13 "I  " 4.44 4.14 Can be fitted to the right side of motor-protective circuit-breakers  Can be combined with:Standard auxiliary contactsNHI11-PKZ0NHI12-PKZ0NHI21-PKZ0NHI-E-… Separate indication of:a) General trip indication (overload)b) Short-circuit trip Local short-circuit indication by red indicator, manually resettable. Accessories Page 1 Motor-protective circuit-breakers → 7/43 Standard auxiliary contacts → 7/10 1 3 3 1 L1L2L3 "+" "I " Einschalten/Ausschalten L1L2L3 "+" "I " Auslösen "+" 4.21 "I  " "+" 4.31 4.32 4.22 I  3.13 3.23 3.14 3.24 I   C1 C2 Accessories Page 1 Motor-protective circuit-breakers → 7/4 Further actuating voltages  → 7/29 1 1 U  D1 D2 L T I   7/13 AGM2...., VHI... HPL07012EN AGM2...., VHI... HPL07013EN

7/14 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories for motor-protective circuit-breakers in enclosures 2010 CA08103002Z-EN www.eaton.com Engineering Enclosure Accessories Part no. Part no. Degree of protection Handle color NHI..-PKZ0 AGM2-..-PKZ0 NHI-E..-PKZ0 VHI..-PKZ0 VHI..-PKZ01 U-PKZ0orA-PKZ0 L-PKZ0 Surface mounting enclosure Motor-protective circuit-breaker PKZM01 CI-PKZ01 IP40 – – – ● – – ● ● – – – – ● ● ● ● – ● – – – ● ● – – – ● – ● CI-PKZ01-G IP65 – – – ● – – ● ● – – – – ● ● ● ● – ● – – – ● ● – – – ● – ● CI-PKZ01-PVTCI-PKZ01-PVS IP65 Red-yellow – – ● – – ● ● – – – – ● ● ● CI-PKZ01-SVB IP65 – – – ● – – ● ● CI-PKZ01-SVB-V IP65 – – – – – K 1) ● ● Motor-protective circuit-breaker PKZM0 CI-K2-PKZ0 IP41 – ● – ● – – ● ● – ● ● – – ● ● CI-K2-PKZ0-G IP65 Black ● – ● – – ● ● – ● ● – – ● ● CI-K2-PKZ0-GR  IP65 Red-yellow ● – ● – – ● ● – ● ● – – ● ● CI-PKZ0-M IP40 – ● – ● – – – ● – – ● – – ● ● CI-PKZ0-GM IP55 Black ● – ● – – – ● – – ● – – ● ● CI-PKZ0-GRM IP55 Red-yellow ● – ● – – – ● – – ● – – ● ● Motor-protective circuit-breaker PKZM0 + early-make auxiliary contact VHI-PKZ0 CI-K2-PKZ0-GV IP65 Black ● – – ● – ● ● – ● – ● – ● ● CI-K2-PKZ0-GRV IP65 Red-yellow ● – – ● – ● ● – ● – ● – ● ● CI-K2-PKZ0-GVM  IP55 Black ● – – ● – – ● – – – ● – ● ● CI-K2-PKZ0-GRVM IP55 Red-yellow ● – – ● – – ● – – – ● – ● ● Notes The combination possibilities of circuit-breakers in an enclosure with accessory modules are identified by a  ● 1)  Always required PKZM01, PKZM

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE 2010 CA08103002Z-EN www.eaton.com 7/15 Enclosure Accessories Part no. Part no. Degree of protection Handle color NHI..-PKZ0 AGM2-..-PKZ0 NHI-E..-PKZ0 VHI..-PKZ0 VHI..-PKZ01 U-PKZ0orA-PKZ0 L-PKZ0 Surface mounting enclosure Motor-protective circuit-breaker PKZM4 CI-K4-PKZ4-G IP65 Black ● ● ● – – ● ● ● ● – ● – ● ● CI-K4-PKZ4-GR IP65 Red-yellow ● ● ● – – ● ● ● ● – ● – ● ● Installation enclosure Motor-protective circuit-breaker PKZM01 E-PKZ01 IP40 – – – ● – – ● ● – – – – ● ● ● ● – ● – – – ● ● – – – ● – ● E-PKZ01-G IP65 – – – ● – – ● ● – – – – ● ● ● ● – ● – – – ● ● – – – ● – ● E-PKZ01-PVTE-PKZ01-PVS IP65 Red-yellow – – ● – – ● ● – – – – ● ● ● E-PKZ01-SVB IP65 – – – ● – – ● ● E-PKZ01-SVB-V IP65 – – – – – K 1) ● ● Motor-protective circuit-breaker PKZM0 E-PKZ0 IP40 – ● – – – – – ● – – – – – ● ● E-PKZ0-G IP55 Black ● – ● – – – ● – – ● – – ● ● E-PKZ1-GR IP55 Red-yellow ● – ● – – – ● – – ● – – ● ● Notes The combination possibilities of circuit-breakers in an enclosure with accessory modules are identified by a  ● 1)  Always required PKZM4, PKZM01, PKZM0

7/16 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Insulated enclosure 2010 CA08103002Z-EN www.eaton.com Insulated enclosure Degree of protection For use with Part no.Article no. Price See price list Std. pack Notes Insulated enclosures for surface mounting For Motor-protective circuit-breaker PKZM01s – IP40 PKZM01+NHI-E or VHI-PKZ01+U or A or NHI+L (2 off) CI-PKZ01281403 1 off Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom. With operating membrane IP65 CI-PKZ01-G281404    Lockable in Off position IP65 PKZM01+NHI-E or +U or A+L (2 off) CI-PKZ01-SVB281405    Lockable in Off position in combination with VHI-PKZ01 IP65 CI-PKZ01-SVB-V281944    With emergency switching off mushroom button, maintained IP65 CI-PKZ01-PVT281406    With emergency switching off mushroom button, with key-release IP65 CI-PKZ01-PVS281407    For extension with inserts CI/E-PKZ01-X... unit As insert PKZM01 CI-PKZ01-X289934    For Motor-protective circuit-breakers PKZM0 Cover with aperture dimensioned to accommodate front of breaker. IP40, when mounted turned through 90° to left/right IP41 with verti-cal mount-ing PKZM0-… +NHI or AGM+U or A+NHI-E+L-PKZ0 (2 off) CI-K2-PKZ0219653 1 off M25 metric cable entry knockout, top and bottomCable push-through membrane top, bottom, in the back plate and as a control line entry.Insulated enclosure CI-K2 incl. N and PE terminal. With black-grey rotary knob IP65 CI-K2-PKZ0-G219654    With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP65 CI-K2-PKZ0-GR219655    Cover with aperture dimensioned to accommodate front of breaker IP40 PKZM0-…+NHI or U or A+L-PKZ0 (2 off) CI-PKZ0-M267083    Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom. With black-grey rotary knob IP55 PKZM0-…+NHI-E+NHI or U or A+L-PKZ0 (2 off) CI-PKZ0-GM260089    With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP55 CI-PKZ0-GRM260104    For Motor-protective circuit-breakers PKZM0 with early-make VHI auxiliary contacts With black-grey rotary knob IP65 PKZM0-... and VHI+NHI or AGM+U or A+L (2 off) CI-K2-PKZ0-GV219657 1 off M25 metric cable entry knockout, top and bottomCable push-through membrane top, bottom, in the back plate and as a control line entry.Insulated enclosure CI-K2 incl. N and PE terminal. With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP65 CI-K2-PKZ0-GRV219656    With black-grey rotary knob IP55 PKZM0-... and VHI+U or A (undervolt-age or shunt release)+L-PKZ0 (2 off) CI-PKZ0-GVM263526    Integrated terminal for PE(N) con-nection,  two M25 cable entry knockouts at top and at bottom. With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP55 CI-PKZ0-GRVM263525    For Motor-protective circuit-breakers PKZM4 With black-grey rotary knob IP65 PKZM4-…+VHI or NHI-E+NHI and AGM+U or A+L-PKZ0 (2 off) CI-K4-PKZ4-G225524 1 off Metric knockout:Top and bottom: M25/M32In the back plate: M25/M32Control cable entry: M20CI-K4 insulated enclosure including insulated PE terminal With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP65 CI-K4-PKZ4-GR225525    PKZM01, PKZM0, PKZM4 HPL07016EN

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Insulated enclosure 2010 CA08103002Z-EN www.eaton.com 7/17 Insulated enclosure Degree of protection For use with Part no.Article no. Price See price list Std. pack Information relevant for export to North America Insulated enclosures for flush mounting For Motor-protective circuit-breaker PKZM01sIntegrated terminal for PE(N) connection. Front IP40 PKZM01+NHI or U or A+NHI-E or VHI+L (2 off) E-PKZ01281633 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified With operating membrane Front IP65 E-PKZ01-G281634 1 off Lockable in Off position Front IP65 PKZM01+U or A+NHI-E E-PKZ01-SVB281635 1 off Lockable in Off position, in combina-tion with VHI-PKZ01 Front IP65 PKZM01+U or A+NHI-E or VHI  E-PKZ01-SVB-V281943 1 off With emergency switching off mushroom button, maintained Front IP65 E-PKZ01-PVT281636 1 off With emergency switching off mushroom button, with key-release Front IP65 E-PKZ01-PVS281637 1 off For extension with inserts CI/E-PKZ01-X... unit As insert PKZM01 E-PKZ01-X289935 1 off For Motor-protective circuit-breakers PKZM0Integrated terminal for PE(N) connection. Cover with aperture dimensioned to accommodate front of breaker Front IP40 PKZM0-… +NHI or U or A +L-PKZ0 (2 parts) E-PKZ0072906 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified With black-grey rotary knob Front IP55 PKZM0-…+NHI or U or A+NHI-E+L-PKZ0 (2 parts) E-PKZ0-G072907 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Degree of Protection IEC: Front IP55, UL/CSA Type: 1, 12, 3R With red-yellow rotary knob, for use as emergency switching off device to EN 60204 Front IP55 E-PKZ0-GR072908 1 off E-PKZ

7/18 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Insulated enclosure 2010 CA08103002Z-EN www.eaton.com Insulated enclosures for surface mounting For Motor-protective circuit-breaker PKZM01sIntegrated terminal for PE(N) connection. IP41 PKZM01+NHI-E or VHI-PKZ01+U or A or NHI+L (2 off) CI-PKZ01-NA281408 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Specially designed for NA✓Degree of Protection IEC: IP41, UL/CSA Type: - With operating membrane IP65 PKZM01+NHI-E or VHI-PKZ01+U or A or NHI+L (2 off) CI-PKZ01-NA-G281409 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Specially designed for NA✓Degree of Protection IEC: IP65, UL/CSA Type: - Lockable in Off position IP65 PKZM01+NHI-E or VHI-PKZ01+U or A+L (2 off) CI-PKZ01-NA-SVB281630 1 off Lockable in Off position, in combination with VHI-PKZ01 IP65 PKZM01+NHI-E+U or A+L (2 off) CI-PKZ01-NA-SVB-V281945 1 off With emergency switching off mushroom button, maintained IP65 CI-PKZ01-NA-PVT281631 1 off With emergency switching off mushroom button, with key-release IP65 CI-PKZ01-NA-PVS281632 1 off For Motor-protective circuit-breakers PKZM0Integrated N and PE terminals; lower section without knockouts With black-grey rotary knob IP55 PKZM0-…+NHI or U or A+NHI-E+L-PKZ0 (2 parts) CI-K2-PKZ0-NA-G262680 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Specially designed for NA✓Degree of Protection IEC: IP55, UL/CSA Type: 1, 12, 3R With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP55 CI-K2-PKZ0-NA-GR262681 1 off For Motor-protective circuit-breakers PKZM0 with early-make auxiliary contactsIntegrated N and PE terminals; lower section without knockouts With black-grey rotary knob IP55 PKZM0-…+VHI… + U…+L-PKZ0 (2 parts) CI-K2-PKZ0-NA-GV262682 1 off With red-yellow rotary knob, for use as emergency switching off device to EN 60204 IP55 CI-K2-PKZ0-NA-GRV262683 1 off Degree of protection For use with Part no.Article no. Price See price list Std. pack Information relevant for export to North America CI-PKZ

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Insulated enclosure 2010 CA08103002Z-EN www.eaton.com 7/19 Insulated enclosure Degree of protection For use with Part no.Article no. PriceSee price list Std. pack Information relevant for export to North America Insulated enclosures, accessories Padlocking feature For up to 3 padlocks with 3 – 6 mm hasp thickness, for use as main switch to IEC/EN 60204 Lockable in the 0-position of the PKZM0 or Motor-protective circuit-breaker PKZM4. – CI-K2-PKZ0-G(R)(V)CI-PKZ0-G(R)(V)M SVB-PKZ0-CI035129 3 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified – – E-PKZ0-G(R) SVB-PKZ0-E035127 3 off – – CI-K4-PKZ4-G(R) SVB-PKZ4-CI225526 1 off Neutral terminal For connection of a 5th conductor Flexible, 1 - 4 mm 2 – CI-K2-PKZ0-... K-CI-K1/2207451 20 off UL/CSA certification not required 63 A, flexible, 6 - 16 mm² – CI-K4-PKZ4-G(R) K25/1096200 10 off – – E-PKZ0(-G)(-GR)E-PKZ01(-G) N-PKZ0082160 20 off Units for insulated enclosures for PKZ01 Combinable with CI‐PKZ01‐X and E‐PKZ01‐X. With operating membrane Front IP65 PKZM01+NHI-E or VHI-PKZ01+U or A or NHI+L (2 off) CI/E-PKZ01-XG289936 1 off Lockable in Off position PKZM01+NHI-E+U or A+L (2 off) CI/E-PKZ01-XSVB289939 With emergency switching off mushroom button, maintained PKZM01+NHI-E or VHI-PKZ01+U or A+L (2 off) CI/E-PKZ01-XPVT289937 With emergency switching off mushroom button, with key-release PKZM01+NHI-E or VHI-PKZ01+U or A+L (2 off) CI/E-PKZ01-XPVS289938 Lockable in Off position, in combination with VHI-PKZ01 PKZM01VHI-PKZ01+U or A+L (2 off) CI/E-PKZ01-XSVB-V289980 SVB-PKZ, CL/EPKZ01 HPL07019EN

7/20 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 2010 CA08103002Z-EN www.eaton.com Accessories Cable entry Drilling dimensions External cable diameter Part no.Article no. PriceSee price list Std. pack  mm  mm Metric cable glands to EN 50262 • With lock nut and built-in strain relief• IP68 up to 5 bar, halogen free M20 20.5 6 - 13 V-M20206910 20 off M25 25.5 9 - 17 V-M25206911 M32 32.5 13 - 21 V-M32206912 10 off M32 32.5 18 - 25 V-M32G226156 Metric diaphragm grommets • IP66• With integral push-through diaphragm M20 20.5 1 - 13 KT-M20207602 100 off M25 25.5 1 - 18 KT-M25207603 M32 32.5 1 - 25 KT-M32207604 For use with Part no.Article no. PriceSee price list Std. pack Notes Door coupling handles Degree of protection IP65,  UL/CS Type 4X / Type12 For use as main switch to IEC/EN 60204 Black PKZM0PKZM4 PKZ0-XH 1) 106132 1 off Pluggable PKZ0-XAH extension shaft, can be cut to any required length for installation depths of 100…240 mm. Follower included in delivery.With ON/OFF switch position and “+” (tripped), lockableWith 3 padlocks, 4 – 8 mm hasp. Cannot be used in combination with VHI20-PKZ0. For use as a main switch with emergency switching off function to EN 60204 Red-yellow PKZM0PKZM4 PKZ0-XRH 1) 106133 For use as a main switch to EN 60204 in MCC power distribution systems and with PKZM0 installed rotated by 90° Black PKZM0PKZM4 PKZ0-XH-MCC 1) 106136 For use as a main switch with emergency switching off function to EN 60204 in MCC power distribution systems and with PKZM0 installed rotated by 90° Red-yellow PKZM0PKZM4 PKZ0-XRH-MCC 1) 106137 For use as main switch to IEC/EN 60204 Black PKE PKE-XH 1) 142416 1 off Pluggable PKZ0-XAH extension shaft, can be cut to any required length for installation depths of 100…240 mm. Follower included in delivery.With ON/OFF switch position and “+” (tripped), lockableWith 3 padlocks, 4 – 8 mm hasp.  For use as a main switch with  emergency switching off function to EN 60204 Red-yellow PKE PKE-XRH 1) 142417 For use as a main switch to EN 60204 in MCC power distribution systems and with PKE installed rotated by 90° Black PKE PKE-XH-MCC 1) 142418 For use as a main switch with emergency- switching off function to EN 60204 in MCC power distribution systems and with PKE installed rotated by 90° Red-yellow PKE PKE-XRH-MCC 1) 142419 Clamp cover For increasing the degree of protection of the PKZM4 to IP2X – PKZM4 HB-PKZ4 2) 256581 1 off Suitable for connecting cables with a max. external diameter of 9.5 mm Pluggable extension shaft – – – PKZM0PKZM4 PKZ0-XAH 1) 106134 1 off Follower not included Information relevant for export to North America 1) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Degree of Protection IEC: IP65, UL/CSA Type: 4X, 12 2) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified HPL07020EN

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 2010 CA08103002Z-EN www.eaton.com 7/21 Accessories Notes Part no.Article no. PriceSee price list Std. pack Information relevant for export to North America Telescopic adapters With 45 mm top-hat rail to IEC/EN 60715 for compensation of the mounting depth of rear-mounted devices enclosures CI-K and cabinets Telescopic clip Stepless adjustment via scale from 75 – 115 mm. M22-TA226161 1 off Product Standards IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 012528 CSA Class No. 3211-03 NA Certification UL Listed, CSA certified Lockable rotary handle For locking motor-protective circuit-breakers PKZM0, PKZM4 and PKE as a main switch in compliance with EN 60204.Can be padlocked in the “0” position.Hasp thickness: 3 – 6.35 mm Can not be combined with VHI-PKZ0. AK-PKZ0030851 5 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Holding facility To prevent tampering with the overload release and the test function, it can be sealed using industry standard sealing wireFor use with motor-protective circuit-breakers PKZM0 and PKZM4 – PL-PKZ0203599 5 off Mounting angle bracket For screw fixing to mounting plate – PKE32-XMB134837 20 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking NA Certification Request filed for UL and CSA Documentation Motor-protective circuit-breakers PKZM0, overload monitoring of EEx e motors German/English AWB1210-1458D/GB266164 1 off Motor-protective circuit-breakers PKZM4, overload monitoring of  EEx e motors German/English AWB1210-1457D/GB266165 Motor-protective circuit-breakers PKE, EEx electric motor overload monitoring German/English AWB1210-1631DE/EN134836 For use with Color Voltage Part no.Article no. PriceSee price list Std. pack U s V Indicator lights with glow lamp CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) White 110 - 230 L-PKZ0(230V)082151 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) White 230 - 400 L-PKZ0(400V)082152 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) White 415 - 500 L-PKZ0(500V)082153 5 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Green 110 - 230 L-PKZ0-GN(230V)082154 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Green 230 - 400 L-PKZ0-GN(400V)082155 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Green 415 - 500 L-PKZ0-GN(500V)082156 5 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Red 110 - 230 L-PKZ0-RT(230V)082157 10 off CI-K2-PKZ0-… , CI-K4-PKZ4 , CI-PKZ0(1) , E-PKZ0(1) Red 230 - 400 L-PKZ0-RT(400V)082158 10 off HPL07021EN

7/22 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Busbar adapters 2010 CA08103002Z-EN www.eaton.com Busbar adapters Rated operational voltage Conductor cross-section Adapter width Mounting rails For use with Part no.Article no. PriceSee price list Std. pack Notes U e V  mm Number Busbar adapters for PKZ and PKE Approved to UL 508.For fitting to flat copper busbars with 60 mm between busbar centers, suitable for 5 mm and 10 mm busbar thickness. Rated operational current 16 A For starters with spring-loaded terminals 690 AWG 14(2.5 mm²) 45 2 PKZM0-C + DILMC7PKZM0-C + DILMC9PKZM0-C + DILMC12 BBA0C-16101455 4 off According to UL 508: I e = 12 A Rated operational current 25 A For reversing starters 690 AWG 12(4 mm²) 90 1 PKZM0, PKE + 2 x DILM7-01PKZM0, PKE + 2 x DILM9-01PKZM0, PKE + 2 x DILM12-01MSC-R-0,25-M7… - MSC-R-12-M12… BBA0R-25101453 2 off In combination with individual components PKZM0 and DILM, use reversing starter kit PKZM0-XRM12.Fully assembled and tested combination with MSC-R → Page 8/20Only busbar adapters/wiring sets manufactured on or after CW35/2009 can be used for PKE. Can be used universally 690 AWG 12(4 mm²) 45 2 – BBA0-25/2TS101481 4 off Mounting rails can be moved within 1.25 mm grid. For DOL starters 690 AWG 12(4 mm²) 45 1 PKZM0, PKE + 2 x DILM17-01PKZM0, PKE + 2 x DILM25-01PKZM0, PKE + 2 x DILM25-01PKZM0, PKE +2 x DILM32-01MSC-R-16-M17… MSC-R-32-M32… BBA0-25101451 4 off In combination with individual components PKZM0 and DILM, use DOL starter kit PKZM0-XRM12.Fully assembled and tested combination with MSC-D → Page 8/2Only busbar adapters/wiring sets manufactured on or after CW35/2009 can be used for PKE. For soft starters 690 AWG 12(4 mm²) 45 1 PKZM0, PKE + DS7...004N...PKZM0, PKE + DS7...007N...PKZM0, PKE + DS7...009N...PKZM0, PKE + DS7...012N... BBA0L-25142526 1 off – Rated operational current 32 A For reversing starters 690 AWG 10(6 mm²) 90 3 PKZM0, PKE + 2 x DILM17-01PKZM0, PKE + 2 x DILM25-01PKZM0, PKE + 2 x DILM32-01MSC-R-16-M17… - MSC-R-32-M32… BBA0R-32101454 2 off In combination with single components PKZM0 and DILM, wiring kit PKZM0-XM32DE and reversing starter wiring kit DILM32-XRL can be used.Fully assembled and tested combination with MSC-R → Page 8/20Only busbaradapters/wiring sets manufactured on or after CW 35/2009 can be used for PKE. Information relevant for export to North America Product Standards UL 508A; CSA-C22.2 No. 14; IEC60439-1; CE marking UL File No. E300273 UL CCN NMTR, NMTRZ CSA File No. 232140 CSA Class No. 3211-37 NA Certification UL Listed, CSA  certified Max. Voltage Rating 600 V AC BBA HPL07022EN

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Busbar adapters 2010 CA08103002Z-EN www.eaton.com 7/23 Rated operational current 32 A Can be used universally. 690 – 45 2 PKZM0…, PKE +DILM… BBA0-32/2TS-C 2) 116708 4 off Universal adapter 1-, 2- and 3-phase applications.Mounting rail can be moved within 1.25 mm grid.For conductor cross-sections, round conductors of up to 6 mm 2 . Only busbaradapters/wiring sets manufactured on or after CW 35/2009 can be used for PKE. For DOL starters. 690 AWG 10(6 mm²) 45 2 PKZM0, PKE + DILM17PKZM0, PKE + DILM25PKZM0, PKE + DILM32MSC-D-16-M17… - MSC-D-32-M32… BBA0-32 1) 101452 4 off In combination with individual components PKZM0 and DILM wiring kit PKZM0-XM32DE can be used.Fully assembled and tested combination with MSC-D → Page 8/2Only busbar adapters/wiring sets manufactured on or after CW35/2009 can be used for PKE. For soft starters 690 AWG 10(6 mm²) 45 2 PKZM0, PKE + DS7...016N...PKZM0, PKE + DS7...024N...PKZM0, PKE + DS7...032N... BBA0L-32142527 1 off – For 160 mm adapter system with motor-protective circuit-breakers – 690 AWG  10(6 mm²) 45 1 PKZM0, PKE BBA0K-32142528  1 off – Rated operational current 63 AFor DOL starters. 690 AWG 8(10 mm²) 55 2 PKZM4 + DILM17PKZM4 + DILM25PKZM4 + DILM32PKZM4 + DILM40PKZM4 + DILM50PKZM4 + DILM65 BBA4L-63 1) 101459  4 off The following can be used to establish an electrical connection: For PKZM4 + DILM17 to DILM32: MVS-LB0-0M-GFor PKZM4 + DILM40 to DILM65:PKZM4-XM65DE. 690 AWG 8(10 mm²) 72 2 PKZ2 + DILM7PKZ2 + DILM9PKZ2 + DILM12PKZ2 + DILM15PKZ2 + DILM17PKZ2 + DILM25PKZ2 + DILM32PKZ2 + DILM40 BBA2L-63 1) 101480  4 off The following can be used to establish an electrical connection: For PKZ2 + DILM7 to DILM12: MVS-LB0-00M-GFor PKZ2 + DILM15 to DILM32:MVS-LB0-0M-G. For motor-protective circuit-breakers 690 AWG 8(10 mm²) 54 1 PKZM4  BBA4-63 1) 101457  4 off – 690 AWG 8(10 mm²) 72 1 PKZ2 BBA2-63 1) 101458  4 off – Information relevant for export to North America 1) 2) Product Standards UL 508A; CSA-C22.2 No. 14; IEC60439-1; CE marking UL File No. E300273 UL CCN NMTR, NMTR7 CSA File No. 232140 CSA Class No. 3211-37 NA Certification UL Listed, CSA  certified Max. Voltage Rating 600 V AC Product Standards UL 508A; CSA-C22.2 No. 14; IEC60439-1; CE marking UL File No. E300273 UL CCN NMTR, NMTR7 NA Certification UL Listed, CSA  certified Max. Voltage Rating 600 V AC Rated operational voltage Conductor cross-section Adapter width Mounting rails For use with Part no.Article no. PriceSee price list Std. pack Notes U e V  mm Number BBA HPL07023EN

7/24 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Busbar adapters 2010 CA08103002Z-EN www.eaton.com Without electrical contacts Empty module. – – 45 2 – BBA0/2TS-L 1) 101482 4 off Mounting rails can be moved within a 1.25 mm grid.Can be used to mount reversing and star-delta starters. – – 54 2 – BBA4/2TS-L 1) 101483 4 off Mounting rails can be moved within a 1.25 mm grid.Can be used to mount reversing and star-delta starters. Side-mounted module, can be attached on both sides. – – 9 – – BBA-XSM 1) 101484 10 off Can be grouped with busbar adapt-ers in order to extend the mounting width. Busbar adapters accessories Mounting rails – – 45 – BBA… PKZM0-XMR 2) 239364 10 off – – – 54 – BBA… PKZM0-XMR54 2) 113911 10 off – – – 72 – BBA… PKZM0-XMR72 2) 113912 10 off – Connecting cable – – – – – BBA… BBA-XLT-6-130 3) 116902 30 off – – – – – – BBA… BBA-XLT-16-142 3) 116903 30 off – Information relevant for export to North America 1) 2) Product Standards UL 508A; CSA-C22.2 No. 14; IEC60439-1; CE marking UL File No. E300273 UL CCN NMTR, NMTR7 CSA File No. 232140 CSA Class No. 3211-37 NA Certification UL Listed, CSA  certified Max. Voltage Rating 600 V AC Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E300273 UL CCN NMTR, NMTR7 CSA File No. 232140 CSA Class No. 3211-37 NA Certification UL Listed, CSA certified 3) Product Standards UL 508A; CSA-C22.2 No. 14; IEC60439-1; CE marking UL File No. On request UL CCN On request CSA File No. On request CSA Class No. On request NA Certification UL Recognized, CSA certified Rated operational voltage Conductor cross-section Adapter width Mounting rails For use with Part no.Article no. PriceSee price list Std. pack Notes U e V  mm Number BBA, PKZM0-XM HPL07024EN

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Wiring sets 2010 CA08103002Z-EN www.eaton.com 7/25 Wiring sets For use with Part no.Article no. PriceSee price list Std. pack Notes Wiring set DOL starter PKZM0, PKE + DILM7PKZM0, PKE + DILM9PKZM0, PKE + DILM12PKZM0, PKE + DILM15DS7-34…SX004…DS7-34…SX007…DS7-34…SX009…DS7-34…SX012… PKZM0-XDM12283149 1 off Consists of:• Mechanical connection element for PKZM0 and contactor• Main supply wiring between PKZM0 and contactor  with tool-less plug connection • Cable routingAs auxiliary contact, use DILA-XHIT... → Page 5/40Cannot be combined with NHI‐E…PKZ0‐C.U e  ≦ 415 V  1) PKZM0, PKE + DILM17PKZM0, PKE + DILM25PKZM0, PKE + DILM32 PKZM0-XDM32283153 1 off Consists of:• Top-hat rail adapter plates• Power supply wiring between PKZ and contactor 1) PKZM4 + DILM40PKZM4 + DILM50PKZM4 + DILM65 PKZM4-XDM65101053 1 off Reversing starters PKZM0, PKE + DILM7-01PKZM0, PKE + DILM9-01PKZM0, PKE + DILM12-01 PKZM0-XRM12283185 1 off Consists of:• Mechanical connection element for PKZM0 and contactor• Reversing starters main supply wiring with tool-less plug connection• Control cables for electrical interlocking in tool-less plug connection: – K1M: A1 -K2M: 21– K1M: 21 -K2M: A1– K1M: A2 -K2M: A2 • Cable routing As auxiliary contact DILA‐XHIT...use → Page 5/40Can not be combined with AGM‐PKZ0.U e  ≦ 415 V 1) PKZM0, PKE + DILM17PKZM0, PKE + DILM25PKZM0, PKE + DILM32 PKZM0-XRM32283189 1 off Consists of:• Top-hat rail adapter plates• Reversing starters supply wiring 1) Wiring kit PKZM0, PKE + DILM17PKZM0, PKE + DILM25PKZM0, PKE + DILM32DS7-34…SX016…DS7-34…SX024…DS7-34…SX032… PKZM0-XM32DE239349 5 off • Main supply wiring between PKZM0 and contactor• Use only in combination with busbar adapter or mounting rail adapter  plate PKZM4 + DILM40PKZM4 + DILM50PKZM4 + DILM65 PKZM4-XM65DE101056 5 off • Main current supply between PKZM4 and contactor Top-hat rail adapter plates PKZM0-XDM12PKZM0-XRM12 PKZM0-XC45283132 4 off Consists of:• 45 mm wide adapter plate• Connection element for side-by-side positioning of further plates 1) PKZM4 + DILM40PKZM4 + DILM50PKZM4 + DILM65 PKZM4-XC55/2101054 4 off Consists of:• 55 mm wide adapter plate• Connection cam for additional plates• For use with reversing and start-delta starters 1) Soft starters PKZM0, PKE + DS7...004N...PKZM0, PKE + DS7...007N...PKZM0, PKE + DS7...009N...PKZM0, PKE + DS7...012N... PKZM0-XC45L142529  1 off Consists of:• 45 mm wide adapter plate PKZM0, PKE + DS7...016N...PKZM0, PKE + DS7...024N...PKZM0, PKE + DS7...032N... PKZM0-XC45L/2142570  1 off Consists of:• 45 mm wide adapter plate Notes 1)  Use only busbar adapters/wiring sets manufactured on or after CW35/2009 for PKE. Information relevant for export to North America 2) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified 3)UL/CSA certification not required 4) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E300273 UL CCN NMTR CSA File No. 232140 CSA Class No. 3211-37 NA Certification UL Listed, CSA certified PKZMO, PKZM4 HPL07025EN

7/26 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor feeder plugs, three-phase commoning links 2010 CA08103002Z-EN www.eaton.com Motor feeder plugs, three-phase commoning links Description For use with Part no.Article no. PriceSee price list Std. pack Notes Information relevant for export to North America Motor feeder plug PE module with contact plate DILM(C)7DILM(C)9DILM(C)12DILM(C)15 DILM12-XMCE121764 5 off 35 x 7.5 (15) mm mounting rail (as per DIN EN 60715) with PE function required.For connection of:PE 0.75 – 4 mm 2 Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking NA Certification Request filed for UL and CSA Motor feeder plug with PE module andcontact plate DILM(C)7DILM(C)9DILM(C)12DILM(C)15 DILM12-XMCP/E121769 1 off 35 x 7.5 (15) mm mounting rail (as per DIN EN 60715) with PE function required.For connection of:L1, L2, L3, PE 0.75 – 2.5 mm 2 Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking NA Certification Request filed for UL and CSA Motor feeder plug with PE module without contact plate PKZM0/PKE + DILM(C)7PKZM0/PKE + DILM(C)9PKZM0/PKE + DILM(C)12PKZM0/PKE + DILM(C)15MSC-D(E)-…-M7…MSC-D(E)-…-M9…MSC-D(E)-…-M15… DILM12-XMCP/T121770 1 off For connection of:L1, L2, L3, PE 0.75 – 2.5 mm 2 Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking NA Certification Request filed for UL and CSA Circuit-breakers Length Unit width Part no.Article no. PriceSee price list Std. pack Notes Number  mm  mm Three-phase commoning links, incoming unit via terminals 1,  3, and 5 Finger- and back-of-hand-proof, short-circuit proof, U e =690 V, I u =63 A Can be extended through rotated  installation For PKZM0-... or PKE without side-mounted auxiliary contacts or voltage releases 2 90 45 B3.0/2-PKZ0 1) 063961 10 off For parallel feeding of multiple motor-protective circuit-breakers on terminals 1,  3, and 5 3 135 45 B3.0/3-PKZ0 1) 232289 4 180 45 B3.0/4-PKZ0 1) 063960 5 225 45 B3.0/5-PKZ0 1) 232290 For motor-protective circuit-breakers with one auxiliary contact or trip-indicating auxiliary contact each fitted to right side 2 99 45 + 9 B3.1/2-PKZ0 1) 044945 10 off For parallel feeding of multiple motor-protective circuit-breakers on terminals 1,  3, and 5 3 153 45 + 9 B3.1/3-PKZ0 1) 044946 4 207 45 + 9 B3.1/4-PKZ0 1) 044947 5 261 45 + 9 B3.1/5-PKZ0 1) 044948 For PKZM0-... or PKE with one auxiliary contact or trip-indicating auxiliary contact each fitted to right side, or one voltage release fitted on left side 2 108 45 + 18 B3.2/2-PKZ0 1) 063963 10 off For parallel feeding of multiple motor-protective circuit-breakers on terminals 1,  3, and 5 4 234 45 + 18 B3.2/4-PKZ0 1) 063959 10 off Information relevant for export to North America 1) Product StandardsUL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE markingUL File No. E36332 UL CCN NLRV CSA File No. 98494 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified B3...PKZO, B3...PKZO-U HPL07026EN

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Incoming terminals 2010 CA08103002Z-EN www.eaton.com 7/27 Incoming terminals Circuit-breakers For use with Unit width Part no.Article no. PriceSee price list Std. pack Notes Number  mm Shroud for unused terminals Protection against direct contact.For covering unused terminals on three-phase commoning link B3...-PKZ0 – – – H-B3-PKZ0 1) 032721 20 off – Incoming terminals – PKZM0PKE – BK25/3-PKZ0 2) 032720 5 off For three-phase commoning link, protected against accidental contact, U e  = 690 V, I u  = 63 A  For conductor cross-sections: 2.5 - 25 mm 2  stranded 2.5 - 16 mm 2  flexible with ferrule AWG 14 - 6, usable on terminals 1,  3, and 5 – PKZM0 – BK25/3-PKZ0-E 3) 262518 5 off For three-phase commoning link, protected against accidental contact, U e = 690 V, I u = 60 A For conductor cross-sections:2.5 - 25 mm 2  stranded 2.5 - 16 mm 2  flexible with ferrule AWG 14 - 6For assembly of Type E starters. – PKZM4 – BK50/3-PKZ4-E 4) 272165 1 off Can be combined with three-phase commoning link B3…PKZ4.I u   = 120 A. For assembly of Type E starters. Information relevant for export to North America 1) 2) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 98494 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified 3) 4) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 98494 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified Specially designed for NA ✓Suitable for PKZM0/PKE, line terminal required for Type E/F applications Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified Specially designed for NA ✓Suitable for PKZM4/PKE, line terminal required for Type E/F applications HB3...PKZO, BK...I3-PKZ HPL07027EN

7/28 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Three-phase commoning links 2010 CA08103002Z-EN www.eaton.com Three-phase commoning links Circuit-breakers Length Unit width Part no.Article no. PriceSee price list Std. pack Information relevant for export to North America Number  mm  mm Three-phase commoning links Finger- and back-of-hand-proof, short-circuit proof U e = 690 V, I u = 128 A For PKZM4 without side-mounted auxiliary contacts or voltage releases 2 110 55 B3.0/2-PKZ4220220 1 off Product StandardsUL 508; CSA-C22.2 No. 14;  IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified 3 165 B3.0/3-PKZ4220221 4 220 B3.0/4-PKZ4220222 For PKZM4 with one auxiliary contact or trip-indicating auxiliary contact each fitted on the right side 2 119 55 + 9 B3.1/2-PKZ4220223 1 off 3 183 B3.1/3-PKZ4220224 4 247 B3.1/4-PKZ4220225 For PKZM4 with one auxiliary contact or trip-indicating auxiliary contact each fitted to right side, or one voltage release fitted to left side 2 128 55 + 18 B3.2/2-PKZ4220226 1 off 4 274 B3.2/4-PKZ4220227 Shroud for unused terminals Protection against direct contact.To cover unused terminals on three-phase commoning link – – – H-B3-PKZ4220228 10 off Product StandardsUL 508; CSA-C22.2 No.  14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified B3...PKZO-U, B3...-PKZ4 HPL07028EN

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Actuating voltages 2010 CA08103002Z-EN www.eaton.com 7/29 Actuating voltages Actuating voltage Part no.Article no. PriceSee price list Std. pack Part no.Article no. PriceSee price list Std. pack Notes Shunt release, undervoltage release AC Standard voltage 24 V 50 Hz A-PKZ0(24V50HZ) 1) 073181 2 off U-PKZ0(24V50HZ) 1) 073129 2 off 110 V 50 Hz A-PKZ0(110V50HZ) 1) 073184 2 off U-PKZ0(110V50HZ) 1) 073132 2 off 220 V 50 Hz A-PKZ0(220V50HZ) 1) 073186 2 off U-PKZ0(220V50HZ) 1) 073134 2 off 230 V 50 Hz A-PKZ0(230V50HZ) 1) 073187 2 off U-PKZ0(230V50HZ) 1) 073135 2 off Only A(U)-PKZ0... with serial number 02 or higher can be fitted 240 V 50 Hz A-PKZ0(240V50HZ) 1) 073188 2 off U-PKZ0(240V50HZ) 1) 073136 2 off 380 V 50 Hz A-PKZ0(380V50HZ) 1) 073189 2 off U-PKZ0(380V50HZ) 1) 073137 2 off 400 V 50 Hz A-PKZ0(400V50HZ) 1) 073190 2 off U-PKZ0(400V50HZ) 1) 073138 2 off 415 V 50 Hz A-PKZ0(415V50HZ) 1) 073191 2 off U-PKZ0(415V50HZ) 1) 073139 2 off 120 V 60 Hz A-PKZ0(120V60HZ) 1) 073195 2 off U-PKZ0(120V60HZ) 1) 073143 2 off 240 V 60 Hz A-PKZ0(240V60HZ) 1) 073198 2 off U-PKZ0(240V60HZ) 1) 073146 2 off 440 V 60 Hz A-PKZ0(440V60HZ) 1) 082164 2 off U-PKZ0(440V60HZ) 1) 082161 2 off 480 V 60 Hz A-PKZ0(480V60HZ) 1) 073199 2 off U-PKZ0(480V60HZ) 1) 073147 2 off Non-standard voltages not covered by above standard voltages …V 50 Hz (24 - 500 V) A-PKZ0( V50HZ) 1) 982165 2 off U-PKZ0( V50HZ)982162 The part number for ordering consists of the basic part number and the actuating voltage.For non-standard voltages, specify the required actuating voltage within the indicated range (... - ... V).Minimum order quantity is 10 units …V 60 Hz (24 – 600 V) A-PKZ0( V60HZ) 1) 982166 2 off U-PKZ0( V60HZ)982163 DC Standard voltage 24 V DC A-PKZ0(24VDC) 1) 073200 2 off PKE can be fitted only with A(U)-PKZ0... with serial number 02 or higher. 110 V DC A-PKZ0(110VDC) 1) 073203 2 off Information relevant for export to North America 1) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified A-PKZO, U-PKZO HPL07029EN

7/30 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE 2010 CA08103002Zen-US www.eaton.com Engineering Protection of PVC-insulated cables against thermal overload on short-circuitsThe table specifies which minimum conductor cross-sections are protected by motor-protective circuit-breaker PKZ(M) up to their rated conditional short-circuit current I q . 1- and 2-pole-connected PKZM0, PKZM4 and PKZ2 with AC and DC 1 3 5 2 4 6 I  I  I  1 3 5 2 4 6 I  I  I  2-pole-connected PKZM0(1) and PKZM4 with CL-PKZ0 1 3 5 1 3 5 2 L1 CL-PKZ0 PKZ0Z N 4 6 2 4 6 I I  I  I  I  I Min. cross-section protected380 – 415 V, 50 Hz, Cu mm 2 DevicePart no. Min. cross-section protected380 – 415 V, 50 Hz, Cu mm 2 DevicePart no. 4 2.5 1.5 1 0.75 PKZ2/ZM-0.6 PKZM0-0,16 ... ... PKZ2/ZM-2.4 PKZM0-6.3 PKZ2/ZM-4 PKZM0-10 PKZ2/ZM-6 PKZM0-12 PKZ2/ZM-10 PKZM0-16 PKZ2/ZM-16 PKZM0-20 PKZ2/ZM-25 PKZM0-25 PKZ2/ZM-32 PKZM0-32 PKZ2/ZM-40 PKZM4-16PKZM4-25PKZM4-32PKZM4-40PKZM4-50PKZM4-58PKZM4-63 PKZM0-...T tripping characteristics (not for PKM0-...), PKZM01 PKZM0...-T PKZM0-...,  PKZM01 min s ms 2 5 20 50 200 1 2 5 10 20 40 1 2 5 10 20 2 h 1.5 2 3 4 6 8 10 15 20 30 x I r 20 x I u 14 x I u   2 5 20 50 200 1 2 5 10 20 40 1 2 5 10 20 2 h 1.5 2 3 4 6 8 10 15 20 30 PKZM4-... min s ms x I r 14 x I u PKZ, PKZM

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE 2010 CA08103002Z-EN www.eaton.com 7/31 Tripping characteristic curves, wide-range circuit-breaker PKE Let-through characteristics, motor-protective circuit-breaker, transformer-protective circuit-breakers, circuit-breaker for starter combinations Motor-protective circuit-breaker let-through characteristics PKE... 21 2010 521 2010 521 500200 100 502010 52 100 30 40 50 70 20 15 10 7 5 4 3 2 1.5 1 1 t h min s ms x I r   12 x I r   14 x I u   CLASS5 CLASS20 CLASS10 CLASS15 [kA]   Î D 1  2 3 6 4 8 10 4.0 A 6.3 A 2.5 A 1.6 A 0.25 A 10 A/12 A 0.1 0.2 0.3 0.4 0.6 0.8 0.01 0.02 0.015 0.03 0.04 0.06 0.08 1 2 1.5 3 4 6 8 10 20 15 30 40 60 80100 U e  = 400 V 16 A 20 A 25 A 32 A 1 A 0.4 A 0.63 A PKZM0-.... PKZM01-.... PKM0-.... 2 ·  I cc I cc rms  [kA] U e  = 400 V PKZM01 PKZM0-.... PKM0-.... 10 4   1.5 2 3 64 8 10 5 4.0 A 6.3 A 2.5 A 1.6 A 1.0 A 10 A/12 A 10 3 2 1.5 3 4 6 8 10 2 2 1.5 3 4 6 8 1 2 1.5 3 4 6 8 10 20 15 30 40 60 80 100 16 A 20 A 25 A 32 A  [kA] [A 2  s]    i 2 dt 1 st  half-w ave I cc rms U e  = 400 V 10 10 100 63/58 A 50/40/32 A 25 A16 A PKZM4 1 1 100 [kA]   2 ·  I cc Î D I cc rms  [kA] 10 5 10 6 10 4 10 2 1 10 100 10 3 U e  = 400 V 63/58 A 50/40/32 A 25 A16 A PKZM4 [kA] [A 2  s]    i 2 dt 1 st  half-w ave 1 st  half-w ave I cc rms PKZM, PKE

7/32 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Switching capacity 2010 CA08103002Z-EN www.eaton.com Switching capacity Circuit-breaker switching capacity from serial no. 04 Rated uninterrupted current I u Rated conditional short-circuit current I q  IEC/EN 60947-4-1 Rated ultimate short-circuit breaking capacity I cu   IEC/EN 60947‐2 Rated breaking capacity I cs   } 230 V 400 V 440 V 500 V 690 V  I u I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs A kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) PKZM0, PKZM0...-T, PKM0 with type “1” and “2” coordination 0.16 – 1 150 150 150 N 150 150 150 N N N N 1.6 150 150 150 N 150 150 150 N N N N 2.5 150 150 150 N 150 150 150 N N N 5 5 5 50 4 150 150 150 N 150 150 150 N N N 3 3 3 50 6.3 150 150 150 N 150 150 150 N N 42 42 11 50 3 3 2 50 10 150 150 150 N 150 150 150 N 42 42 12 50 42 42 11 50 3 3 2 50 12 50 50 13 50 50 50 13 50 15 15 12 50 15 15 8 50 3 3 2 50 16 50 50 13 50 50 50 13 50 15 15 12 50 15 15 8 50 3 3 2 50 20 50 50 13 50 50 50 13 50 10 10 13 50 6 6 3 50 3 3 1 50 25 50 50 13 50 50 50 13 50 10 10 13 50 6 6 3 50 3 3 1 50 32 50 50 13 50 50 50 13 50 10 10 13 50 6 6 3 50 3 3 1 50 PKZM0 (PKZM0...-T, PKM0) + CL-PKZ0 0.16 – 1 N N N N 20 N 1.6 N N N N 20 N 2.5 N N N N 20 20 20 N 4 N N N N 20 20 20 N 6.3 N N N 50 N 20 20 20 N 10 N N N 20 N 20 20 20 N 12 N N N 20 N 5 5 2.5 N 16 N N N 20 N 5 5 2.5 N 20 N N N 10 10 10 N 5 5 2.5 N 25 N N N 10 10 10 N 5 5 2.5 N 32 N N N 10 10 10 N 5 5 2.5 N PKZM0 (PKZM0...-T, PKM0) + 2 CL-PKZ0 0.16 – 1 N N N N 20 N 1.6 N N N N 20 N 2.5 N N N N 40 40 20 N 4 N N N N 40 40 20 N 6.3 N N N 50 N 20 20 20 N 10 N N N 40 N 20 20 20 N 12 N N N 40 N 10 10 2.5 N 16 N N N 40 N 10 10 2.5 N 20 N N N 20 20 20 N 10 10 2.5 N 25 N N N 20 20 20 N 10 10 2.5 N 32 N N N 20 20 20 N 10 10 2.5 N Notes   No upstream protective device required, as it is the auto-protected range (100/150 kA) 1) Required back-up fuse if the short-circuit current exceeds the device's rated conditional short-circuit current (I cc    I q ). N Not necessary PKZM0

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Switching capacity 2010 CA08103002Z-EN www.eaton.com 7/33 Circuit-breaker switching capacity Rated uninterrupted current I u Rated conditional short-circuit current I q  IEC/EN 60947-4-1 Rated maximum short-circuit breaking capacity I cu   IEC/EN 60947‐2 Rated breaking capacity I cs   } 230 V 400 V 440 V 2) 500 V 2) 690 V 2)  I u I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs A kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) PKZM01 with type “1” and “2” coordination 0.16  –  1 50 50 50 50 50 50 50 50 50 50 50 50 1.6 50 50 50 50 50 50 50 50 50 50 50 50 2.5 50 50 50 50 50 50 50 50 50 50 50 50 4 50 50 50 50 50 50 50 50 50 50 50 50 6.3 50 50 50 50 50 50 50 50 50 50 50 50 10 50 50 50 50 50 50 50 50 42 42 10 50 12 50 50 10 50 50 50 10 50 15 15 10 50 16 50 50 10 50 50 50 10 50 15 15 10 50 20, 25 50 50 10 50 50 50 10 50 10 10 3 50 PKZM4 with type “1” and “2” coordination 16 150 150 25 N 150 150 25 N 45 45 25 100 15 15 100 8 8 2.5 100 25 150 150 25 N 150 150 25 N 45 45 25 100 15 15 100 8 8 2.5 100 32 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 100 40 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 100 50 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 100 58 50 50 25 160 50 50 25 160 45 45 25 160 15 15 160 5 5 2.5 160 63 50 50 25 160 50 50 25 160 45 45 25 160 15 15 160 5 5 2.5 160 PKE12... 2)  with type of coordination „1“ and  0.3 - 1.2 100 50 100 50 50 50 10 50 3 50 1 - 4 100 50 100 50 50 50 10 50 3 50 3 - 12 100 50 100 50 15 50 10 50 3 50 PKE32... 2)  with type of coordination „1“ and  3 - 12 100 50 100 50 15 50 6 50 3 50 8 - 32 100 50 100 50 25 50 6 50 3 50 Notes   No upstream protective device required,as it is the auto-protected range (150 kA) 1) Fuse (A gG/gL) for increasing the switching capacity of the motor-protective circuit-breaker to 100 kA 2) Please enquire for additional information regarding voltages 400 V and device combinations with CL-PKZ0. N Not necessary PKZM01, PKZM4, PKE Motor-protective circuit-breaker internal resistances  Impedance Heat  dissipation  (3 pole at  operating  temperature) Rated  uninterrupted  current I u Ω W A PKZM0-0,16 78 6 0.16 PKZM0-0.25 32 6 0.25 PKZM0-0.4 13 6 0.4 PKZM0-0.63 5 6 0.63 PKZM0-1 2 6 1 PKZM0-1.6 0.8 6 1.6 PKZM0-2.5 0.32 6 2.5 PKZM0-4 0.13 6 4 PKZM0-6.3 0.050 6 6.3 PKZM0-10 0.020 6 10 PKZM0-12 0.014 6 12 PKZM0-16 0.008 6 16 PKZM0-20 0.005 6 20 PKZM0-25 0.003 6 25 PKZM0-32 0.002 6 32 Impedance Heat  dissipation  (3 pole at  operating  temperature) Rated  uninterrupted  current I u Ω W A PKZM4-16 0.029 22 16 PKZM4-25 0.012 22 25 PKZM4-32 0.007 22 32 PKZM4-40 0.005 22 40 PKZM4-50 0.003 22 50 PKZM4-58 0.002 22 58 PKZM4-63 0.002 22 65 PKZ2-ZM-0.6 13 14 0.6 PKZ2-ZM-1 5 14 1 PKZ2-ZM-1.6 2 14 1.6 PKZ2-ZM-2.4 0.8 14 2.4 PKZ2-ZM-4 0.29 14 4 PKZ2-ZM-6 0.13 14 6 PKZ2-ZM-10 0.05 14 10 PKZ2-ZM-16 0.018 14 16 PKZ2-ZM-25 0.007 14 25 PKZ2-ZM-32 0.005 14 32 PKZ2-ZM-40 0.003 14 40

7/34 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breakers PKZM 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM Approvals for world markets Rating data for approved types 1) UL 508/CSA C 22.2 No. 14 Maximum motor rating Setting ranges Maximum protective device to UL/CSA Three-phase current Group protection 2) Overloadreleases Short-circuit-releases Up to max. short-circuit current Maximumfuse rating  Maximumcircuitbreaker  200 V 230 V 460 V  575 V 600 V with CL with CL with CL HP HP HP HP A A kA kA A A A A Motor-protective circuit-breakers PKZM01 “Manual Motor Starter with thermal and magnetic trip” PKZM01-0,16 3) 0.1 – 0.16 2.2 50 600 600 PKZM01-0.25 0.16 – 0.25 3.4 50 600 600 PKZM01-0.4 0.25 – 0.4 5.6 50 600 600 PKZM01-0,63 0.4 – 0.63 8.8 50 600 600 PKZM01-1 0.63 – 1 14 50 600 600 PKZM01-1,6 ¾ ¾ 1 – 1.6 22 50 600 600 PKZM01-2.5 ½ ½ 1 1½ 1.6 – 2,5 35 50 600 600 PKZM01-4 ¾ ¾ 2 3 2.5 – 4 56 50 600 600 PKZM01-6,3 1 1½ 3 5 4 – 6.3 88 50 600 600 PKZM01-10 3 3 7½ 10 6.3 – 11 140 22 50 150 600 125 600 PKZM01-12 3 3 7½ 10 9 – 12 168 18 50 150 600 125 600 PKZM01-16 3 5 10 10 10 – 16 224 10 50 150 600 125 600 PKZM01-20 5 - - 15 16 – 20 280 10 18 150 600 125 600 PKZM01-25 - 7½ 15 20 20 – 25 350 10 18 150 600 125 600 Motor-protective circuit-breakers PKZM01 “Manual Motor Starter with thermal and magnetic trip” PKZM0-0,16 3) 0.1 – 0.16 2.2 50 600 600 PKZM0-0.25 0.16 – 0.25 3.4 50 600 600 PKZM0-0.4 0.25 – 0.4 5.6 50 600 600 PKZM0-0.63 0.4 – 0.63 8.8 50 600 600 PKZM0-1 0.63 – 1 14 50 600 600 PKZM0-1.6 ¾ ¾ 1 – 1.6 22 50 600 600 PKZM0-2.5 ½ ½ 1 1½ 1.6 – 2,5 35 50 600 600 PKZM0-4 ¾ ¾ 2 3 2.5 – 4 56 50 600 600 PKZM0-6.3 1 1½ 3 5 4 – 6.3 88 50 600 600 PKZM0-10 3 3 7½ 10 6.3 – 11 140 22 50 150 600 125 600 PKZM0-12 3 3 7½ 10 9 – 12 168 18 50 150 600 125 600 PKZM0-16 3 5 10 10 10 – 16 224 10 50 150 600 125 600 PKZM0-20 5 - - 15 16 – 20 280 10 18 150 600 125 600 PKZM0-25 - 7½ 15 20 20 – 25 350 10 18 150 600 125 600 PKZM0-32 7½ 10 20 25 24 – 32 448 10 18 150 600 125 600 Motor-protective circuit-breakers PKZM4 PKZM4-16 3 5 10 15 10 – 16 224 50 600 600 PKZM4-25 7½ 7½ 20 25 16 – 25 350 50 600 600 PKZM4-32 10 10 25 30 25 – 34 448 50 600 600 PKZM4-40 10 15 30 40 32 – 42 560 50 600 600 PKZM4-50 10 15 30 40 40 – 52 700 10 600 600 PKZM4-58 15 15 40 50 50 – 56 812 10 600 600 PKZM4-63 15 15 40 50 52 – 58 882 10 600 600 Notes Service factor (SF) 1) Devices for world markets IEC ≙ UL/CSA Set value I r , on the current scale, depending on the  load factorSF = 1.15 → I r  = 1 x I n mot SF = 1 → I r  = 0.9 x I n mot 2) Caution: Changed requirements for group protection 3) Calculate motor output in this range according to rated operational current. Specified values as per NEC Table 430 – 150 PKZM01, PKZM0, PKZM4

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Type E starters 2010 CA08103002Z-EN www.eaton.com 7/35 Rating data for approved types 1) UL 508/CSA C 22.2 No. 14 For use with Pilot Duty General Use Accessories Standard auxiliary contacts NHI11-PKZ0 PKZM0(-T)PKZM4 A 600, Q 300 5 A – 600 V AC1 A – 250 V DC – NHI12-PKZ0NHI21-PKZ0NHI2-11S-PKZ0NHI-E-11-PKZ0 E150 0.5 A – 250 V AC – NHI-E-10-PKZ0 Early-make auxiliary contacts VHI20-PKZ0 PKZM0(-T) E150 0.5 A – 250 V AC – VHI20-PKZ01 PKZM01 Trip indicators AGM2-10-PKZ0 PKZM0(-T)PKZM4 A 600, Q 300 5 A – 600 V AC1 A – 250 V DC – AGM2-01-PKZ0 Shunt release A-PKZ0(...) PKZM0(-T)PKZM4 – – Actuating voltages and ordering information → Products for the German market U-PKZ0(...) Auxiliary contact for contact module HI11-S/EZ-PKZ0 PKZM0 A 600, Q 300 5 A – 600 V AC1 A – 250 V DC – Notes 1)  Devices for world markets IEC = UL/CSA Motor-protective circuit-breakers PKZM0(4) used as "Manual self-protected Motor Starters" – UL 508 Type EMaximum motor outputAC Setting ranges Interrupting Capacity =Short Circuit Current (SCCR) Components  200 V208 V 230 V240 V 460 V480 V 575 V600 V Overloadreleases Short-circuit releases 240 V 480Y/277 V 2) 600Y/347 V 2) MotorProtector Accessories [HP] [HP] [HP] [HP] [A] [A] [kA] [kA] [kA] Part no. Part no. 1) 0.1 – 0.16 2.2 65 65 50 PKZM0-0.16 BK25/3-PKZ0-E 0.16 – 0.25 3.4 65 65 50 PKZM0-0.25 BK25/3-PKZ0-E 0.25 – 0.4 5.6 65 65 50 PKZM0-0.4 BK25/3-PKZ0-E 0.4 – 0.63 8.8 65 65 50 PKZM0-0.63 BK25/3-PKZ0-E 0.63 – 1 14 65 65 50 PKZM0-1 BK25/3-PKZ0-E ¾ ¾ 1 – 1.6 22 65 65 50 PKZM0-1.6 BK25/3-PKZ0-E ½ ½ 1 1½ 1.6 – 2,5 35 65 65 50 PKZM0-2.5 BK25/3-PKZ0-E ¾ ¾ 2 3 2.5 – 4 56 65 65 50 PKZM0-4 BK25/3-PKZ0-E 1 1½ 3 5 4 – 6.3 88 65 65 50 PKZM0-6.3 BK25/3-PKZ0-E 3 3 7½ 10 6.3 – 11 140 65 65 50 PKZM0-10 BK25/3-PKZ0-E 3 3 7½ – 9 – 12 168 65 65 – PKZM0-12 BK25/3-PKZ0-E 3 5 10 – 10 – 16 224 42 42 – PKZM0-16 BK25/3-PKZ0-E 5 – – – 16 – 20 280 18 18 – PKZM0-20 BK25/3-PKZ0-E – 7½ 15 – 20 – 25 350 18 18 – PKZM0-25 BK25/3-PKZ0-E 7½ 10 20 – 24 – 32 448 18 18 – PKZM0-32 BK25/3-PKZ0-E 3 5 10 10 10 – 16  224 65 65 25 PKZM4-16 BK50/3-PKZ4-E 5 7½ 15 20 16 – 27 350 65 65 25 PKZM4-25 BK50/3-PKZ4-E 7½ 10 20 30 24 – 34 448 65 65 25 PKZM4-32 BK50/3-PKZ4-E 10 – 30 30 32 – 40 560 65 65 25 PKZM4-40 BK50/3-PKZ4-E – 15 30 – 40 – 52 700 65 65 – PKZM4-50 BK50/3-PKZ4-E – – 40 – 50 – 56 812 65 65 – PKZM4-58 BK50/3-PKZ4-E – – 40 – 52 – 58 882 65 – – PKZM4-63 BK50/3-PKZ4-E Notes 1)  Calculate motor power in this range according to the rated current. Stated values to NEC Table 430 -150 2)  Suitable for networks with grounded star-point PKZM

7/36 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Motor-protective circuit-breaker Technical data PKZM01… PKZM0-… 1) PKM0-… PKZM0-…-T PKZM4 PKE General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Storage °C -25…80 -25 …80 -25…80 -25…80 -25…70 -25…80 Open °C -25…55 -25…55 -25…55 -25…55 -25…55 -25…55 Encapsulated °C -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 Built-in position Direction of incoming supply Any Any Any Any Any Any Degree of protection Device IP20 IP20 IP20 IP20 IP20 IP20 Terminals IP00 IP00 IP00 IP00 IP00 IP00 Contact protection to EN 50274 Finger- and back-of-hand proof Finger- and back-of-hand proof Shock resistance, half-sinusoidal shock, 10 ms to IEC 60068-2-27 g 25 25 25 25 15 25 Installation altitude m max. 2000 max. 2000 max. 2000 max. 2000 max. 2000 max. 2000 Terminal capacity, screw terminals Solid mm 2 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 50)2 x (1 - 35) 1 x (1 - 6)2 x (1 - 6) Flexible with ferrule to DIN 46228 mm 2 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 35)2 x (1 - 35) 1 x (1 - 6)2 x (1 - 6) Solid or stranded AWG 18 - 10 18 - 10 18 - 10 18 - 10 14 - 2 18 - 10 Terminal capacity, spring-loaded terminals Solid mm 2 – 1 x (1…2.5)2 x (1…2.5) 1 x (1…2.5)2 x (1…2.5) – – 1 x (1…2.5)2 x (1…2.5) Flexible with ferrule to DIN 46228 mm 2 – 1 x (1…2.5)2 x (1…2.5) 1 x (1…2.5)2 x (1…2.5) – – 1 x (1…2.5)2 x (1…2.5) Solid or stranded AWG – 18…14 18…14 – – 18…14 Terminal screw tightening torque Main conductors Nm 1.7 1.7 1.7 1.7 3.3 1.7 Auxiliary conductors Nm 1 1 1 1 1 1 Main contacts Rated impulse withstand voltage  U imp V AC 6000 6000 6000 6000 6000 6000 Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3 Rated operational voltage U e V AC 690 690 690 690 690 690 Rated uninterrupted current = rated operational current I u  = I e A 16 or current setting of the overcurrent release 32 or current setting of the overcurrent release 32 or current setting of the overcurrent release 25 or current setting of the over-current release 65 Open63 enclosed 32 A or set current of the overcurrent release Rated frequency Hz 40 - 60 40 - 60 40 - 60 40 - 60 40 - 60 40 - 60 Heat dissipation (3 pole at operating temperature) W 6 6 6 6 22 6 Lifespan, mechanical Operations x 10 6 0.05 0.1 0.1 0.1 0.03 0.05 Lifespan, electrical (AC-3 at 400 V) Operations x 10 6 0.05 0.1 0.1 0.1 0.03 0.05 Maximum operating frequency Operations/h Ops/h 25 40 40 40 40 60 Short-circuit rating AC → Page 7/33 → Page 7/32 → Page 7/32 → Page 7/32 → Page 7/33 → Page 7/33 DC kA 60 60 (up to PKZM0-16)40 (PKZM0-20 to PKZM0-32) 60 (up to PKM0-16)40 (PKM0-20 to PKM0-32) 60 (up to PKZM0-16)40 (PKZM0-20 to PKZM0-32) 60 – Motor switching capacity AC-3 up to 690 V A 16 32 32 25 65 32 DC-5 (up to 250 V) A 16 (3 contacts in series) 25 (3 contacts in series) 25 (3 contacts in series) 25 (3 contacts in series) 63 (3 contacts in series) – Trip blocks Temperature compensation To IEC/EN 60947, VDE 0660 °C -5…40 -5…40 -5…40 -5…40 -5…40 -5…40 Operating range °C -25…55 -25…55 -25…55 -25…55 -25…55 -25…55 Temperature compensation residual error for T  40 °C %/K ≦ 0.25 ≦ 0.25 ≦ 0.25 ≦ 0.25 ≦ 0.25 Setting range of overload releases x I u 0.6 - 1 0.6 - 1 0.6 - 1 0.6 - 1 0.25 - 1 Short-circuit releases tolerance % ± 20 ± 20 ± 20 ± 20 ± 20 ± 20 Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 IEC/EN 60947-4-1, VDE 0660 Part 102 – IEC/EN 60947-1-1, VDE 0660 Part 102 IEC/EN 60947-4-1, VDE 0660 Part 102 Yes Notes 1)  Tested according to IEC/EN 60947-1 (isolating characteristics) and IEC/EN 60947-2 90° 90° 90° 90° 90° 90° 90° 90° 90° 90° 7/37 PKZM, PKE PKZM

7/36 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker Motor-protective circuit-breaker Technical data PKZM01… PKZM0-… 1) PKM0-… PKZM0-…-T PKZM4 PKE General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Storage °C -25…80 -25 …80 -25…80 -25…80 -25…70 -25…80 Open °C -25…55 -25…55 -25…55 -25…55 -25…55 -25…55 Encapsulated °C -25…40 -25…40 -25…40 -25…40 -25…40 -25…40 Built-in position Direction of incoming supply Any Any Any Any Any Any Degree of protection Device IP20 IP20 IP20 IP20 IP20 IP20 Terminals IP00 IP00 IP00 IP00 IP00 IP00 Contact protection to EN 50274 Finger- and back-of-hand proof Finger- and back-of-hand proof Shock resistance, half-sinusoidal shock, 10 ms to IEC 60068-2-27 g 25 25 25 25 15 25 Installation altitude m max. 2000 max. 2000 max. 2000 max. 2000 max. 2000 max. 2000 Terminal capacity, screw terminals Solid mm 2 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 50)2 x (1 - 35) 1 x (1 - 6)2 x (1 - 6) Flexible with ferrule to DIN 46228 mm 2 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 6)2 x (1 - 6) 1 x (1 - 35)2 x (1 - 35) 1 x (1 - 6)2 x (1 - 6) Solid or stranded AWG 18 - 10 18 - 10 18 - 10 18 - 10 14 - 2 18 - 10 Terminal capacity, spring-loaded terminals Solid mm 2 – 1 x (1…2.5)2 x (1…2.5) 1 x (1…2.5)2 x (1…2.5) – – 1 x (1…2.5)2 x (1…2.5) Flexible with ferrule to DIN 46228 mm 2 – 1 x (1…2.5)2 x (1…2.5) 1 x (1…2.5)2 x (1…2.5) – – 1 x (1…2.5)2 x (1…2.5) Solid or stranded AWG – 18…14 18…14 – – 18…14 Terminal screw tightening torque Main conductors Nm 1.7 1.7 1.7 1.7 3.3 1.7 Auxiliary conductors Nm 1 1 1 1 1 1 Main contacts Rated impulse withstand voltage  U imp V AC 6000 6000 6000 6000 6000 6000 Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3 Rated operational voltage U e V AC 690 690 690 690 690 690 Rated uninterrupted current = rated operational current I u  = I e A 16 or current setting of the overcurrent release 32 or current setting of the overcurrent release 32 or current setting of the overcurrent release 25 or current setting of the over-current release 65 Open63 enclosed 32 A or set current of the overcurrent release Rated frequency Hz 40 - 60 40 - 60 40 - 60 40 - 60 40 - 60 40 - 60 Heat dissipation (3 pole at operating temperature) W 6 6 6 6 22 6 Lifespan, mechanical Operations x 10 6 0.05 0.1 0.1 0.1 0.03 0.05 Lifespan, electrical (AC-3 at 400 V) Operations x 10 6 0.05 0.1 0.1 0.1 0.03 0.05 Maximum operating frequency Operations/h Ops/h 25 40 40 40 40 60 Short-circuit rating AC → Page 7/33 → Page 7/32 → Page 7/32 → Page 7/32 → Page 7/33 → Page 7/33 DC kA 60 60 (up to PKZM0-16)40 (PKZM0-20 to PKZM0-32) 60 (up to PKM0-16)40 (PKM0-20 to PKM0-32) 60 (up to PKZM0-16)40 (PKZM0-20 to PKZM0-32) 60 – Motor switching capacity AC-3 up to 690 V A 16 32 32 25 65 32 DC-5 (up to 250 V) A 16 (3 contacts in series) 25 (3 contacts in series) 25 (3 contacts in series) 25 (3 contacts in series) 63 (3 contacts in series) – Trip blocks Temperature compensation To IEC/EN 60947, VDE 0660 °C -5…40 -5…40 -5…40 -5…40 -5…40 -5…40 Operating range °C -25…55 -25…55 -25…55 -25…55 -25…55 -25…55 Temperature compensation residual error for T  40 °C %/K ≦ 0.25 ≦ 0.25 ≦ 0.25 ≦ 0.25 ≦ 0.25 Setting range of overload releases x I u 0.6 - 1 0.6 - 1 0.6 - 1 0.6 - 1 0.25 - 1 Short-circuit releases tolerance % ± 20 ± 20 ± 20 ± 20 ± 20 ± 20 Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 IEC/EN 60947-4-1, VDE 0660 Part 102 – IEC/EN 60947-1-1, VDE 0660 Part 102 IEC/EN 60947-4-1, VDE 0660 Part 102 Yes Notes 1)  Tested according to IEC/EN 60947-1 (isolating characteristics) and IEC/EN 60947-2 90° 90° 90° 90° 90° 90° 90° 90° 90° 90° 7/37 PKZM, PKE PKZM

7/38 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Auxiliary contacts 2010 CA08103002Z-EN www.eaton.com Auxiliary contacts NHI…PKZ0 NHI-E-…PKZ0 VHI…PKZ0 AGM Auxiliary contacts Rated impulse withstand voltage  U imp V AC 6000 4000 4000 6000 Overvoltage category/pollution degree III/3 III/3 III/3 III/3 Rated operating voltage   U e V AC 500 440 440 500 U e V DC 250 250 250 250 Safe isolation according to EN 61140 Between auxiliary contacts and main contacts V AC 690 690 690 690 Rated operational current AC-15 220 - 240 V I e A 3.5 1 1 3.5 380 - 415 V I e A 2 – – 2 440 - 500 V I e A 1 – – 1 DC-13 L/R ≦ 100 ms  24 V I e A 2 2 2 2  60 V I e A 1.5 – – 1.5  110 V I e A 1 – – 1  220 V I e A 0.25 – – 0.25 Durability Lifespan, mechanical Operations x 10 6 0.1 0.1 0.1  0.01 Lifespan, electrical Operations x 10 6  0.05 0.1 0.1  0.05 Control circuit reliability (at U e  = 24 V DC, U min  = 17 V,  I  min = 5.4 mA) Fault probability λ 10 -8   1 failure in 1 x 10 8  operations Interlocked opposing contacts Yes – – – Short-circuit rating without welding Fuseless FAZ-B4/1-HI – – FAZ-B4/1-HI Fuse A gG/gL 10 10 10 10 Terminal capacity Solid or flexible conductor with ferrule mm 2 0.75 - 2.5 0.75 - 1.5 0.75 - 1.5 0.75 - 2.5 Solid or stranded AWG 18 - 14 18 - 16 18 - 16 18 - 14 Undervoltage releaseU-PKZ... Shunt releaseA-PKZ... General Terminal capacity Solid or flexible conductor with ferrule mm 2 1 x (0.75 - 2.5)2 x (0.75 - 2.5) 1 x (0.75 - 2.5)2 x (0.75 - 2.5) Solid or stranded AWG 1 x (18 - 14)2 x (18 - 14) 1 x (18 - 14)2 x (18 - 14) Main contacts Rated operating voltage U e V AC 42 - 480 42 - 480 Rated operating voltage U e V DC 24 - 250 24 - 250 Pick-up-/drop-out voltage Pick-up voltage x U s 0.85 - 1.1 Drop-out voltage x U s 0.7 - 0.35 Operating range AC voltage x U s 0.7…1.1 DC voltage (intermittent operation 5 s) x U s 0.7…1.1 Power consumption AC voltage AC pick-up rating Pick-up VA 5 5 AC consumption when closed Holding VA 3 3 DC voltage DC pick-up rating Pick-up W – 3 DC consumption when closed Holding W – 3 NHI...PKZ, AGM, U-PKZ, A-PKZ

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Motor-protective circuit-breaker 2010 CA08103002Z-EN www.eaton.com 7/39 Motor-protective circuit-breaker Dimensions Motor-protective circuit-breakerPKZM01… Motor-protective circuit-breaker Motor-protective circuit-breakers with lockable rotary handles Transformer-protective circuit-breakersMotor-protective circuit-breaker with standard auxiliary contactsPKZM0-…(+NHI-E-…-PKZ0)PKZM0-…-T(+NHI-E-…-PKZ0)PKM0-…(+NHI-E-…-PKZ0) PKZM0-…+AK-PKZ0 Current limiters Motor-protective circuit-breakers with early-make auxiliary contacts CL-PKZ… PKZM0-…+VHI-…-PKZ0 ① Top-hat rail IEC/EN 60715 Standard auxiliary contacts Trip indicators Shunt releaseUndervoltage release NHI…-PKZ0 AGM2…-PKZ0 A-PKZ0…U-PKZ0… 5.5 45 45 93 44 74 85 NHI-E-..-PKZ0 NHI-E-..-PKZ0 70 55 45 25 93 50 76 68 45 4.5 45 AK-PKZ 0 AK-PKZ 0 93 50 88 94 45 70 7.5 49.5 44 7.5 4528 90 73 93 a VHI...-PKZ0 80 55 45 93 50 86 68 45 VHI...-PKZ0 9 26 68 45 90 36 9 26 68 45 90 36 18 49 68 36 45 90 PKZM01, PKZM0

7/40 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Busbar adapters 2010 CA08103002Z-EN www.eaton.com Busbar adapters BBA0-25 BBA2-63 BBA4/2TS-L BBA0-25/2TS BBA2-63/2TS BBA4L-63 BBA0/2TS-LBBA0-32BBA0-32/2TS-CBBA0C-16 BBA4-63 BBA2-80/2TS-S BBA2L-63 BBA0L-25 BBA0K-32 PKZM0-XC45L BBA0L-32 PKZM0-XC45L-2 200 45 35 63 10 40 60 60 a b ce f a b cd e f a c d a be f a BBA0-32/2TS-C b BBA0-25/2TSc BBA0C-16 d BBA0/2TS-L e BBA0-25 f BBA0-32 200 72 35 63 10 40 60 60 a  a BBA2-63/2TSb BBA2-63 a b 35 63 10 40 60 60 260 55 a  a b  a b a BBA4L-63 b BBA4/2TS-L 35 63 10 40 60 60 200 55 214 72 40 60 60 35 63 10 260 72 35 63 10 40 60 60 260 45 a b b a BBA0L-25b BBA0L-32 35 63 10 40 60 60 161 45 20 60 60 35 63 10 283 45 20 40 10 a b b a PKZM0-XC45Lb PKZM0-XC45L-2 BBA

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 2010 CA08103002Z-EN www.eaton.com 7/41 Accessories Insulated enclosures for surface mountingCI-PKZ0-M CI-PKZ10G...M CI-PKZ0-…M + SVB-PKZ0-CI Drilling dimensionsCI-PKZ0-…M CI-K2-PKZ0 CI-K2-PKZ0G(R)(V) CI-K2-PKZ0-G(R)(V) + SVB-PKZ0-CI Drilling dimensionsCI-K2-PKZ0… 80 158 90 100 70 80 158 97.5 125.5 98 30 44 55 SVB-PKZ0-CI 80 158 28 33 97.5 4.5 153 8 30 4.5 100 160 47.5 104 181 100 160 47.5 103 130 181 98 30 44 55 SVB-PKZ0-CI 97 181 28 33 114 171 M4 M4 30 160 PKZM01, PKZM0

7/42 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 2010 CA08103002Z-EN www.eaton.com Accessories Door coupling handlesPKZ0-X(R)H… Mounting depth: 100 to 240 mm from the top edge of the top-hat rail to the front edge of the cabinet door/coverDistance between switch axis and cover hinge: at least 100 mm ① At least 100 mm from cover hinge Insulated enclosures for flush mounting Mounting aperture E-PKZ0… E-PKZ0 E-PKZ0-G… E-PKZ0-G… + SVB-PKZ0-E Insulated enclosures for surface mounting Mounting plates CI23E… M3-CI23 54 20 64 64 48 48 7.5 a 69 85 129 96 80 124 55 R4 70–72 116 – 118 98 30 58 55 80 96 124 85 129 30 28 21 98 30 58 55 80 96 124 3 3 25 25 187.5 250 162 200 215 225 262 278 56 114 144 147 177 35 60 90 147 177 7 knockout 8 x PG 16 2 x PG 21/29 142.5 205 62.5 125 14 27 84.5 114.5 92 14 27 84.5 114.5 92 6 × PG 16 1 × PG 21/29 BBA

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 2010 CA08103002Z-EN www.eaton.com 7/43 Accessories Accessories Accessories Insulated enclosures for surface mounting CI-PKZ01 CI-PKZ01-PVT CI-PKZ01-SVB CI-PKZ01-G CI-PKZ01-PVS CI-PKZ01-SVB-V Insulated enclosures for flush mounting E-PKZ01 E-PKZ01-PVT E-PKZ01-G E-PKZ01-PVS E-PKZ01-SVBE-PKZ01-SVB-V 80 158 116.5 80 158 116.5 177.2 80 158 116.5 129.5 69 90.2 93 115.2 129 69 90.2 93 115.2 175.9 129 69 90.2 93 115.2128.2 129 PKZM01

7/44 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breaker Standard auxiliary contacts PKZM4-… NHI…-PKZ…NHI…-PKZ0 Motor-protective circuit-breakers with lockable cover Trip indicators PKZM4-… +AK-PKZ0 AGM2…-PKZ…AGM2…-PKZ0 PKE Motor-protective circuit-breakers PKE12 , PKE32 PKE65 30 NHI-E...  7.5  118  127  145  160  55  130  140  125  65  53  45  4  NHI-E...  9 26 68 45 90 36 30 7.5 118 127 145 171 55 130 140 125 65 45 4 AK-PKZ0 9 26 68 45 90 36 101 102.5 100.5 25 45 56.5 160 32.5 35 5.5 55 127 118 172 187 14.5 PKZM4, PKE

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 2010 CA08103002Z-EN www.eaton.com 7/45 Accessories Accessories Three-phase commoning links B3.0/4-PKZ4 B3.2/4-PKZ4 B3.0/3-PKZ4 B3.2/2-PKZ4 B3.0/2-PKZ4 B3.1/3-PKZ4 B3.1/4-PKZ4 B3.1/2-PKZ4 Three-phase commoning links Three-phase commoning links B3.0/4-PKZ0 B3.2/4-PKZ0 B3.0/2-PKZ0 B3.2/2-PKZ0 Three-phase commoning links Incoming terminals B3.1/5-PKZ0 B3.1/3-PKZ0 BK25/3-PKZ0 B3.1/4-PKZ0 B3.1/2-PKZ0 Overlapping mounting to extend the three-phase commoning link Motor plug DILM12-XMCP/T 14 205 36 33 33 14 260 36 14 151 36 33 14 115 36 33 14 98 36 33 33 14  170 36 33 14 232 36 33 14  117 36 180 (90) H-B3- PKZ 0 27 45 234 H-B3- PKZ0 27 63 H-B3- PKZ 0 27 261 (207, 153, 99) 54 BK25/3-PKZ0 F 41 73 7.5 31 48 F 56  B3...-PKZ0 45 62 94 27 85 PKZM0, PKZM4

7/46 Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4, PKE Accessories 2010 CA08103002Z-EN www.eaton.com Insulated enclosures for surface mounting CI-K4-PKZ4-G(R) CI-K4-PKZ4-G +SVB-PKZ4-CI Drilling dimensionsCI-K4-PKZ-G(R) 32 98 SVB-PKZ4-CI 72 3 160 240 134181197 160 186 28 30 240 240 193 142 o 5.6 72 PKZM4

2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breaker 7/47 Motor-protective circuit-breaker System overview 1 4 5 6 7 8 2 3 10 10 9 Basic devices Motor-protective circuit-breakers 1 → Page 7/48 Circuit-breakers 1 → Page 7/48 Add-on functions Contact modules 6 → Page 7/64 High-capacity contact modules 7 → Page 7/64 Auxiliary contacts 10 → Page 7/58 Current limiters 8 → Page 7/58 Shunt release 4 → Page 7/60 Remote operators 5 → Page 7/62 Mounting accessories Mounting/wiring 2 → Page 7/69 Door coupling handles IP65 9 → Page 7/57 Insulated enclosures 3 → Page 7/56 PKZ2

7/48 Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breakers, circuit-breaker 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breakers, circuit-breaker Motor-protective circuit-breakers, circuit-breaker Ordering Max. motor rating Rated uninterrupted current Setting range Part no.Article no. Price See price list Std. pack Notes Notes Notes AC-3  I u Overload releases Short-circuit releases 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V  690 V A I r I rm P P P P P A A kW kW kW kW kW Motor-protective circuit-breakers,  type of coordination “1” and “2” 0.09 0.12 0.18 0.25 0.25 0.6 0.4…0.6 5 …8 PKZ2/ZM-0.6021859 1 off Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Adjustable overload releaseI r  = 0.6 - 1.0 x I u Adjustable short-circuit release I rm  = 8.5 - 14 x I u  factory-set to 12 x I u PTB 02 ATEX 3152Observe manual. Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height 0.12 0.25 0.25 0.37 0.55 1 0.6…1 8 …14 PKZ2/ZM-1026605 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14 …22 PKZ2/ZM-1.6028978 0.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20 …35 PKZ2/ZM-2.4031351 0.75 1.5 1.5 2.2 3 4 2.4…4 35 …55 PKZ2/ZM-4033724 1.1 2.2 3 3 4 6 4…6 50 …80 PKZ2/ZM-6036097 2.2 4 4 5.5 7.5 10 6…10 80 …140 PKZ2/ZM-10038470 4 7.5 9 9 12.5 16 10…16 130 …220 PKZ2/ZM-16040843 5.5 12.5 12.5 15 22 25 16…25 200 …350 PKZ2/ZM-25043216 7.5 15 17.5 22 22 32 24…32 275  …425 PKZ2/ZM-32045589 11 20 22 24 30 40 32…40 350 …500 PKZ2/ZM-40047962 Circuit-breakers For line and cable protection – – – – – 10 6…10 50  …80 PKZ2/ZM-10-8050335 1 off Adjustable overload release I r  = 0.6 - 1.0 x I u Adjustable short-circuit releaseI rm  = 5.0 - 8.5 x I u  factory-set to 5 x I u Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height – – – – – 16 10…16 80  …140 PKZ2/ZM-16-8052708 – – – – – 25 16…25 130  …210 PKZ2/ZM-25-8055081 – – – – – 32 24…32 160  …280 PKZ2/ZM-32-8057454 – – – – – 40 32…40 200  …350 PKZ2/ZM-40-8059827 Notes Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Suitable for Branch circuit: as manual controller suitable for group installations See also → Page 7/75 Accessories Page 3 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/58 6 Shunt releases, undervoltage releases → 7/60 7 Remote operators → 7/62 8 Contact module, high-capacity contact modules, current limiters → 7/64 9 Clip plate → 7/69 Additional accessories → 7/56 Rated ultimate short-circuit breaking capacity → 7/78 Manual → 7/69 5 3 9 7 6 8 I  I  7/49 PKZ2 HPL07048EN PKZ2 HPL07049EN

7/48 Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breakers, circuit-breaker 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breakers, circuit-breaker Motor-protective circuit-breakers, circuit-breaker Ordering Max. motor rating Rated uninterrupted current Setting range Part no.Article no. Price See price list Std. pack Notes Notes Notes AC-3  I u Overload releases Short-circuit releases 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V  690 V A I r I rm P P P P P A A kW kW kW kW kW Motor-protective circuit-breakers,  type of coordination “1” and “2” 0.09 0.12 0.18 0.25 0.25 0.6 0.4…0.6 5 …8 PKZ2/ZM-0.6021859 1 off Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Adjustable overload releaseI r  = 0.6 - 1.0 x I u Adjustable short-circuit release I rm  = 8.5 - 14 x I u  factory-set to 12 x I u PTB 02 ATEX 3152Observe manual. Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height 0.12 0.25 0.25 0.37 0.55 1 0.6…1 8 …14 PKZ2/ZM-1026605 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14 …22 PKZ2/ZM-1.6028978 0.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20 …35 PKZ2/ZM-2.4031351 0.75 1.5 1.5 2.2 3 4 2.4…4 35 …55 PKZ2/ZM-4033724 1.1 2.2 3 3 4 6 4…6 50 …80 PKZ2/ZM-6036097 2.2 4 4 5.5 7.5 10 6…10 80 …140 PKZ2/ZM-10038470 4 7.5 9 9 12.5 16 10…16 130 …220 PKZ2/ZM-16040843 5.5 12.5 12.5 15 22 25 16…25 200 …350 PKZ2/ZM-25043216 7.5 15 17.5 22 22 32 24…32 275  …425 PKZ2/ZM-32045589 11 20 22 24 30 40 32…40 350 …500 PKZ2/ZM-40047962 Circuit-breakers For line and cable protection – – – – – 10 6…10 50  …80 PKZ2/ZM-10-8050335 1 off Adjustable overload release I r  = 0.6 - 1.0 x I u Adjustable short-circuit releaseI rm  = 5.0 - 8.5 x I u  factory-set to 5 x I u Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height – – – – – 16 10…16 80  …140 PKZ2/ZM-16-8052708 – – – – – 25 16…25 130  …210 PKZ2/ZM-25-8055081 – – – – – 32 24…32 160  …280 PKZ2/ZM-32-8057454 – – – – – 40 32…40 200  …350 PKZ2/ZM-40-8059827 Notes Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Suitable for Branch circuit: as manual controller suitable for group installations See also → Page 7/75 Accessories Page 3 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/58 6 Shunt releases, undervoltage releases → 7/60 7 Remote operators → 7/62 8 Contact module, high-capacity contact modules, current limiters → 7/64 9 Clip plate → 7/69 Additional accessories → 7/56 Rated ultimate short-circuit breaking capacity → 7/78 Manual → 7/69 5 3 9 7 6 8 I  I  7/49 PKZ2 HPL07048EN PKZ2 HPL07049EN

7/50 Motor-protective circuit-breakers PKZ2 Compact starters, high-capacity compact starters 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Compact starters, high-capacity compact starters Compact starters, high-capacity compact starters Max. motor rating Rated uninterrupted current Setting range Part no.Article no. Price See price list Std. pack Notes Notes AC-3  I u Overload releases Short-circuit releases 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V 660 V 690 V A I r I rm P P P P P A A kW kW kW kW kW Compact starters, type “1” coordination 0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-1/SE1A/11(230V50HZ,240V60HZ)063364 1 off 1 NC and 1 N/O auxiliary contact built into the contact module. The compact starters consist of a motor-protective circuit-breaker, which features a plug-in trip block and an attached contact module with the same matching profile. The devices are prefitted to a clip plate and can be snap-fitted, as a unit, centrally onto one or two top-hat rails to IEC/EN 60715 conform top-hat rails.They conform with IEC/EN 60947-4-1, VDE 0660 Part 102.I q  = Rated conditional short-circuit current 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1.6/SE1A/11(230V50HZ,240V60HZ)063372 0.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2.4/SE1A/11(230V50HZ,240V60HZ)063382 0.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4/SE1A/11(230V50HZ,240V60HZ)063392 1.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-6/SE1A/11(230V50HZ,240V60HZ)063402 2.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-10/SE1A/11(230V50HZ,240V60HZ)063412 4 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-16/SE1A/11(230V50HZ,240V60HZ)063422 5.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-25/SE1A/11(230V50HZ,240V60HZ)063432 7.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-32/SE1A/11(230V50HZ,240V60HZ)063442 11 18.5 22 24 30 36 32…40 350…500 PKZ2/ZM-40/SE1A/11(230V50HZ,240V60HZ)063452 High-capacity compact starters, type “2” coordination 0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-1/S(230V50HZ,240V60HZ)063472 1 off Rated short-circuit currentI q  = 100 kA/400 V High-capacity contact module has built-in auxiliary contacts: 1 M/1 B 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1.6/S(230V50HZ,240V60HZ)063482 0.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2.4/S(230V50HZ,240V60HZ)063492 0.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4/S(230V50HZ,240V60HZ)063502 1.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-6/S(230V50HZ,240V60HZ)063512 2.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-10/S(230V50HZ,240V60HZ)063522 4 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-16/S(230V50HZ,240V60HZ)063532 5.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-25/S(230V50HZ,240V60HZ)063542 7.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-32/S(230V50HZ,240V60HZ)063552 11 18.5 22 24 30 36 32…40 350…500 PKZ2/ZM-40/S(230V50HZ,240V60HZ)063562 Notes Information relevant for export to North America Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 012528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Suitable for Branch circuit: as manual controller with contactor, suitable for group installations See also → Page 7/75 L A1 13 21 14 22 A2 T Ι   Accessories Page 3 Standard auxiliary contacts → 7/58 4 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/58 6 Shunt release, undervoltage release → 7/60 7 Remote operators → 7/62 9 Clip plate → 7/69 Additional accessories → 7/56 Further actuating voltages → 7/70 Manual → 7/69 5 3 4 7 6 9 Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102Supplied ready mounted on clip plate C-PKZ2, can be snap-fitted to one or two IEC/EN 60715 top-hat rails, height 15 mm Overload releases adjustable I r  = 0.6 - 1.0 x I u Adjustable short-circuit release I rm  = 8.5 - 14 x I u  factory-set  to 12 x I u PTB 02 ATEX 3152Observe manual. L A1 13 21 14 22 A2 T I  I  7/51 HPL07050EN PKZ2/ZM HPL07051EN

7/50 Motor-protective circuit-breakers PKZ2 Compact starters, high-capacity compact starters 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Compact starters, high-capacity compact starters Compact starters, high-capacity compact starters Max. motor rating Rated uninterrupted current Setting range Part no.Article no. Price See price list Std. pack Notes Notes AC-3  I u Overload releases Short-circuit releases 220 V 230 V 240 V 380 V 400 V 415 V  440 V  500 V 660 V 690 V A I r I rm P P P P P A A kW kW kW kW kW Compact starters, type “1” coordination 0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-1/SE1A/11(230V50HZ,240V60HZ)063364 1 off 1 NC and 1 N/O auxiliary contact built into the contact module. The compact starters consist of a motor-protective circuit-breaker, which features a plug-in trip block and an attached contact module with the same matching profile. The devices are prefitted to a clip plate and can be snap-fitted, as a unit, centrally onto one or two top-hat rails to IEC/EN 60715 conform top-hat rails.They conform with IEC/EN 60947-4-1, VDE 0660 Part 102.I q  = Rated conditional short-circuit current 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1.6/SE1A/11(230V50HZ,240V60HZ)063372 0.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2.4/SE1A/11(230V50HZ,240V60HZ)063382 0.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4/SE1A/11(230V50HZ,240V60HZ)063392 1.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-6/SE1A/11(230V50HZ,240V60HZ)063402 2.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-10/SE1A/11(230V50HZ,240V60HZ)063412 4 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-16/SE1A/11(230V50HZ,240V60HZ)063422 5.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-25/SE1A/11(230V50HZ,240V60HZ)063432 7.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-32/SE1A/11(230V50HZ,240V60HZ)063442 11 18.5 22 24 30 36 32…40 350…500 PKZ2/ZM-40/SE1A/11(230V50HZ,240V60HZ)063452 High-capacity compact starters, type “2” coordination 0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-1/S(230V50HZ,240V60HZ)063472 1 off Rated short-circuit currentI q  = 100 kA/400 V High-capacity contact module has built-in auxiliary contacts: 1 M/1 B 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1.6/S(230V50HZ,240V60HZ)063482 0.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2.4/S(230V50HZ,240V60HZ)063492 0.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4/S(230V50HZ,240V60HZ)063502 1.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-6/S(230V50HZ,240V60HZ)063512 2.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-10/S(230V50HZ,240V60HZ)063522 4 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-16/S(230V50HZ,240V60HZ)063532 5.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-25/S(230V50HZ,240V60HZ)063542 7.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-32/S(230V50HZ,240V60HZ)063552 11 18.5 22 24 30 36 32…40 350…500 PKZ2/ZM-40/S(230V50HZ,240V60HZ)063562 Notes Information relevant for export to North America Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 012528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Suitable for Branch circuit: as manual controller with contactor, suitable for group installations See also → Page 7/75 L A1 13 21 14 22 A2 T Ι   Accessories Page 3 Standard auxiliary contacts → 7/58 4 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/58 6 Shunt release, undervoltage release → 7/60 7 Remote operators → 7/62 9 Clip plate → 7/69 Additional accessories → 7/56 Further actuating voltages → 7/70 Manual → 7/69 5 3 4 7 6 9 Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102Supplied ready mounted on clip plate C-PKZ2, can be snap-fitted to one or two IEC/EN 60715 top-hat rails, height 15 mm Overload releases adjustable I r  = 0.6 - 1.0 x I u Adjustable short-circuit release I rm  = 8.5 - 14 x I u  factory-set  to 12 x I u PTB 02 ATEX 3152Observe manual. L A1 13 21 14 22 A2 T I  I  7/51 HPL07050EN PKZ2/ZM HPL07051EN

7/52 Motor-protective circuit-breakers PKZ2 Motor and system protection modules 2010 CA08103002Z-EN www.eaton.com Motor and system protection modules Rated uninterrupted current Part no.Article no. Price See price list Std. pack Information relevant for export to North America  I u A Basic device, 3 poles, motor and system protection – 40 PKZ2026606 1 off Basic device,3 pole, motor protection Basic device PKZ2 with high-capacity contact module fitted S-PKZ2 (1 NC, 1 N/O) supplied on C-PKZ2 clip plate.  Cannot be combined with Z...-0.6-PKZ2.. 40 PKZ2/S(230V50HZ,240V60HZ)063572 1 off Basic device PKZ2 with SE1A/11-PKZ2 contact module fitted (1 NC, 1 N/O) supplied on C-PKZ2 clip plate. Cannot be combined with Z...-0.6-PKZ2. 40 PKZ2/SE1A/11(230V50HZ,240V60HZ)082142 1 off Basic device, 4 poles, system protection - 40 PKZ24004521 1 off Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Circuit for  ZM…PKZ2(4) M…PKZ2(4) ZMR…PKZ2 Adjustable:H ≙ manual position orA ≙ automatic positionFor EEx e applications the 95/96 break contact must always be used to de-energize the (high-capacity) contact module or contactor.Motor-protective trip blocks ZMR-...-PKZ2 cannot be combined with U/A voltage releases and RE/RS remote operators. Further actuating voltages → Page 7/70 Manual → Page 7/69 I  I  95 96 97 98 H A I  PKZ2, PKZ2/S... HPL07052EN

Motor-protective circuit-breakers PKZ2 Motor and system protection modules 2010 CA08103002Z-EN www.eaton.com 7/53 Maximum motor rating Rated short-circuit breaking capacity I cn Part no.Article no. Price See price list Std. pack Information relevant for export to North America AC  240 V AC 480 V AC 600 V AC  200 V  230 V  460 V  575 V HP HP HP HP kA kA kA Basic device In connection with motor-protective trip blocks ZM-...PKZ2 → Page 7/70The values given are maximum values, depending on the trip block DOL starter 10 15 30 25 100 65 42 PKZ2/S-SP(110V50HZ,120V60HZ)050940 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E123500 UL CCN NKJH NA Certification UL Listed, CSA certified Suitable for Branch circuit: as Type E self-protected combination motor controller See also TB_PKZ2_PRO_Netze_NA Reversing starters 10 15 30 25 100 65 42 PKZ2-SP-FVR( V HZ)925109 1 off Product StandardsUL 508; CSA-C22.2 No. 14; IEC60947- 4-1; CE marking UL File No. E123500 UL CCN NKJH CSA File No. 12528 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified Specially designed for NAYesSuitable for Branch circuit: as Reversing Type E self-protected combination motor controller See also TB_PKZ2_PRO_Netze_NA Notes Specify actuating voltage in the range 24 – 600 V 50 or 60 Hz. Terminal capacities, high-capacity compact starters PKZ2/ZM…/SMain terminalsCables Cu 75 °C, min. AWG 14, max. AWG 6Torque 1.8 NmControl circuit terminalsCables min. AWG 20, max. AWG 16 (0.5–1 mm 2 ) With insulated/uninsulated blade terminal, nominal size 2.8 Application: Mains supply up to 27 A 600 Y/347 V AC480 Y/277 V AC 27 – 42 A 480 Y/277 V AC Service factor (SF) Set value Ir on the current scale, depending on the load factorSF = 1.15 → I r  = 1 x I n mot SF = 1 → I r  = 0.9 x I n mot PKZ2/S... HPL07053EN

7/54 Motor-protective circuit-breakers PKZ2 Motor protection modules 2010 CA08103002Z-EN www.eaton.com Motor protection modules Max. motor rating Rated uninter-rupted current Setting range Part no.Article no. Price See price list Std. pack Notes AC-3 Overload releases Short-circuit releases 220 V230 V240 V 380 V400 V415 V  440 V  500 V 660 V690 V P P P P P   I u I r I rm kW kW kW kW kW A A A Motor-protective trip blocks, 3 pole With overload release 0.09 0.12 0.18 0.25 0.25 0.6 0.4…0.6 5…8 ZM-1,6-PKZ2024232 1 off Phase failure sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102 Adjustable overload releaseI r  = 0.6 - 1.0 x I u Adjustable short-circuit releaseI rm  = 8.5 - 14 x I u Factory-set to 12 x I u PTB 02 ATEX 3152Observe manual. 0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 ZM-1-PKZ2028979 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 ZM-1,6-PKZ2031352 0.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 ZM-2.4-PKZ2033725 0.75 1.5 1.5 2.2 3 4 2.4…4 35…55 ZM-4-PKZ2036098 1.1 2.2 3 3 4 6 4…6 50…80 ZM-6-PKZ2038471 2.2 4 4 5.5 7.5 10 6…10 80…140 ZM-10-PKZ2040844 4 7.5 9 9 12.5 16 10…16 130…220 ZM-16-PKZ2043217 5.5 12.5 12.5 15 22 25 16…25 200…350 ZM-25-PKZ2045590 7.5 15 17.5 22 22 32 24…32 275…425 ZM-32-PKZ2047963 11 20 22 24 30 40 32…40 350…500 ZM-40-PKZ2050336 With overload/relay function, with manual/automatic position 0.09 0.12 0.18 0.25 0.25 0.6 0.4…0.6 5…8 ZMR-0,6-PKZ2033943 1 off Phase failure sensitivity, adjustability and    as ZM blocks. When using motor-protective trip blocks with overload relay function, an overload does not cause the motor-protective circuit-breakerto trip.  The overload indication is provided by means of two auxiliary contacts. 0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 ZMR-1-PKZ2033950 0.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 ZMR-1,6-PKZ2033952 0.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 ZMR-2.4-PKZ2033955 0.75 1.5 1.5 2.2 3 4 2.4…4 35…55 ZMR-4-PKZ2033957 1.1 2.2 3 3 4 6 4…6 50…80 ZMR-6-PKZ2033966 2.2 4 4 5.5 7.5 10 6…10 80…140 ZMR-10-PKZ2033967 4 7.5 9 9 12.5 16 10…16 130…220 ZMR-16-PKZ2033968 5.5 12.5 12.5 15 22 25 16…25 200…350 ZMR-25-PKZ2033969 7.5 15 17.5 22 22 32 24…32 275…425 ZMR-32-PKZ2033973 11 20 22 24 30 40 32…40 350…500 ZMR-40-PKZ2033975 Notes Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified See also HPL2007/2008_17/36 ZM...PKZ2, ZM(R)...-PKZ2, M-PKZ2 HPL07054EN

Motor-protective circuit-breakers PKZ2 Motor and system protection modules 2010 CA08103002Z-EN www.eaton.com 7/55 Motor and system protection modules Without overload release – – – – – 0.6 5…8 M-0,6-PKZ2004537 1 off Adjustable short-circuit releaseI rm  = 8.5 - 14 x I u Factory set to 12  x I u When using the M-…-PKZ2 as a short-circuit protective device for motors with heavy starting duty, rated operational current Ie must be overspecified with the following factors when designing the switchgear: – – – – – 1 8…14 M-1-PKZ2004538 – – – – – 1.6 14…22 M-1,6-PKZ2004539 – – – – – 2.4 20…35 M-2.4-PKZ2004540 – – – – – 4 35…55 M-4-PKZ2004541 – – – – – 6 50…80 M-6-PKZ2004542 – – – – – 10 80…140 M-10-PKZ2004543 – – – – – 16 130…220 M-16-PKZ2004544 – – – – – 25 200…350 M-25-PKZ2004545 – – – – – 32 275…425 M-32-PKZ2004546 – – – – – 40 350…500 M-40-PKZ2004547 Rated uninterrupted current Setting range Part no.Article no. Price See price list Std. pack Notes  I u Overload releases Short-circuit releases A I r I rm A A Trip blocks for system protection 3 pole With overload release 10 6…10 50…80 ZM-10-8-PKZ2062201 1 off Adjustable overload releasel r  = 0.6 - 1.0 x I u Adjustable short-circuit releaseI rm  = 5 - 8.5 x I u  factory-set to 5 x I u 16 10…16 80…140 ZM-16-8-PKZ2059828 25 16…25 130…210 ZM-25-8-PKZ2057455 32 24…32 160…280 ZM-32-8-PKZ2055082 40 32…40 200…350 ZM-40-8-PKZ2052709 4 pole With overload releases in all 4 poles 10 6…10 50…80 ZM-10-8-PKZ24004526 1 off Adjustable overload releaseI r  = 0.6 - 1.0 x I u Adjustable short-circuit releaseI rm  = 5 - 8.5 x I u  factory-set to 5 x I u Circuit-breakers PKZ24/ZM-…-8 protect 4 poles 16 10…16 80…140 ZM-16-8-PKZ24004525 25 16…25 130…210 ZM-25-8-PKZ24004524 32 24…32 160…280 ZM-32-8-PKZ24004523 40 32…40 200…350 ZM-40-8-PKZ24004522 Max. motor rating Rated uninter-rupted current Setting range Part no.Article no. Price See price list Std. pack Notes AC-3 Overload releases Short-circuit releases 220 V230 V240 V 380 V400 V415 V  440 V  500 V 660 V690 V P P P P P   I u I r I rm kW kW kW kW kW A A A CLASS Factor5 1.0 10 1.0 15 1.22 20 1.41 25 1.58 30 1.73 35 1.89 40 2.0 ZM...PKZ2, ZM(R)...-PKZ2, M-PKZ2 HPL07055EN

7/56 Motor-protective circuit-breakers PKZ2 Insulated enclosures 2010 CA08103002Z-EN www.eaton.com Insulated enclosures For use with Part no.Article no. Price See price list Std. pack Notes Insulated enclosures for surface mounting For motor-protective circuit-breakers, 3 or 4 pole circuit-breaker Degree of protection IP40, cover with aperture dimensioned to accommodate front of breaker incl. blanking strip PKZ2/ZM-… +NHI + AGM + U or A and RE or RS PKZ24/ZM-… + NHI + AGM + U or A CI19EA-PKZ2026234 1 off Integrated IEC/EN 60715 top-hat rail, separate terminals for PE(N) and N connection Incl. cable entries 2 x PG 16/21/29 Indicator light L-PKZ0 be fitted Degree of protection IP54 prepared for mounting of a PKZ2-X(R)H-CI rotary handle PKZ2/ZM-… + NHI + AGM + U or A + (R)H CI19EB-PKZ2028607 1 off Degree of protection IP54 prepared for mounting of a PKZ2-X(R)H-CI rotary handle PKZ24/ZM-… + NHI + AGM + U or A + (R)H CI19ED-PKZ24005145 1 off For 3 pole compact starter, high-capacity compact starter, combination circuit-breakers Degree of protection IP40, cover with aperture dimensioned to accommodate front of breaker incl. blanking strip PKZ2/ZM-…/S(E1A) + NHI + AGM + RE or RS and U or A CI23EA-PKZ2087936 1 off Mounting plate L3/5-CI23 integrated Prepared for a compact starter or a High-capacity compact starters PKZ2/ZM-.../S without fitted clip plate Degree of protection IP54 prepared for mounting of a PKZ2-X(R)H-CI rotary handle PKZ2/ZM-…/S + NHI + AGM + U or A + (R)H CI23EB-PKZ2090309 1 off Insulated enclosure for motor-protective circuit breakers PKZ2/ZM Degree of protection NEMA 12 Prepared for mounting a door coupling handle PKZ2-X(R)H – CI19EE-PKZ2-NA 1) 003183 1 off Integrated IEC/EN 60715 top-hat rail, for connecting installation pipes and end-to-end earthingNot for use with PKZ2/ZM...S(-SP) With mounting plate without apertures – CI19E-125/M-NA 2) 033451 1 off For connection of conduit and continuous earthingNot for use with PKZ2/ZM...S(-SP) Insulated enclosures for flush mounting For motor-protective circuit-breakers, 3 or 4 pole circuit-breaker IP41 degree of protection, grey front plate with retaining frame, integral PE(N) terminal PKZ2/ZM-…+ NHI + AGMPKZ2/ZM-…+U or A (undervoltage or shunt release)PKZ24/ZM-… E-PKZ2003218 1 off For side-wall or door mountingVertical mounting positionIndicator light L-PKZ0 can befitted For degree of protection IP54,  door coupling rotary handle PKZ2-X(R)H always required in addition PKZ2/ZM-…+ NHI + AGMPKZ2/ZM-…+U or A (undervoltage or shunt release)PKZ24/ZM-… E54-PKZ2033939 1 off For side-wall or door mountingVertical mounting positionIndicator light L-PKZ0 can befitted Information relevant for export to North America 1) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Specially designed for NA✓Degree of Protection IEC: -, UL/CSA Type: 12 See also HPL2007/2008_17/36 2) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. On request UL CCN On request CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Specially designed for NA✓Degree of Protection IEC: -, UL/CSA Type: 12 See also HPL2007/2008_17/36 CI...-PKZ, E...-PKZ HPL07056EN

Motor-protective circuit-breakers PKZ2 Insulated enclosure 2010 CA08103002Z-EN www.eaton.com 7/57 Insulated enclosure Color Part no.Article no. Price See price list Std. pack Notes Information relevant for export to North America Neutral terminal For connecting a 5th conductor in enclosure E-PKZ2, E54-PKZ2  – – N-PKZ2003219 1 off – Door coupling handles Degree of protection IP65 / UL/CSA Type 4X/Type 12 For use as main switch to EN 60204 Black PKZ2-XH106127 1 off Lockable in 0-positionSuitable for 3 padlocks with 4 – 8 mm hasp thickness Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified For use in MCC distribution boards with PKZ2 turned through 90°. For use as main switch according to EN 60204 Black PKZ2-XH-MCC106130 1 off For use as a main switch with  emergency switching off function to EN 60204 Red-yellow PKZ2-XRH106128 1 off Plug-in extension shaft for door coupling handle Can be cut to any required length for mounting depths from 171 – 300 mm – – PKZ2-XAH106129 1 off – Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Rotary handle for insulated enclosures CI19(23)...-PKZ2 – Black PKZ2-XH-CI138580 1 off – – Red-yellow PKZ2-XRH-CI138581 1 off – HPL07057EN

7/58 Motor-protective circuit-breakers PKZ2 Accessories 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Accessories Accessories Contact configuration Contact sequence Circuit diagrams Part no.Article no. Price See price list Std. pack Notes Notes N/O = normally open contact NC = normally closed contact Standard auxiliary contacts 1 For motor-protective circuit-breaker, circuit-breakers and (high-capacity) compact starters 1 N/O 1 NC NHI11-PKZ2090677 1 off Can be fitted to circuit-breakers and (high-capacity) compact starters. Can be combined with trip-indicating auxiliary contacts AGM 2 N/O 2 NC NHI22-PKZ2097796 1 off For compact starters 1 N/O 1 NC NHI11S-PKZ2007623 1 off Can be fitted to starter combinations Can be combined with AGM trip-indicating auxiliary contacts 2 N/O 2 NC NHI22S-PKZ2000504 1 off 2 x 1 N/O 2 x 1 NC NHI2-11S-PKZ2009996 1 off Trip indicating auxiliary contacts with short-circuit indicator 1 For motor-protective circuit-breaker, circuit-breakers and (high-capacity) compact starters 2 x 1 N/O 2 x 1 NC AGM2-11-PKZ2017115 1 off Differential remote indication:a) General trip indication “+”, overload,b) Short-circuit releases Can be fitted to circuit-breakers and (high-capacity) compact starters, Can be combined with standard auxiliary contacts NHI… or NHI…S Short-circuit indicators 2 For motor-protective circuit-breaker, circuit-breakers and (high-capacity) compact starters – – – K-AGM-PKZ2021861 5 off Local short-circuit indication by indicator, can be reset. Can be used in circuit-breakers and (high-capacity) compact starters Current limiters Increase the switching capacity of non auto-protected motor-protective circuit-breakers to 100 kA/500 V – – – CL-PKZ2076439 1 off Max. rated operating voltage U e  = 690 V Rated uninterrupted current I u  = 40 A Can be retrofitted to circuit-breaker or separately positioned with EZ base Can be used for individual protection When fitting to circuit-breaker, clip plate C-PKZ2 always required Information relevant for export to North America 1) 2) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification  UL Listed, CSA certified Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking CSA File No. 1017555 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified NHI11 L1L2L3 NHI22 NHI11 1.13 1.14 1.21 1.22 1.21 1.13 1.14 1.22 1.31 1.32 1.43 1.44 PKZ2(4)/ZM... I  oder Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 7 Remote operators → 7/62 Additional accessories → 7/56 1 7 Accessories Page 2 (High-capacity) compact starter → 7/517 Remote operators → 7/62 9 Clip plate → 7/69 Additional accessories → 7/56 2 7 9 L1L2L3 NHI2-11S NHI11 L1L2L3 I  13 PKZ 2(4)/ZM.../S A1 14 21 22 A2 NHI 2-11S NHI 11S NHI 22S 1.13 1.13 1.21 1.13 1.31 31 1.21 43 1.43 1.21 1.14 1.14 1.22 1.14 1.32 32 1.22 44 1.44 1.22 I  L1L2L3 NHI2-11S L1L2L3 AGM   Trip"+" "I "   4.43 4.31 4.21 4.13 4.44 4.32 4.22 4.14 PKZ2(4)/ZM... AGM 2-11 "+" I  L1L2L3 "+" "    " On/Off L1L2L3 "+" "    " Trip "+" L T I   Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 9 Clip plate → 7/69 Additional accessories → 7/56 1 9 7/59 NHI…-PKZ2 HPL07058EN NHI…-PKZ2 HPL07059EN

7/58 Motor-protective circuit-breakers PKZ2 Accessories 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Accessories Accessories Contact configuration Contact sequence Circuit diagrams Part no.Article no. Price See price list Std. pack Notes Notes N/O = normally open contact NC = normally closed contact Standard auxiliary contacts 1 For motor-protective circuit-breaker, circuit-breakers and (high-capacity) compact starters 1 N/O 1 NC NHI11-PKZ2090677 1 off Can be fitted to circuit-breakers and (high-capacity) compact starters. Can be combined with trip-indicating auxiliary contacts AGM 2 N/O 2 NC NHI22-PKZ2097796 1 off For compact starters 1 N/O 1 NC NHI11S-PKZ2007623 1 off Can be fitted to starter combinations Can be combined with AGM trip-indicating auxiliary contacts 2 N/O 2 NC NHI22S-PKZ2000504 1 off 2 x 1 N/O 2 x 1 NC NHI2-11S-PKZ2009996 1 off Trip indicating auxiliary contacts with short-circuit indicator 1 For motor-protective circuit-breaker, circuit-breakers and (high-capacity) compact starters 2 x 1 N/O 2 x 1 NC AGM2-11-PKZ2017115 1 off Differential remote indication:a) General trip indication “+”, overload,b) Short-circuit releases Can be fitted to circuit-breakers and (high-capacity) compact starters, Can be combined with standard auxiliary contacts NHI… or NHI…S Short-circuit indicators 2 For motor-protective circuit-breaker, circuit-breakers and (high-capacity) compact starters – – – K-AGM-PKZ2021861 5 off Local short-circuit indication by indicator, can be reset. Can be used in circuit-breakers and (high-capacity) compact starters Current limiters Increase the switching capacity of non auto-protected motor-protective circuit-breakers to 100 kA/500 V – – – CL-PKZ2076439 1 off Max. rated operating voltage U e  = 690 V Rated uninterrupted current I u  = 40 A Can be retrofitted to circuit-breaker or separately positioned with EZ base Can be used for individual protection When fitting to circuit-breaker, clip plate C-PKZ2 always required Information relevant for export to North America 1) 2) Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification  UL Listed, CSA certified Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking CSA File No. 1017555 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified NHI11 L1L2L3 NHI22 NHI11 1.13 1.14 1.21 1.22 1.21 1.13 1.14 1.22 1.31 1.32 1.43 1.44 PKZ2(4)/ZM... I  oder Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 7 Remote operators → 7/62 Additional accessories → 7/56 1 7 Accessories Page 2 (High-capacity) compact starter → 7/517 Remote operators → 7/62 9 Clip plate → 7/69 Additional accessories → 7/56 2 7 9 L1L2L3 NHI2-11S NHI11 L1L2L3 I  13 PKZ 2(4)/ZM.../S A1 14 21 22 A2 NHI 2-11S NHI 11S NHI 22S 1.13 1.13 1.21 1.13 1.31 31 1.21 43 1.43 1.21 1.14 1.14 1.22 1.14 1.32 32 1.22 44 1.44 1.22 I  L1L2L3 NHI2-11S L1L2L3 AGM   Trip"+" "I "   4.43 4.31 4.21 4.13 4.44 4.32 4.22 4.14 PKZ2(4)/ZM... AGM 2-11 "+" I  L1L2L3 "+" "    " On/Off L1L2L3 "+" "    " Trip "+" L T I   Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 9 Clip plate → 7/69 Additional accessories → 7/56 1 9 7/59 NHI…-PKZ2 HPL07058EN NHI…-PKZ2 HPL07059EN

7/60 Motor-protective circuit-breakers PKZ2 Accessories 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Accessories Accessories Circuit diagrams Contact sequence Actuating voltage Voltage and frequency combination that can be implemented with a voltage trigger coil Part no.Article no. Price See price list Std. pack Notes Notes Shunt release (for power circuit-breakers) For AC and DC voltage A-PKZ2-A063967 1 off Can be fitted to motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Can be combined with remote operator. A-PKZ2-B063964 1 off A-PKZ2-C063930 1 off Undervoltage releases, non-delayed Without auxiliary contacts For AC – U-PKZ2(230V50HZ,240V60HZ)065766 1 off Can be fitted to motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Can be combined with remote operator. When combined with circuit-breaker can be used as emergency switching off device to IEC/EN 60204. For DC – U-PKZ2(24VDC)014463 1 off With auxiliary contact for AC – U-HI20-PKZ2(230V50HZ,240V60HZ)065768 1 off Can be fitted to motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Can be combined with remote operator.Two early-make N/O contacts built in.When combined with circuit-breaker, can be used as emergency switching off device to IEC/EN 60204.When the circuit-breaker is in the tripped position “+”, the auxiliary contacts are closed.The undervoltage release can be energized early with an additional bridge (see circuit diagram). This function cannot be used in combination with RE/RS-PKZ2 (remote operator). Undervoltage releases off-delayed, delay time 200 ms With auxiliary contact for AC – UVHI-PKZ2(230V50HZ,240V60HZ)065770 1 off Can be fitted to motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Can be combined with remote operator.Two early-make N/O contacts built in.Voltage drops ≦ 200 ms do not cause opening; contact time 200 ms when switching on. When the circuit-breaker is in the tripped position “+”, the auxiliary contacts are closed. Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified C1 C2 24 V DC 48 V DC 60V DC 24 V 50 Hz 48 V 50 Hz 24 V 60 Hz 48 V 60 Hz Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 7 Remote operators → 7/62 Additional accessories → 7/56 1 7 Accessories Page 2 (High-capacity) compact starter → 7/51 7 Remote operators → 7/62 9 Clip plate → 7/69 Additional accessories → 7/56 Further actuating voltages → 7/70 2 9 7 110 V DC 125 V DC 250 V DC 110 V 50 Hz 127 V 50 Hz 220 V 50 Hz 230 V 50 Hz 240 V 50 Hz 110 V 60 Hz 120 V 60 Hz 208 V 60 Hz 220 V 60 Hz 240 V 60 Hz 380 V 50 Hz 400 V 50 Hz 415 V 50 Hz 440 V 50 Hz 500 V 50Hz 480 V 60 Hz 600 V 60 Hz U  D1 D2 U  D1 D2 2.14 2.13 2.23 2.24 L1L2L3 HI20 On L1L2L3 HI20 Off/Trip U  D1 2.13 2.14 D2 L1L2L3 UVHI On L1L2L3 UVHI Ausschalten/Auslösen 7/61 A-PKZ..., U-PKZ... HPL07060EN A-PKZ..., U-PKZ... HPL07061EN

7/60 Motor-protective circuit-breakers PKZ2 Accessories 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Accessories Accessories Circuit diagrams Contact sequence Actuating voltage Voltage and frequency combination that can be implemented with a voltage trigger coil Part no.Article no. Price See price list Std. pack Notes Notes Shunt release (for power circuit-breakers) For AC and DC voltage A-PKZ2-A063967 1 off Can be fitted to motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Can be combined with remote operator. A-PKZ2-B063964 1 off A-PKZ2-C063930 1 off Undervoltage releases, non-delayed Without auxiliary contacts For AC – U-PKZ2(230V50HZ,240V60HZ)065766 1 off Can be fitted to motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Can be combined with remote operator. When combined with circuit-breaker can be used as emergency switching off device to IEC/EN 60204. For DC – U-PKZ2(24VDC)014463 1 off With auxiliary contact for AC – U-HI20-PKZ2(230V50HZ,240V60HZ)065768 1 off Can be fitted to motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Can be combined with remote operator.Two early-make N/O contacts built in.When combined with circuit-breaker, can be used as emergency switching off device to IEC/EN 60204.When the circuit-breaker is in the tripped position “+”, the auxiliary contacts are closed.The undervoltage release can be energized early with an additional bridge (see circuit diagram). This function cannot be used in combination with RE/RS-PKZ2 (remote operator). Undervoltage releases off-delayed, delay time 200 ms With auxiliary contact for AC – UVHI-PKZ2(230V50HZ,240V60HZ)065770 1 off Can be fitted to motor-protective circuit-breakers, circuit-breakers, and (high-capacity) compact starters Can be combined with remote operator.Two early-make N/O contacts built in.Voltage drops ≦ 200 ms do not cause opening; contact time 200 ms when switching on. When the circuit-breaker is in the tripped position “+”, the auxiliary contacts are closed. Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified C1 C2 24 V DC 48 V DC 60V DC 24 V 50 Hz 48 V 50 Hz 24 V 60 Hz 48 V 60 Hz Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 7 Remote operators → 7/62 Additional accessories → 7/56 1 7 Accessories Page 2 (High-capacity) compact starter → 7/51 7 Remote operators → 7/62 9 Clip plate → 7/69 Additional accessories → 7/56 Further actuating voltages → 7/70 2 9 7 110 V DC 125 V DC 250 V DC 110 V 50 Hz 127 V 50 Hz 220 V 50 Hz 230 V 50 Hz 240 V 50 Hz 110 V 60 Hz 120 V 60 Hz 208 V 60 Hz 220 V 60 Hz 240 V 60 Hz 380 V 50 Hz 400 V 50 Hz 415 V 50 Hz 440 V 50 Hz 500 V 50Hz 480 V 60 Hz 600 V 60 Hz U  D1 D2 U  D1 D2 2.14 2.13 2.23 2.24 L1L2L3 HI20 On L1L2L3 HI20 Off/Trip U  D1 2.13 2.14 D2 L1L2L3 UVHI On L1L2L3 UVHI Ausschalten/Auslösen 7/61 A-PKZ..., U-PKZ... HPL07060EN A-PKZ..., U-PKZ... HPL07061EN

7/62 Motor-protective circuit-breakers PKZ2 Remote operators 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Remote operators Remote operators Circuit diagrams Circuit diagram for pulsed operation Part no.Article no. Price See price list Std. pack Notes Notes OFF and RESET separate OFF equals RESET RE-PKZ2 remote operator Actuation through auxiliary contact Power and control sections (line and control) have the same reference potential. Pulsed actuation (≧ 2 VA/W, 15 ms) and two-wire control actuation are possible. Upon activation, the power section is supplied with power directly from the mains (700 VA/W, 30 ms). The control section can be actuated through NHI, AGM, ETS4-VS3, M22-(C)K…, PLC with floating contacts without RC suppressor circuit. RE-PKZ2(220-240V50/60HZ,DC)063676 1 off Can be fitted to circuit-breakers and (high-power) compact starters. Switches circuit-breakers ON/OFF remotely (or OFF after tripping).Remote operator can be switched off locally and the thumb-grip locked with a 6 mm padlock.Suitable for AC or DC voltage.Can be combined with voltage release U, U-HI20, UVHI-PKZ2 or A-PKZ2.Standard auxiliary contact NHI is always required for the combination of circuit-breaker and Remote operator RE/RS-PKZ2.Cannot be combined with door coupling handle PKZ2-X(R)H. .Mounting possible in switch position.Internal electronic interlock always prioritizes “OFF”.Green slider position ≙ ,"Manual" position (33/34) open.Red slider position ≙ ,"Auto" position (33/34) closed.In “manual” position remote switching is not possible. RE-PKZ2(110-120V50/60HZ,DC)063673 1 off RE-PKZ2(24V50/60HZ,DC)063670 1 off Actuation through PLC semiconductor outputs – The power section and control section (line and control) are galvanically isolated from each other. Control section always 24 V. Safe isolation between the power section and control section is guaranteed. Pulsed (≧ 2 VA/W, 15 ms) and two-wire control activation are possible. The control section can be actuated directly through PLC electronic outputs (24 VDC). When actuated, the power section is supplied with power directly from the mains (700VA/W, 30 ms). RS-PKZ2(220-240V50/60HZ,DC)063688 1 off – RS-PKZ2(380-415V50/60HZ)063689 1 off – RS-PKZ2(24V50/60HZ,DC)063682 1 off Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified 72 A20 74 L A40 B20 T I  L(+) N(-) 72 74 A20 A40 B20 O I 33 34 LINE CONTROL ON OFF RESET L(+) N(-) 72 74 A20 A40 B20 O I 33 34 LINE CONTROL ON OFF RESET Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 3 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/58 Additional accessories → 7/56 1 3 5 Accessories Page 2 (High-capacity) compact starter → 7/51 4 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/58 9 Clip plate → 7/69 2 4 5 9 Minimum command time: f  15 O I t (ms) I O t (ms) I O t (ms) CONTROL ON LINE CONTROL ON OFF/RESET CONTROL OFF/RESET ON OFF f  15 f  300 F  30 F  30 Main contact 72 74 A20 A30 A0 L T I  L(+) N(-) 72 74 33 34 A20 A30 A0 24V DC LINE CONTROL OFF/RESET ON L(+) N(-) 72 74 33 34 A20 A30 A0 I O 24V DC AC/DC LINE CONTROL OFF/RESET ON 7/63 RE-PKZ, RS-PKZ HPL07062EN RE-PKZ, RS-PKZ HPL07063EN

7/62 Motor-protective circuit-breakers PKZ2 Remote operators 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Remote operators Remote operators Circuit diagrams Circuit diagram for pulsed operation Part no.Article no. Price See price list Std. pack Notes Notes OFF and RESET separate OFF equals RESET RE-PKZ2 remote operator Actuation through auxiliary contact Power and control sections (line and control) have the same reference potential. Pulsed actuation (≧ 2 VA/W, 15 ms) and two-wire control actuation are possible. Upon activation, the power section is supplied with power directly from the mains (700 VA/W, 30 ms). The control section can be actuated through NHI, AGM, ETS4-VS3, M22-(C)K…, PLC with floating contacts without RC suppressor circuit. RE-PKZ2(220-240V50/60HZ,DC)063676 1 off Can be fitted to circuit-breakers and (high-power) compact starters. Switches circuit-breakers ON/OFF remotely (or OFF after tripping).Remote operator can be switched off locally and the thumb-grip locked with a 6 mm padlock.Suitable for AC or DC voltage.Can be combined with voltage release U, U-HI20, UVHI-PKZ2 or A-PKZ2.Standard auxiliary contact NHI is always required for the combination of circuit-breaker and Remote operator RE/RS-PKZ2.Cannot be combined with door coupling handle PKZ2-X(R)H. .Mounting possible in switch position.Internal electronic interlock always prioritizes “OFF”.Green slider position ≙ ,"Manual" position (33/34) open.Red slider position ≙ ,"Auto" position (33/34) closed.In “manual” position remote switching is not possible. RE-PKZ2(110-120V50/60HZ,DC)063673 1 off RE-PKZ2(24V50/60HZ,DC)063670 1 off Actuation through PLC semiconductor outputs – The power section and control section (line and control) are galvanically isolated from each other. Control section always 24 V. Safe isolation between the power section and control section is guaranteed. Pulsed (≧ 2 VA/W, 15 ms) and two-wire control activation are possible. The control section can be actuated directly through PLC electronic outputs (24 VDC). When actuated, the power section is supplied with power directly from the mains (700VA/W, 30 ms). RS-PKZ2(220-240V50/60HZ,DC)063688 1 off – RS-PKZ2(380-415V50/60HZ)063689 1 off – RS-PKZ2(24V50/60HZ,DC)063682 1 off Information relevant for export to North America Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified 72 A20 74 L A40 B20 T I  L(+) N(-) 72 74 A20 A40 B20 O I 33 34 LINE CONTROL ON OFF RESET L(+) N(-) 72 74 A20 A40 B20 O I 33 34 LINE CONTROL ON OFF RESET Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 3 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/58 Additional accessories → 7/56 1 3 5 Accessories Page 2 (High-capacity) compact starter → 7/51 4 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/58 9 Clip plate → 7/69 2 4 5 9 Minimum command time: f  15 O I t (ms) I O t (ms) I O t (ms) CONTROL ON LINE CONTROL ON OFF/RESET CONTROL OFF/RESET ON OFF f  15 f  300 F  30 F  30 Main contact 72 74 A20 A30 A0 L T I  L(+) N(-) 72 74 33 34 A20 A30 A0 24V DC LINE CONTROL OFF/RESET ON L(+) N(-) 72 74 33 34 A20 A30 A0 I O 24V DC AC/DC LINE CONTROL OFF/RESET ON 7/63 RE-PKZ, RS-PKZ HPL07062EN RE-PKZ, RS-PKZ HPL07063EN

7/64 Motor-protective circuit-breakers PKZ2 Contact modules 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Contact modules Contact modules Circuit diagrams Max. motor rating Auxiliary contacts For use with Part no.Article no. Price See price list Std. pack Notes Notes AC-3 N/O = normally open contact NC = normally closed contact 220 V230 V240 V 380 V400 V415 V  440 V  500 V 660 V690 V P P P P P kW kW kW kW kW Contact modules – 11 20 22 24 30 1  N/O 1  NC PKZ2(4) SE1A/11-PKZ2(230V50HZ,240V60HZ)063711 1 off Order clip plate for snap-fitting the combination separately. Can be fitted to 3 or 4 pole circuit-breaker. When combined with a clip plate, can be snap-fitted to one or two IEC/EN 60715 top-hat rails with 15 mm height.Can be mounted separately using base (see below), RC suppressor on request.DC version: The coil cannot be changed.  Built-in auxiliary contact  HI10-S-PKZ2 can be switched freely. The auxiliary contact cannot be changed. DC version with suppressor circuit (varistor suppressor).High-capacity contact modules with serial no. 01 suitable for mounting with MV‐PKZ2. – 11 20 22 24 30 2  N/O – PKZ2(4) SE1A/20-PKZ2(230V50HZ,240V60HZ)063718 1 off – 11 20 22 24 30 1  N/O – PKZ2(4) SE1A-G-10-PKZ2(24VDC)058856 1 off High-capacity contact module, with current limiting contacts 1) – 11 20 22 24 30 1  N/O 1  NC PKZ2(4) S-PKZ2(230V50HZ,240V60HZ)063696 1 off Order clip plate for snap-fitting the combination separately. Can be fitted to 3 or 4 pole circuit-breaker. When combined with a clip plate, can be snap-fitted to one or two IEC/EN 60715 top-hat rails with 15 mm height.Can be mounted separately using base (see below), RC suppressor on request.A coil change is not possible, the integrated HI10-S-PKZ2 auxiliary contact can be switched freely, an auxiliary contact change is not possible. With suppressor circuit (varistor suppressor).High-capacity contact modules with serial no. 01 suitable for mounting with MV‐PKZ2. – 11 20 22 24 30 2  N/O – PKZ2(4) S/HI20-S-PKZ2(230V50HZ,240V60HZ)063703 1 off – 11 20 22 24 30 1  N/O – PKZ2(4) S-G-PKZ2(24VDC)070921 1 off Varistor suppressor 24 - 48 V AC – – – – – – – S(E1A)-…-PKZ2 VGSPKZ48063974 10 off For (high-power) contact modules with AC actuation, 50 - 60 Hz 110 - 250 V AC – – – – – – – S(E1A)-…-PKZ2 VGSPKZ250063973 10 off Bases for separate mounting 2) – – – – – – – – – S(E1A)-…-PKZ2CL-PKZ2 EZ-PKZ2028596 1 off For retrofitting of (high-capacity) contact module or current limiter, separate mounting When mounting separately, also functions as mounting base for auxiliary contact HI11-S/EZ-PKZ2. Can be snap-fitted on IEC/EN 60715 top-hat rail, or optional M4 screw fixing Information relevant for export to North America 1)Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified See also → Page 7/75 2)Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified T 13 21 22 14 A2 A1 Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 3 Standard auxiliary contacts → 7/58 4 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/586 Shunt releases, undervoltage releases → 7/60 7 Remote operators → 7/62 9 Clip plate → 7/69 Further actuation voltages → 7/71 Additional accessories → 7/56 5 3 4 9 1 7 6 T 13 23 14 24 A1 A2 T 13 14 A1 24 V DC A2 T 13 14 22 A1 A2 21 I  T 13 23 14 24 A1 A2 I  T A2 13 14 24 V DC A1 I  A1 A2 7/65 SE.../...-PKZ, VGSPKZ HPL07064EN SE.../...-PKZ, VGSPKZ HPL07065EN

7/64 Motor-protective circuit-breakers PKZ2 Contact modules 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Contact modules Contact modules Circuit diagrams Max. motor rating Auxiliary contacts For use with Part no.Article no. Price See price list Std. pack Notes Notes AC-3 N/O = normally open contact NC = normally closed contact 220 V230 V240 V 380 V400 V415 V  440 V  500 V 660 V690 V P P P P P kW kW kW kW kW Contact modules – 11 20 22 24 30 1  N/O 1  NC PKZ2(4) SE1A/11-PKZ2(230V50HZ,240V60HZ)063711 1 off Order clip plate for snap-fitting the combination separately. Can be fitted to 3 or 4 pole circuit-breaker. When combined with a clip plate, can be snap-fitted to one or two IEC/EN 60715 top-hat rails with 15 mm height.Can be mounted separately using base (see below), RC suppressor on request.DC version: The coil cannot be changed.  Built-in auxiliary contact  HI10-S-PKZ2 can be switched freely. The auxiliary contact cannot be changed. DC version with suppressor circuit (varistor suppressor).High-capacity contact modules with serial no. 01 suitable for mounting with MV‐PKZ2. – 11 20 22 24 30 2  N/O – PKZ2(4) SE1A/20-PKZ2(230V50HZ,240V60HZ)063718 1 off – 11 20 22 24 30 1  N/O – PKZ2(4) SE1A-G-10-PKZ2(24VDC)058856 1 off High-capacity contact module, with current limiting contacts 1) – 11 20 22 24 30 1  N/O 1  NC PKZ2(4) S-PKZ2(230V50HZ,240V60HZ)063696 1 off Order clip plate for snap-fitting the combination separately. Can be fitted to 3 or 4 pole circuit-breaker. When combined with a clip plate, can be snap-fitted to one or two IEC/EN 60715 top-hat rails with 15 mm height.Can be mounted separately using base (see below), RC suppressor on request.A coil change is not possible, the integrated HI10-S-PKZ2 auxiliary contact can be switched freely, an auxiliary contact change is not possible. With suppressor circuit (varistor suppressor).High-capacity contact modules with serial no. 01 suitable for mounting with MV‐PKZ2. – 11 20 22 24 30 2  N/O – PKZ2(4) S/HI20-S-PKZ2(230V50HZ,240V60HZ)063703 1 off – 11 20 22 24 30 1  N/O – PKZ2(4) S-G-PKZ2(24VDC)070921 1 off Varistor suppressor 24 - 48 V AC – – – – – – – S(E1A)-…-PKZ2 VGSPKZ48063974 10 off For (high-power) contact modules with AC actuation, 50 - 60 Hz 110 - 250 V AC – – – – – – – S(E1A)-…-PKZ2 VGSPKZ250063973 10 off Bases for separate mounting 2) – – – – – – – – – S(E1A)-…-PKZ2CL-PKZ2 EZ-PKZ2028596 1 off For retrofitting of (high-capacity) contact module or current limiter, separate mounting When mounting separately, also functions as mounting base for auxiliary contact HI11-S/EZ-PKZ2. Can be snap-fitted on IEC/EN 60715 top-hat rail, or optional M4 screw fixing Information relevant for export to North America 1)Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified See also → Page 7/75 2)Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified T 13 21 22 14 A2 A1 Accessories Page 1 Motor-protective circuit-breaker, circuit-breakers → 7/48 3 Standard auxiliary contacts → 7/58 4 Standard auxiliary contacts → 7/58 5 Trip-indicating auxiliary contact → 7/586 Shunt releases, undervoltage releases → 7/60 7 Remote operators → 7/62 9 Clip plate → 7/69 Further actuation voltages → 7/71 Additional accessories → 7/56 5 3 4 9 1 7 6 T 13 23 14 24 A1 A2 T 13 14 A1 24 V DC A2 T 13 14 22 A1 A2 21 I  T 13 23 14 24 A1 A2 I  T A2 13 14 24 V DC A1 I  A1 A2 7/65 SE.../...-PKZ, VGSPKZ HPL07064EN SE.../...-PKZ, VGSPKZ HPL07065EN

7/66 Motor-protective circuit-breakers PKZ2 Accessories for contact modules 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Accessories for contact modules Accessories for contact modules Contact configuration Contact sequence Circuit diagrams Part no.Article no. Price See price list Std. pack Notes Information relevant for export to North America N/O = normally open contact NC = normally closed contact Control cable connection – – – – ST-PKZ2010998 3 off 1 set = 2 offVDE/IEC and UL/CSA compliantConnection option for fast-on connectors (insulated/non-insulated) 2.8 mmMax. cross-section 0.5 - 1 mm 2 , 20 - 16 AWG Max. current tap off  1 A or 15 % of the set valueIncrease setting of thermal release accordingly.Enables control circuit supply to be tapped off between motor-protective circuit-breaker or circuit-breaker and (high-capacity) contact module. Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking Auxiliary contacts for (high-capacity) contact module, separate mounting  Can be fitted on side of base for separate mounting  1 N/O 1 NC HI11-S/EZ-PKZ2090305 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Auxiliary contacts for (high-capacity) contact module Auxiliary contacts for exchange of integrated auxiliary contact in (high-capacity) contact moduleExchange not possible with contact module SE1A-G-10-PKZ2 or high-capacity contact module S-G-PKZ2 1 N/O 1 NC – – HI11-S-PKZ2033936 1 off 2 N/O – – – HI20-S-PKZ2033935 1 off Mechanical interlock For mechanically interlocking two separately mounted (high-capacity) contact modules or two (high-capacity) compact starters.4 end brackets are includedCan be combined with high-capacity contact module S-PKZ2 with serial no. 01 – – – – MV-PKZ2033938 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified L1L2L3 HI On L1L2L3 HI Off 32 44 31 43 Accessories Page 8 High-capacity contact modules → 7/64 10 Base for separate mounting → 7/64 Further actuating voltages → 7/70 10 8 7/67 HI...-PKZ2 HPL07066EN HI...-PKZ2 HPL07067EN

7/66 Motor-protective circuit-breakers PKZ2 Accessories for contact modules 2010 CA08103002Z-EN www.eaton.com 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers PKZ2 Accessories for contact modules Accessories for contact modules Contact configuration Contact sequence Circuit diagrams Part no.Article no. Price See price list Std. pack Notes Information relevant for export to North America N/O = normally open contact NC = normally closed contact Control cable connection – – – – ST-PKZ2010998 3 off 1 set = 2 offVDE/IEC and UL/CSA compliantConnection option for fast-on connectors (insulated/non-insulated) 2.8 mmMax. cross-section 0.5 - 1 mm 2 , 20 - 16 AWG Max. current tap off  1 A or 15 % of the set valueIncrease setting of thermal release accordingly.Enables control circuit supply to be tapped off between motor-protective circuit-breaker or circuit-breaker and (high-capacity) contact module. Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking Auxiliary contacts for (high-capacity) contact module, separate mounting  Can be fitted on side of base for separate mounting  1 N/O 1 NC HI11-S/EZ-PKZ2090305 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified Auxiliary contacts for (high-capacity) contact module Auxiliary contacts for exchange of integrated auxiliary contact in (high-capacity) contact moduleExchange not possible with contact module SE1A-G-10-PKZ2 or high-capacity contact module S-G-PKZ2 1 N/O 1 NC – – HI11-S-PKZ2033936 1 off 2 N/O – – – HI20-S-PKZ2033935 1 off Mechanical interlock For mechanically interlocking two separately mounted (high-capacity) contact modules or two (high-capacity) compact starters.4 end brackets are includedCan be combined with high-capacity contact module S-PKZ2 with serial no. 01 – – – – MV-PKZ2033938 1 off Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E29184 UL CCN NKCR CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified L1L2L3 HI On L1L2L3 HI Off 32 44 31 43 Accessories Page 8 High-capacity contact modules → 7/64 10 Base for separate mounting → 7/64 Further actuating voltages → 7/70 10 8 7/67 HI...-PKZ2 HPL07066EN HI...-PKZ2 HPL07067EN

7/68 Motor-protective circuit-breakers PKZ2 Busbar adapters 2010 CA08103002Z-EN www.eaton.com Busbar adapters Rated operating voltage Cable cross-section Adapter width Mounting rails For use with Part no.Article no. PriceSee price list Std. pack Notes U e V  mm Number Busbar adapters for PKZ Approved to UL 508.For fitting to flat copper busbar with 60 mm between busbar centers, suitable for 5 mm and 10 mm busbar thickness. Rated operational current 63 A For motor-protective circuit breakers. 690 AWG 8(10 mm²) 72 1 PKZ2 BBA2-63 1) 101458 4 Off – 690 AWG 8(10 mm²) 54 1 PKZM4 BBA4-63 1) 101457 4 Off – For DOL starters. 690 AWG 8(10 mm²) 72 2 PKZ2 + DILM7PKZ2 + DILM9PKZ2 + DILM12PKZ2 + DILM15PKZ2 + DILM17PKZ2 + DILM25PKZ2 + DILM32PKZ2 + DILM40 BBA2L-63 1) 101480 2 Off – 690 AWG 8(10 mm²) 55 2 PKZM4 + DILM17PKZM4 + DILM25PKZM4 + DILM32PKZM4 + DILM40PKZM4 + DILM50PKZM4 + DILM65 BBA4L-63 1) 101459 4 Off The following can be used for an electrical connection:PKZM4 + DILM40 bis DILM65: PKZM4-XM65DEusable. 690 AWG 8(10 mm²) 72 2 PKZ2 + DILM7PKZ2 + DILM9PKZ2 + DILM12PKZ2 + DILM15PKZ2 + DILM17PKZ2 + DILM25PKZ2 + DILM32PKZ2 + DILM38PKZ2 + DILM40PKZ2 + DILM50PKZ2 + DILM65SE1A/…-PKZ2 + C-PKZ2S-PKZ2 + C-PKZ2 BBA2-63/2TS 2) 116900 4 Off For DOL starters. Rated operational current 80 A Can be used universally. 690 – 72 2 PKZ2 + DILM7PKZ2 + DILM9PKZ2 + DILM12PKZ2 + DILM15PKZ2 + DILM17PKZ2 + DILM25PKZ2 + DILM32PKZ2 + DILM38PKZ2 + DILM40PKZ2 + DILM50PKZ2 + DILM65 BBA2-80/2TS-S 2) 116901 4 Off Universal adapter for 1, 2 and 3-phase applications, not suitable without additional UL/CSA component.For conductor cross-section, round conductors up to 16 mm 2  or AWG6. NotesInformation relevant for export to North America 1)  Product Standards UL 508A; CSA-C22.2 No. 14; IEC60439-1; CE marking UL File No. E300273 UL CCN NMTR CSA File No. 232140 CSA Class No. 3211-37 NA Certification UL Recognized, CSA certified Max. Voltage Rating 600 V AC 2) Product Standards UL 508A; CSA-C22.2 No. 14; IEC60439-1; CE marking UL File No. E300273 UL CCN NMTR NA Certification UL Recognized, CSA certified Max. Voltage Rating 600 V AC BBA HPL07068EN

Motor-protective circuit-breakers PKZ2 Accessories 2010 CA08103002Z-EN www.eaton.com 7/69 Accessories For use with Part no.Article no. Price See price list Std. pack Notes Clip plate For optional snap-on and M4 screw fixing for circuit-breakers with (high-power) contact module or current limiter Can be used with busbar adapter C-PKZ2052710 2 Off Can be snap-fitted to one IEC/EN 60715 top-hat rails with 15 mm height or two top-hat rails exceeding 10 mm height UL/CSA certification not required Three-phase commoning links For wiring 3 PKZ2s, space is provided for either 2 auxiliary contacts or 2 voltage releases B3.1/3-PKZ2 1) 033940 5 Off Can be extended to several PKZ2s by rotated mounting, protected against accidental contactU e  = 690 V, I u  = 120 A, short-circuit proof For wiring of 2 PKZ2, space is provided for either 1 auxiliary contact or 1 shunt release B3.1/2-PKZ2 1) 063969 5 Off Supply terminal For three-phase commoning link, protected against accidental contactU e  = 690 V, I u  = 120 A  – BK50/3-PKZ2 2) 033941 2 Off For connection of: max. 1 x 50 mm 2  or 2 x 35 mm 2  above one another;  min. 1 x 1 mm 2  or 2 x 1 mm 2 Shroud for unused terminals Protection against direct contact.To cover unused terminals on three-phase commoning link – H-B3-PKZ2063968 10 Off Snap-fitting option must be available on the three-phase commoning link Padlocking feature For locking the circuit-breaker in the 0 position when the control panel door is open (rear-mounting type) – SVB-PKZ2 1) 050337 5 Off Suitable for 3 padlocks with 5 – 8 mm hasp thickness Coding pins For coding (in dual coding system) the devices assigned from trip block to PKZ2(4) basic device – CS-PKZ2 3) 055083 1 Off – Documentation PKZM2 motor-protective circuit breakers, overload monitoring of EEx e motors German/English AWB1210-1485D/GB266166 1 Off – Information relevant for export to North America 1)Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL Listed, CSA certified 2)Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. 98494 CSA Class No. 3211-06 NA Certification UL Listed, CSA certified 3)Product Standards UL 508; CSA-C22.2 No. 14;IEC60947-4-1; CE marking UL File No. E36332 UL CCN NLRV CSA File No. On request NA Certification UL Listed, CSA certified C-PKZ, B3..., PKZ HPL07069EN

7/70 Motor-protective circuit-breakers PKZ2 Actuating voltages 2010 CA08103002Z-EN www.eaton.com Compact starters Contact module with 1 normally open and 1 normally closed auxiliary contact AC PKZ2/ZM-1/SE1A/11(...) PKZ2/ZM-1.6/SE1A/11(...) PKZ2/ZM-2.4/SE1A/11(...) PKZ2/ZM-4/SE1A/11(...) PKZ2/ZM-6/SE1A/11(...) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Standard voltage See price list See price list See price list See price list See price list 230 V 50 Hz, 240 V 60 Hz 063364 063372 063382 063392 063402 110 V 50/60 Hz – – – – 063408 230 V 50/60 Hz 063369 063379 063389 063399 063409 Compact starters Contact module with 1 normally open and 1 normally closed auxiliary contact AC PKZ2/ZM-10/SE1A/11(...) PKZ2/ZM-16/SE1A/11(...) PKZ2/ZM-25/SE1A/11(...) PKZ2/ZM-32/SE1A/11(...) PKZ2/ZM-40/SE1A/11(...) PKZ2/SE1A/11(...) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Standard voltage See price list See price list See price list See price list See price list See price list 230 V 50 Hz,240 V 60 Hz 063412 063422 063432 063442 063452 082142 110 V 50/60 Hz 063418 063428 063438 063448 063458 – 230 V 50/60 Hz 063419 063429 063439 063449 063459 082148 High-capacity compact starters Contact module with 1 normally open and 1 normally closed auxiliary contact AC PKZ2/ZM-1/S(...) PKZ2/ZM-1.6/S(...) PKZ2/ZM-2.4/S(...) PKZ2/ZM-4/S(...) PKZ2/ZM-6/S(...) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Standard voltage See price list See price list See price list See price list See price list 230 V 50 Hz,240 V 60 Hz 063472 063482 063492 063502 063512 110 V 50/60 Hz 063478 063488 063498 063508 063518 230 V 50/60 Hz 063479 063489 063499 063509 063519 High-capacity compact starters Contact module with 1 normally open and 1 normally closed auxiliary contact AC PKZ2/ZM-10/S(...) PKZ2/ZM-16/S(...) PKZ2/ZM-25/S(...) PKZ2/ZM-32/S(...) PKZ2/ZM-40/S(...) PKZ2/S(...) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Standard voltage See price list See price list See price list See price list See price list See price list 110 V 50 Hz,120 V 60 Hz – – – – – 063570 230 V 50 Hz,240 V 60 Hz 063522 063532 063542 063552 063562 063572 24 V 50/60 Hz – – – – – 063577 110 V 50/60 Hz 063528 063538 063548 063558 063568 – 230 V 50/60 Hz 063529 063539 063549 063559 063569 063579 Notes 1)    To obtain the complete part number, append the actuating voltage (...) to the part nos. given above.  Devices with dual-voltage coils must be ordered with a single article no. PKZ.../S... HPL07070EN

Motor-protective circuit-breakers PKZ2 Actuating voltages 2010 CA08103002Z-EN www.eaton.com 7/71 Undervoltage release When ordered separately AC U-PKZ2(...) U-HI20-PKZ2(...) UVHI-PKZ2(...) Article no. 1) Article no. 1) Article no .1) Standard voltage See price list See price list See price list 24 V 50 Hz 055085 - – 110 V 50 Hz,120 V 60 Hz – 063655 – 220 V 50 Hz,240 V 60 Hz 065685 063656 – 230 V 50 Hz,240 V 60 Hz 065766 065768 065770 400 V 50 Hz,440 V 60 Hz 065767 – – 24 V 50/60 Hz – 063659 – Non-standard voltages with the exception of the shown standard voltages 2) . – See price list – ...V 50Hz (24 – 600 V) – 907537 3) – ...V 60Hz (24 – 600 V) – 907538 3) – DCStandard voltage See price list – – 24V DC 014463 – – 48V DC 028701 – – Notes 1)    To obtain the complete part number, append the actuating voltage (...) to the part nos. given above. Devices with  dual-voltage coils must be ordered with a single article no. 2)    For non-standard voltages, specify the required actuating voltage within the indicated range (... - ... V). 3)    Minimum order quantity: 10 units. (High-capacity) contact modules AC S-PKZ2(...) S/HI20-S-PKZ2(...) SE1A/11-PKZ2(...) SE1A/20-PKZ2(...) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Standard voltage See price list See price list See price list See price list 24 V 50 Hz 026609 – – – 48 V 50 Hz 062651 056383 – – 240 V 50 Hz 001882 057048 058716 058717 24 V 60 Hz 062501 – – – 110 V 50 Hz,120 V 60 Hz 063694 063701 063709 063716 190 V 50 Hz,220 V 60 Hz 063695 – 063710 063717 220 V 50 Hz,240 V 60 Hz 063699 063706 – – 230 V 50 Hz,240 V 60 Hz 063696 063703 063711 063718 400 V 50 Hz,440 V 60 Hz 063697 – 063712 063719 24 V 50/60 Hz 062500 – 058720 058721 110 V 50/60 Hz – – 058696 – 230 V 50/60 Hz 065103 056395 058712 058713 DC S-G-PKZ2(...) SE1A-G-10-PKZ2(...) Article no. 1) Article no. 1) Standard voltage See price list See price list 24 V DC 070921 058856 Notes 1)    To obtain the complete part number, append the actuating voltage (...) to the part nos. given above. Devices with  dual-voltage coils must be ordered with a single article no. U-PKZ, S-PKZ HPL07071EN

7/72 Motor-protective circuit-breakers PKZ2 Characteristic curves 2010 CA08103002Z-EN www.eaton.com Tripping characteristic curves,motor-protective circuit-breakers, (high-power) compact starters Tripping characteristic curves, line protection Let-through characteristics, circuit-breakers, compact starters Let-through characteristics, high-capacity compact starters and circuit-breakers + current limiters CL 2 5 20 50 200 1 2 5 10 20 40 1 2 5 2010 2h 1,5 2 3 4 6 8 10 15 20 30 PKZ2/ZM-... PKZ2/ZM-.../S PKZ2/ZM-.../SE1A Seconds Milliseconds Minutes x Rated operational current 2 5 20 50 200 1 2 5 10 20 40 1 2 5 20 10 2h 1,5 2 3 4 6 8 10 15 20 30 PKZ2/ZM-...-8 Seconds Milliseconds Minutes x Rated operational current PKZ2/ZM-...(-8) PKZ2/ZM-...(-8)/SE1A 1 1 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 32/40 A 25 A 16 A 10 A 6 A   2 ·  I cc U e  = 400 V [kA]   Î D I cc rms  [kA] 1 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 4 6 8 1.5 2 3 4 6 8 1.5 2 3 4 6 8 10 5 10 4 10 6 PKZ2/ZM-...(-8) PKZ2/ZM-...(-8)/SE1A 16 A 10 A 6 A 32/40 A25 A i  dt Z 2 [A  s] 2 U e  = 400 V [kA] 1 st  half-w ave I cc rms 1 1 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 PKZ2/ZM-...(-8)/S PKZ2/ZM-...(-8)/S-G PKZ2/ZM-...(-8)+CL PKZ2/ZM-.../S-SP 2 · I cc 32/40 A 25 A16 A10 A 6 A [kA]   Î D U e  = 400 V I cc rms  [kA] 1 st  half-w ave I cc rms 1 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 4 6 8 1.5 2 3 4 6 8 1,5 2 3 4 6 8 10 10 10 16 A 10 A PKZ2/ZM-...(-8)/S PKZ2/ZM-...(-8)/S-G PKZ2/ZM-...(-8)+CL PKZ2/ZM-.../S-SP 6 A 25 A 32 A 40 A [A  s] 2 U e  = 400 V [kA] y 5 4 6 Z PKZ2

Motor-protective circuit-breakers PKZ2 Characteristic curves 2010 CA08103002Z-EN www.eaton.com 7/73 Characteristic curves High-capacity contact module S-PKZ2, contact module SE1A-PKZ2 Normal switching duty Squirrel-cage motor Operating characteristics: Switch on: From standstill Switch off: While running Typical applications: CompressorsPumpsFansHinged flaps LiftsEscalatorsConveyor beltsBucket-elevator MixersAgitatorsCentrifugesAir-conditioning system General drives for manufacturing and processing machines Electrical Characteristic: Switch on:Switch off: Up to 6 x motor rated current1 x motor rated current Utilization category: 100 % AC-3 Extreme switching duty Squirrel-cage motor Operating characteristics: Inching, DC braking, reversing Typical applications: Printing machinesWire-drawing machinesCentrifugesSpecial drives formachining centers and machine tools Electrical Characteristic: Switch on:Switch off: 6 x motor rated current6 x motor rated current Utilization category: 100 % AC-4 Light switching duty Non-motor loads Operating characteristics: Non inductive and slightly inductive loads Typical applications: Electric heat Electrical Characteristic: Switch on:Switch off: Up to 1.5 x rated operational current Utilization category: 100 % AC-1 Determination of the maximum operating frequency dependant on the rating and utilization category (recommended values) for (high capacity) contact modules PN = max. motor rated output (kW)Ops/h = max. operations per hour 0.1 0.2  0.4  0.6  0.8  1  2 3  4  5  6  8  10  0.81  1.05  1.42  1.86  2.65  5.2  6.8  8.8  11.4  15.4  22.1  28.5  35  3.6  0.25  0.37  0.55  0.75  1.1  2.2  3  4  5.5  7.5  11  15  18.5  1.5  AC-3/400V  kW  A  S(E1A)-PKZ2  Rated output of three-phase  motors 50...60 Hz Component lifespan (millions of operations) Rated operational current  50...60 Hz Normal switching duty 0.81 1.05 1.42 1.86 2.65 5.2 6.8 8.8 11.4 15.4 22.1 28.5 35 3.6 0.25 0.37 0.55 0.75 1.1 2.2 3 4 5.5 7.5 11 15 18.5 1.5 AC-4/400V kW A 0.01 0.02 0.030.04 0.06 0.1 0.2 0.3 0.4 0.6 1 2 3 4 S(E1A)-PKZ2 5 Rated oper ational current  50...60 Hz Rated output of three-phase motors 50...60 Hz Component lifespan (millions of operations) Extreme switching duty 0.1 0.2 0.4 0.6 0.8 1 2 3 4 5 6 8 10 0.81 1.05 1.42 1.86 2.65 5.2 6.8 8.8 11.4 15.4 22.1 28.5 35 3.6 AC-1/400V S(E1A)-PKZ2 A 40 Breaking current Component lifespan (millions of operations) Non-motor loads, 3-pole 100 150 200 300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 7000 9000 10 0 20 30 40 50 60 70 80 90 100% AC-3 AC-4      (kW) N P Ops./h PKZ2

7/74 Motor-protective circuit-breakers PKZ2 Switching capacity 2010 CA08103002Z-EN www.eaton.com Switching capacity Motor-protective circuit-breakers, circuit-breaker Motor-protective circuit-breakerswitching capacity and (high-capacity) compact starter Rated uninterrupted current I u Rated conditional short-circuit current I q  IEC/EN 60947-4-1 Rated ultimate short-circuit breaking capacity I cu   IEC/EN 60947‐2 Rated breaking capacity I cs   } 230 V 400 V 440 V 500 V 690 V  I u I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs A kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) PKZ2/ZM with type “1” and “2” coordination0.16 – 1.6 N N N N N 2.4 N N N N N 4 N N N N 4.5 4.5 2.5 63 6 N N N N 4.5 4.5 2.5 80 10 30 N 30 N 10 10 5 80 7 7 3.5 80 4.5 4.5 2.5 80 16 30 N 30 N 10 10 5 100 7 7 3.5 100 4.5 4.5 2.5 100 25 30 30 7.5 160 30 30 7.5 160 10 10 5 125 7 7 3.5 125 4.5 4.5 2.5 125 32 30 30 7.5 160 30 30 7.5 160 10 10 5 160 7 7 3.5 160 4.5 4.5 2.5 160 40 30 30 7.5 160 30 30 7.5 160 10 10 5 160 7 7 3.5 160 4.5 4.5 2.5 160 PKZ2/ZM + CL-PKZ2 type “1” and “2” coordination0.16 – 1.6 N N N N N 2.4 N N N N N 4 N N N N 10 4.5 2.5 N 6 N N N N 10 4.5 2.5 N 10 30 N 30 N 5 N 3.5 N 10 4.5 2.5 N 16 30 N 30 N 5 N 3.5 N 10 4.5 2.5 N 25 7.5 N 7.5 N 5 N 3.5 N 10 4.5 2.5 N 32 7.5 N 7.5 N 5 N 3.5 N 10 4.5 2.5 N 40 7.5 N 7.5 N 5 N 3.5 N 10 4.5 2.5 N PKZ2/ZM(R)-.../SE1A(-G)... with type “1” of coordination0.16 – 1.6 N N N N N N N N N N N N N N N 2.4 N N N N N N N N N N N N N N N 4 N N N N N N N N N N N N 4.5 N N 63 6 N N N N N N N N N N N N 4.5 N N 80 10 N N N N N N 10 N N 80 7 N N 80 4.5 N N 80 16 N N N N N N 10 N N 100 7 N N 100 4.5 N N 100 25 30 N N 160 30 N N 160 10 N N 125 7 N N 125 4.5 N N 125 32 30 N N 160 30 N N 160 10 N N 160 7 N N 160 4.5 N N 160 40 30 N N 160 30 N N 160 10 N N 160 7 N N 160 4.5 N N 160 PKZ2/ZM-.../S(-G) with type “1” and “2” coordination0.6 – 2.4 N N N N N N N N N N 4 – 6 N N N N N N N N 10 N N 80 10 – 16 N N N N N N N N 10 N N 100 25 – 40 N N N N N N N N 10 N N 160 PKZ2/ZM-..-8 and PKZ2/ZM-..-8/SE1A(-G)0.16 – 1.6 N N N N N N N N N N 2.4 N N N N N N N N N N 4 N N N N N N N N N 4.5 2.5 63 6 N N N N N N N N N 4.5 2.5 80 10 N 30 N N 30 N N 10 5 80 N 7 3.5 80 N 4.5 2.5 80 16 N 30 N N 30 N N 10 5 100 N 7 3.5 100 N 4.5 2.5 100 25 N 30 7.5 160 N 30 7.5 160 N 10 5 125 N 7 3.5 125 N 4.5 2.5 125 32 N 30 7.5 160 N 30 7.5 160 N 10 5 160 N 7 3.5 160 N 4.5 2.5 160 40 N 30 7.5 160 N 30 7.5 160 N 10 5 160 N 7 3.5 160 N 4.5 2.5 160 PKZ2/ZM-...-8/S(-G) 0.6 – 2.4 N N N N N N N N N N 4 – 6 N N N N N N N N N 10 5 80 10 – 16 N N N N N N N N N 10 5 100 25 – 40 N N N N N N N N N 10 5 160 Notes   No upstream protective device required,as it is the auto-protected range (100 kA) 1) Fuse (A gG/gL) for increasing the switching capacity of the motor-protective circuit-breakerto 100 kA N Not necessary

Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breakers, circuit-breaker 2010 CA08103002Z-EN www.eaton.com 7/75 Approvals for world markets Approved rating data 1) UL 508/CSA C 22.2 No. 14 Maximum motor rating Setting ranges Maximum protective device to UL/CSA Three-phase current Overloadreleases Short-circuit-releases Group protection 1) Up to max.short-circuit rating Maximumfuse rating Maximumcircuitbreaker 200 V 230 V 460 V  575 V 480 V 600 V HP HP HP HP A A kA kA A A Motor-protective circuit-breakers PKZ2 “Manual Motor Starter with thermal and magnetic trip” PKZ2/ZM-0.6 2) 0.4 – 0.6 5 – 8 65 42 500 600 PKZ2/ZM-1 ½ ½ 0.6 – 1 8 – 14 65 42 500 600 PKZ2/ZM-1.6 ¾ 1 1 – 1.6 14 – 22 65 42 500 600 PKZ2/ZM-2.4 ½ ½ 1 1½ 1.6 – 2.4 20 – 35 65 42 500 600 PKZ2/ZM-4 1 1 2 3 2.4 – 4 35 – 55 65 42 500 600 PKZ2/ZM-6 1½ 1½ 3 5 4 – 6 50 – 80 65 42 500 600 PKZ2/ZM-10 2 3 5 7½ 6 – 10 80 – 140 65 42 500 600 PKZ2/ZM-16 3 5 10 10 10 – 16 130 – 220 65 42 500 600 PKZ2/ZM-25 7½ 7½ 20 25 16 – 27 200 – 350 65 42 500 600 PKZ2/ZM-32 10 10 20 30 24 – 32 275 – 425 65 42 500 600  PKZ2/ZM-40 10 15 30 30 32 – 42 350 – 500 65 42 500 600 High-power compact starters PKZ2 “Manual Motor Starter with thermal, magnetic trip and contactor” PKZ2/ZM-0.6/S(...) 2) 0.4 – 0.6 5 – 8 65 42 2000 2000 PKZ2/ZM-1/S(...) ½ ½ 0.6 – 1 8 – 14 65 42 2000 2000 PKZ2/ZM-1.6/S(...) ¾ 1 1 – 1.6 14 – 22 65 42 2000 2000 PKZ2/ZM-2.4/S(...) ½ ½ 1 1½ 1.6 – 2.4 20 – 35 65 42 2000 2000 PKZ2/ZM-4/S(...) 1 1 2 3 2.4 – 4 35 – 55 65 42 2000 2000 PKZ2/ZM-6/S(...) 1½ 1½ 3 5 4 – 6 50 – 80 65 42 2000 2000 PKZ2/ZM-10/S(...) 2 3 5 7½ 6 – 10 80 – 140 65 42 2000 2000 PKZ2/ZM-16/S(...) 3 5 10 10 10 – 16 130 – 220 65 42 2000 2000 PKZ2/ZM-25/S(...) 7½ 7½ 20 25 16 – 27 200 – 350 65 42 2000 2000 PKZ2/ZM-32/S(...) 10 10 20 30 24 – 32 275 – 425 65 42 2000 2000 PKZ2/ZM-40/S(...) 10 15 30 30 32 – 42 350 – 500 65 42 2000 2000 High-capacity contact modules "Contact module" in combination with PKZ2/ZM(R)-... motor-protective circuit-breakeror base for separate mounting of EZ-PKZ2 S-PKZ2(...) 10 15 30 30 S/HI20-S-PKZ2(...) 10 15 30 30 S-G-PKZ2(...) 10 15 30 30 Reversing combination "Reversing combination" in combination with trip block ZM-...PKZ2 for motor protection PKZ2/SW-MV-11(...) 10 15 30 30 Reversing busbar sys- 42 A 600 V AC A BK50/3-PKZ2 terminal must be ordered separately for UL/CSA use. 1) Caution: Changed requirements for group protection 2) Calculate motor power in this range according to the rated operational current. PKZ2, PKZ2....-CB

7/76 Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breakers 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers Approved rating data 1) Maximum motor rating Setting ranges UL 508/CSA C 22.2 No. 14 Three-phase current Overloadreleases Short-circuit-releases 200 V 230 V 460 V  575 V  208 V 240 V 480 V 600 V HP HP HP HP A A Basic device “Basic device“In connection with motor protection trip blockZM-...-PKZ2 ZMR -...-PKZ2 PKZ2 10 15 30 30 Motor protection trip modulewith overload relay function “Motor Protection Trip Module with overload relay function“ ZMR-0.6-PKZ2 2) 0.4 – 0.6 5 – 8 ZMR-1-PKZ2 ½ ½ 0.6 – 1 8 – 14 ZMR-1.6-PKZ2 ¾ 1 1 – 1.6 14 – 22 ZMR-2.4-PKZ2 ½ ½ 1 1½ 1.6 – 2.4 20 – 35 ZMR-4-PKZ2 1 1 2 3 2.4 – 4 35 – 55 ZMR-6-PKZ2 1½ 1½ 3 5 4 – 6 50 – 80 ZMR-10-PKZ2 2 3 5 7½ 6 – 10 80 – 140 ZMR-16-PKZ2 3 5 10 10 10 – 16 130 – 220 ZMR-25-PKZ2 7½ 7½ 20 25 16 – 27 200 – 350 ZMR-32-PKZ2 10 10 20 30 24 – 32 275 – 425 ZMR-40-PKZ2 10 15 30 30 32 – 42 350 – 500 Auxiliary contact ZMB  Pilot Duty D 300, R 300 General Purpose 1.5 A  240 V AC0.6 A  600 V AC Terminal capacity AWG 18 … 14 Torque 1 Nm/9 lb.-in Motor protectionTrip module ZM-1.6-PKZ2 2) 0.4 – 0.6 5 – 8 ZM-1-PKZ2 ½ ½ 0.6 – 1 8 – 14 ZM-1.6-PKZ2 ¾ 1 1 – 1.6 14 – 22 ZM-2.4-PKZ2 ½ ½ 1 1½ 1.6 – 2.4 20 – 35 ZM-4-PKZ2 1 1 2 3 2.4 – 4 35 – 55 ZM-6-PKZ2 1½ 1 3 5 4 – 6 50 – 80 ZM-10-PKZ2 2 3 5 7½ 6 – 10 80 – 140 ZM-16-PKZ2 3 5 10 10 10 – 16 130 – 220 ZM-25-PKZ2 7½ 7½ 20 25 16 – 27 200 – 350 ZM-32-PKZ2 10 10 20 30 24 – 32 275 – 425 ZM-40-PKZ2 10 15 30 30 32 – 42 350 – 500 Notes Service factor (SF) Set value I r  on the current scale  depending on the load factor 1) Devices for world markets IEC q UL/CSA. 2) Calculate motor power in this range according to the rated operational current. SF = 1.15 → I r  = 1 x I n mot Stated values to NEC  SF = 1 → I r  = 0.9 x I n mot Table 430 – 150. Terminal capacity High-capacity compact starters PKZ2/ZM-.../S,Motor-protective circuit-breakerPKZ2/ZM-...Cables Cu 75 °C, min. AWG 14,max. AWG 6 Torque 1.8 Nm PKZ2

Motor-protective circuit-breakers PKZ2 Accessories 2010 CA08103002Z-EN www.eaton.com 7/77 Accessories Approved rating data 1) For use with Pilot Duty General Use Ordering data, motor-protective circuit-breaker PKZ2/S-SP”Self-Protected Starter” → Page 7/53 AC DC Accessories Standard auxiliary contacts NHI11-PKZ2 PKZ2/ZM..., PKZ2...SP A 600, R 300 5 A – 600 V 0.5 A – 250 V NHI22-PKZ2 PKZ2/ZM..., PKZ2...SP 10 A – 300 V NHI11S-PKZ2 PKZ2/ZM-... NHI22S-PKZ2 PKZ2/ZM-... NHI2-11S-PKZ2 PKZ2/ZM-... Trip-indicating auxiliary contacts AGM2-11-PKZ2 PKZ2/ZM..., PKZ2...SP A 600, R 300 10 A – 600 V 0.5 A – 250 V 2) Short-circuit indicators K-AGM-PKZ2 PKZ2/ZM..., PKZ2...SP Shunt release A-PKZ2-... PKZ2/ZM..., PKZ2...SP 24 – 600 V 24 – 250 V U-PKZ2(...) PKZ2/ZM..., PKZ2...SP 24 – 600 V 24 – 125 V U-HI20-PKZ2(...) PKZ2/ZM..., PKZ2...SP 24 – 600 V 24 – 125 V B 600, R 300 10 A – 600 V 0.5 A – 250 V UVHI-PKZ2(...) PKZ2/ZM..., PKZ2...SP 24 – 600 V 24 – 125 V B 600, R 300 10 A – 600 V 0.5 A – 250 V Auxiliary contacts for contact module HI11-S-PKZ2 PKZ2/ZM-... A 600, R 300 10 A – 600 V 0.5 A – 250 V 2) HI20-S-PKZ2 PKZ2/ZM-... A 600 10 A – 600 V HI11-S/EZ-PKZ2 PKZ2/ZM-... A 600, R 300 5 A – 600 V 0.5 A – 250 V 2) 10 A – 300 V Remote operator RE-PKZ2 PKZ2/ZM..., PKZ2...SP 3) RS-PKZ2 PKZ2/ZM..., PKZ2...SP D 300 – R 300 1.5 A – 240 V AC0.6 A – 600 V AC Amplifier module forremote drives ETS4-VS3 PKZ2/ZM..., PKZ2...SP B 300 – R 300 5 A – 250 V AC Clip plates C-PKZ2 PKZ2/ZM-... Door coupling handles H-PKZ2 PKZ2/ZM..., PKZ2...SP RH-PKZ2 PKZ2/ZM..., PKZ2...SP Extension shaft A-H-PKZ2 PKZ2/ZM..., PKZ2...SP Base for separate mounting EZ-PKZ2 – Three-phase commoning links B3.1/3-PKZ2 PKZ2/ZM..., PKZ2...SP max. 100 A B3.1/2-PKZ2 PKZ2/ZM..., PKZ2...SP max. 85 A Connecting Terminals for three-phase commoning links BK50/3-PKZ2 PKZ2/ZM..., PKZ2...SP max. 100 ATerminal capacity AWG 14-0 Torque 4.5 Nm Padlocking feature SVB-PKZ2 PKZ2/ZM..., PKZ2...SP Mechanical interlock MV-PKZ2 – Coding pins CS-PKZ2 PKZ2/ZM..., PKZ2...SP Busbar adapters AD-... PKZ2/ZM..., PKZ2...SP Notes Terminal capacities for all PKZ2 system add-on modules:• Cables min. AWG 18, max. AWG 14• Torque 1.0 Nm 1)   Device for world markets IEC = UL/CSA. 2)   150 V same polarity. 3)  Maximum actuating voltage 120 V 60 Hz or 120 V DC.

7/78 Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breakers 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breakers Technical data PKZ2/ZM-…(8) PKZ2/ZM-…(8)/SE… PKZ2/ZM-…(8)/S(+CL) S(EA)… General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14, GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60068-2-78;cyclic to IEC 60068-2-30 Ambient temperature Storage °C -25…70 -25…70 -25…70 -25…70 Open °C -25…60 -25…60 -25…60 -25…60 Encapsulated °C -25…40 -25…40 -25…40 -25…40 Built-in position Direction of incoming supply Any Any Any Any Degree of protection IP00 IP00 IP00 IP00 Mechanical shock resistance Half-sinusoidal shock 20 ms to IEC 60068-2-27 g 30 8 8 8 Installation altitude m max. 2000 max. 2000 max. 2000 max. 2000 Terminal capacity Solid or stranded mm 2 1 x (1 - 16)2 x (1 - 6) 1 x (1 - 16)2 x (1 - 6) 1 x (1 - 16)2 x (1 - 6) 1 x (1 - 16)2 x (1 - 6) Flexible with ferrule mm 2 1 x (1.5 - 10)2 x (1.5 - 6) 1 x (1.5 - 10)2 x (1.5 - 6) 1 x (1.5 - 10)2 x (1.5 - 6) 1 x (1.5 - 10)2 x (1.5 - 6) Solid or stranded AWG 14 - 6 14 - 6 14 - 6 14 - 6 Terminal screw tightening torque Main conductors Nm 1.8 1.8 1.8 1.8 Auxiliary conductors Nm 1 1 1 1 Main contacts Rated impulse withstand voltage  U imp V AC 6000 6000 6000 6000 Overvoltage category/pollution degree III/3 III/3 III/3 III/3 Rated operational voltage U e V AC 690 690 690 690 Rated uninterrupted current = rated operational current I u  = I e A 40 40 40 40 Rated frequency Hz 50 - 60 50 - 60 50 - 60 50 - 60 Heat dissipation (3 pole at operating temperature) W 14 23 23 9 Lifespan, mechanical 1) Operations x 10 6 0.1 5 5 5 Lifespan, electrical 100 % AC-3 Operations x 10 6 0.05 1 1 1 AC-4 Operations x 10 6 – 0.03 0.03 0.03 Maximum operating frequency Operations/h Ops/h 60 → Page 7/72 Motor switching capacity AC-3 up to 690 V A 40 40 40 40 DC-5 up to 250 V A 40 40 40 40 DC applications Breaking capacity I cn I cn  (250 V DC), L/R = 15 ms kA 30 30 50 – I cn  (125 V DC), L/R = 15 ms kA 50 50 65 – Switching times in the even of a short-circuit load Minimum command time ms Approx.  2 Approx.  2 Approx.  2 – Opening delay ms Approx.  0.5 Approx.  0.5 Approx.  0.5 – Total opening delay ms 6 6 4 – ZM-…-PKZ2 ZMR-…-PKZ2 ZM-…-8-PKZ2(4) Trip blocks Function Motor protection Motor protection System protection Temperature compensation To IEC/EN 60947, VDE 0660 °C -5…40 -5…40 -5…40 Operating range °C -25…60 -25…60 -25…60 Temperature compensation residual error for T  40 °C %/K ≦ 0.25 ≦ 0.25 ≦ 0.25 Short-circuit release tolerance % ± 20 ± 20 ± 20 Setting range of overload releases x I u 0.6 - 1 0.6 - 1 0.6 - 1 Short-circuit releases x I u 8.5 - 14 8.5 - 14 5 - 8.5 Notes 1)  With dual-frequency coil 50/60 Hz the  mechanical lifespan reduces by 30% S CL S CL 90° 90°  90°  90° 90° 30°  PKZ2 PKZ2/.../S PKZ2/.../+CL PKZ2/.../S PKZ2 PKZ2/.../+CL { PKZ2 PKZ2

Motor-protective circuit-breakers PKZ2 (High-capacity) contact modules, current limiters 2010 CA08103002Z-EN www.eaton.com 7/79 (High-capacity) contact modules, current limiters High-capacity contact module S(EA)... Switching times Closing delay ms 9 - 30 Opening delay ms 4 - 12  Duty factor % DF 100 Rated making capacity at p.f. = 0.45 A 400 Rated breaking capacity at p.f. = 0.45 A 400 Magnet systems AC operation Operating range Pick-up voltage x U s 0.85 - 1.1 Drop-out voltage x U s 0.4 - 0.6 Power consumption AC pick-up rating Pick-up VA 190 AC consumption when closed Holding VA 13 DC operation Rated control voltage U s V DC 24 Operating range Pick-up voltage x U s 0.85 - 1.1 Power consumption DC pick-up rating Pick-up W 150 DC consumption when closed Holding W 2.7 Current consumption Pick-up current (16 - 22 ms) A 6.3 Holding current mA 113 Rated operational current, enclosed/open AC-1  230 V I e A 40  400 V I e A 40  440 V I e A 40  500 V I e A 40  690 V I e A 40 AC-3  230 V I e A 40  400 V I e A 40  440 V I e A 40  500 V I e A 40  690 V I e A 40 AC-4  230 V I e A 30  400 V I e A 30  440 V I e A 30  500 V I e A 28  690 V I e A 25 Current limiters CL-PKZ2 Rated making capacity at p.f. = 0.45 A 400 Rated breaking capacity at p.f. = 0.45 A 400 AC-1 operation Conventional thermal current I th A 40 SE.../...PKZ, CL-PKZ

7/80 Motor-protective circuit-breakers PKZ2 Auxiliary contacts, shunt release 2010 CA08103002Z-EN www.eaton.com Auxiliary contacts, shunt release NHI11(S)-PKZ2 NHI22(S)-PKZ2 NHI2-11S-PKZ2 AGM2-11-PKZ2 HI…-S-PKZ2 HI11-S/EZ-PKZ2 ZMR-…(95 - 96) ZMR-…(97 - 98) Auxiliary contacts Rated impulse withstand voltage  U imp V AC 6000 6000 6000 6000 6000 6000 6000 6000 Overvoltage category/degree of pollution III/3 III/3 III/3 III/3 III/3 III/3 III/3 III/3 Rated operating voltage U e V AC 500 500 500 500 500 500 500 500 Rated operational current AC-15 230 - 240 V I e A 6 6 6 5 6 6 1.5 1.5 400 - 415 V I e A 3 1.5 3 3 1.5 3 0.7 0.5  440 V I e A 1.5 1.5 1.5 1.5 1.5 1.5 0.5 0.3  500 V I e A 1.5 1.5 1.5 1.5 1.5 1.5 0.5 0.3 Lifespan, mechanical Operations x 10 6 0.1 0.1 5 0.01 5 5 0.01 0.01 Lifespan, electrical Operations x 10 6 0.05 0.05 1 0.05 1 1 0.05 0.05 Control circuit reliability (at U e  = 24 V DC,  U min  = 17 V, I  min = 10 mA) Fault probability λ Control circuit reliability through the entire mechanical lifespan Positive opening contacts as specified in EN60947-5-1 Appendix L – – Yes Yes – – – – Short-circuit strength without welding Fuseless 240 V: PKZM0-6.3415 V: PKZM0-4500 V: PKZM0-1.6 – – Fuse A gG/gL 10 10 10 6 10 10 10 10 Terminal capacity Solid or flexible with ferrule mm 2 1 x (0.75 - 2.5)2 x (0.75 - 2.5) Solid or stranded AWG 1 x (22 - 14)2 x (22 - 14) 22 - 14 Safe isolation according to EN 61140 Between auxiliary contacts and main contacts V AC 690 690 500 – 500 500 – – U-PKZ2… U-HI20-PKZ2… UVHI-PKZ2 Undervoltage release Rated impulse withstand voltage  U imp V AC 6000 6000 6000 Overvoltage category/pollution degree III/3 III/3 III/3 Terminal capacity Solid or flexible conductor with ferrule mm 2 1 x (0.75 - 2.5)2 x (0.75 - 2.5) 1 x (0.75 - 2.5)2 x (0.75 - 2.5) 1 x (0.75 - 2.5)2 x (0.75 - 2.5) Solid or stranded AWG 22 - 14 22 - 14 22 - 14 Rated operating voltage U e V AC 24 - 600 24 - 600 24 - 600 Rated operating voltage U e V DC 24 - 125 24 - 125 24 - 125 Drop-out voltage x U s 0.7 - 0.35 0.7 - 0.35 0.7 - 0.35 Power consumption AC voltage AC pick-up rating Pick-up VA 5 5 5 AC consumption when closed Holding VA 3 3 3 DC voltage DC pick-up rating Pick-up W 3 3 3 DC consumption when closed Holding W 3 3 3 OFF delay ms – – 200 Rated operating current AC-15  230 V I e A – 6 6  400 V I e A – 3 3  440 V I e A – 1.5 1.5 NHI...PKZ, U-PKZ2

Motor-protective circuit-breakers PKZ2 Remote operators 2010 CA08103002Z-EN www.eaton.com 7/81 Remote operators A-PKZ2… Shunt release (for power circuit-breakers) Rated impulse withstand voltage  U imp V AC 6000 Overvoltage category/pollution degree III/3 Terminal capacity Solid or flexible conductor with ferrule mm 2 1 x (0.75 - 2.5)2 x (0.75 - 2.5) Solid or stranded AWG 22 - 14 Rated operating voltage U e V AC 24  - 600 Rated operating voltage U e V DC 24 - 250 Operating range AC voltage x U s 0.7 - 1.1 DC voltage x U s 0.7 - 1.1 Power consumption AC voltage AC pick-up rating Pick-up VA 5 AC consumption when closed Holding VA 3 DC voltage DC pick-up rating Pick-up W 3 DC consumption when closed Holding W 0.3 RE-PKZ2 RS-PKZ2 Remote drives Rated impulse withstand voltage  U imp V AC 6000 6000 Overvoltage category/pollution degree III/3 III/3 Rated operating voltage U e V AC 380 - 440 380 - 440 Rated operating voltage U e V AC/DC 24 - 240 24 - 240 Safe isolation to VDE 0106 Part 101 and Part 101 A1 between the auxiliary contacts and main circuits V AC 500 500 Required short-time rating (30 ms) VA/W 700 700 Control transformer short-time rating VA 1000 1000 Short-circuit voltage % 4.4 4.4 Closing delay ms ≦ 30 ≦ 30 Opening delay ms ≦ 30 ≦ 30 Reset time to OFF ms ≦ 30 ≦ 30 Maximum operating frequency Max. operating frequency Ops/h 60 60 Operating range AC voltage x U s 0.85 - 1.1 0.85 - 1.1 DC voltage x U s 0.85 - 1 0.85 - 1 Lifespan, electrical Operations x 10 6 0.05 0.05 Integrated auxiliary contact (signal manual/automatic 33/34) Thermal rated operational current I th A 1.5 1.5 Rated operational current AC-14 230/240  V I e A 1.5 1.5 400/415 V I e A 1 1  440 V I e A 0.5 0.5 Terminal capacity Solid or flexible conductor with ferrule mm 2 1 x (0.75 - 2.5)2 x (0.75 - 2.5) 1 x (0.75 - 2.5)2 x (0.75 - 2.5) Solid or stranded AWG 22 - 14 22 - 14 BK…-PKZ2, B3.1/…-PKZ2 Supply terminal and three-phase commoning link Rated impulse withstand voltage  U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated operating voltage U e V AC 690 Rated uninterrupted current  I u A 120 RE-PKZ, RS-PKZ

7/82 Motor-protective circuit-breakers PKZ2 Motor-protective circuit-breaker 2010 CA08103002Z-EN www.eaton.com Motor-protective circuit-breaker Motor-protective circuit-breakers and trip blocks Circuit-breakers PKZ2/ZM… + ZMR-…-PKZ2 PKZ24 High-capacity compact starters Standard auxiliary contacts for (high-capacity) compact starter PKZ2/ZM-…/S NHI…S-PKZ2 PKZ2/ZM-.../SE1A... Standard auxiliary contacts Shunt release (for power circuit-breakers) Remote drives Undervoltage release NHI…-PKZ2 U-PKZ2… RE-PKZ2… A-PKZ2… RS-PKZ2… Contact modules Base for separate mounting Trip-indicating auxiliary contacts High-capacity contact modules Auxiliary contact for separate mounting AGM2-11-PKZ2 Current limiters SE1A/11-PKZ2(...) EZ-PKZ2 S-PKZ2(...) HI11-S/EZ-PKZ2 CL-PKZ2 6 0 + M4 105 19 ZMR 19 62.571.5 83 44.5 109 133.5 62 45 68 15    6 81.5 19 28.5 67 105 44.5 109 68 45 118 133.5 8.5 6 6.1 11 38 62.5 27 19 71.5 M4 I 0 + 125 190 46.4 111.4 135.9 25 15 109 168 204 11 83 18.5 S-G (Varistor) S-G (Varistor) 18 18 18 NHI 22S NHI 2-11S 190 44 77 153 NHI 11S 18 18 NHI 22 NHI 11 105 68 44 77 18 44 109113 105 105 45 109122126 36 85 103.5 44 109 27 1938 62.5 10 25 Type -G only Typ -G only 77 37 53 125 38 19 M 4 65.5 3 11 100 40.8 18 31.5 45 AGM PKZ2

Motor-protective circuit-breakers PKZ2 Accessories 2010 CA08103002Z-EN www.eaton.com 7/83 Accessories Insulated enclosures for surface mounting CI19EA-PKZ2 CI19EB-PKZ2CI19ED-PKZ24 Drilling dimensions CI23EA-PKZ22 CI23EB-PKZ22 Drilling dimensions Insulated enclosure for flush mounting Door coupling handles E-PKZ2 PKZ2-X… E54-PKZ2 ① At least 100 mm from cover hinge Three-phase commoning links Extension terminal Shroud for unused terminals B3.1/3-PKZ2 B3.1/2-PKZ2 BK50/3-PKZ2 H-B3-PKZ2 Mechanical interlock with (high-capacity) contact module Neutral terminal for (high-capacity) contact module MV-PKZ2 N-PKZ2 200 130.5 46 99.5 150 12.5 12.5 175 125 M4 12.5 12.5 150 150 200 175 125 99.5 130.5 250 187.5 46 162 225 12.5 12.5 M4 162 225 12.5 12.5 187.5 150 250 M4 7 E-PKZ 2 171 123 130 111 62 17 E 54-PKZ 2 93 104 70 155 155 93 91 Mounting aperturefor 2 – 50 mmpanel thickness Mounting aperturefor 1.5 – 16 mmpanel thickness max. 6 mm (R) H-PKZ 2 with serial no. 01 54 20 64 64 48 48 7.5 a 222 33 60 140 33 60 4.5 4.2 75 18 84.5 78.5 50 25 1.5 14.6 10 10 149 21 15 59 56.5 36 128.5 4.5 85 103.5 44 109 19 PKZ2: E-PKZ, B3...-PKZ, MV-PKZ

2010 CA08103002Z-EN www.eaton.com 7/84 DC string circuit-breakers, DC switch-disconnectors Description a b d e f c Photovoltaics description Photovoltaic systems convert sunlight directly into electrical energy using solar cells. Photovoltaics represent a renewable source of energy that can be used on private and public buildings, as well as in large-scale power stations.These systems can be independent from the power grid or can be connected to it. Photovoltaic systems that are connected to the grid feed the generated power directly into the mains network. This eliminates the need for temporary storage. These systems consist of solar cells, one or more inverters, and a protective device for automatic cutoff in the event of a grid fault. Because of this, photovoltaic systems that are connected to the grid require extremely reliable and safe individual components. ① DC string circuit-breaker  PKZ-SOL ② DC switch-disconnector  P-SOL ③ Ready-to-install DC switch- disconnector SOL ④ Inverter module⑤ AC main switch⑥ Network Features DC string circuit-breakers • Protect PV modules from fault  currents, prevent (in larger systems, for instance) intact modules from feeding power back into a module with a short-circuit.  • Are ready for operation immediately  after tripping and after the trip cause has been fixed. • Open and for installation in  customized generator terminal boxes.  • Tripping currents are adjustable  within a wide range of limits. • Optional shunt releases A-PKZ0 and  undervoltage releases U-PKZ0 enable remote shutdown, e.g for the fire department. Optional auxiliary contact NHI-E-PKZ0 signals switching state. • When installed in an enclosure,  suitable for voltages of up to 900 VDC.  DC switch-disconnectors • Required, according to standard  VDE 0100-712 (June 2006), between the PV module and inverter. • Enclosed and open (for installation  in enclosure) switch-disconnectors for voltages of up to 1,000 VDC.  • Usable as a separate switching  point as required in VDI Guideline VDI 6012, e.g. by de-energizing an inverter in a completely safe manner. • Two-pole switching, making it  suitable for non-earthed systems as well. • TÜV-certified.• Open switch-disconnectors P-SOL  are designed for installation in customer-specific enclosures or inverters.  • Mounting on 35 mm top-hat rails,  their terminals enable a connection to all popular cable types.  • Separate rotary handles and shaft  extensions allow for flexible installation.  • An auxiliary switching block can be  mounted in order to provide switching state feedback.  • A shunt release or undervoltage  release is available for remote tripping. • Switch-disconnectors SOL with  enclosure are ready for installation. Models for 2 and 4 or 4 and 8 strings and for the most popular connector types, such as MC3, MC4, and metric screw connectors, allow for easy integration into various system concepts. • Enclosure provides degree of  protection IP65, making outdoor mounting possible.  • Lockable mechanism provides safety  when maintenance is required.  • Pressure-equalizing element  prevents the formation of condensed water, preventing failures caused by voltage sparkovers. P-SOL, PKZ-SOL, SOL

DC string circuit-breakers, DC switch-disconnectors DC switch-disconnectors, ready to install 2010 CA08103002Z-EN www.eaton.com 7/85 DC switch-disconnectors, ready to install Ordering Inputs Outputs Max. rated operational current DC-21A Part no.Article no. PriceSee price list Std. pack Number of strings Connection type Number of strings Connection type I e A DC switch-disconnector, ready-to-install Rated operational voltage U e  1000 V Degree of protection IP65Protection class 22 pole 2 MC3 1 MC3 20 SOL20/2MC3120913 1 off 4 MC3 1 MC3 20 SOL20/4MC3120914 1 off 2 MC4 1 MC4 20 SOL20/2MC4120915 1 off 4 MC4 1 MC4 20 SOL20/4MC4120916 1 off 2 Screw connector M12 1 Screw connector M16 20 SOL20/2MV120919 1 off 2 MC3 1 MC3 30 SOL30/2MC3120920 1 off 4 MC3 1 MC3 30 SOL30/4MC3120921 1 off 2 MC4 1 MC4 30 SOL30/2MC4120922 1 off 4 MC4 1 MC4 30 SOL30/4MC4120923 1 off 2 Screw connector M12 1 Screw connector M16 30 SOL30/2MV120926 1 off 4 MC3 1 Screw connector M20 63 SOL60/4MC3120927 1 off 8 MC3 1 Screw connector M20 63 SOL60/8MC3120928 1 off 4 MC4 1 Screw connector M20 63 SOL60/4MC4120929 1 off 8 MC4 1 Screw connector M20 63 SOL60/8MC4120930 1 off 4 Screw connector M12 1 Screw connector M20 63 SOL60/4MV120933 1 off Information relevant for export to North America NA Certification Request filed for UL and CSA SOL HPL07085EN

7/86 DC string circuit-breakers, DC switch-disconnectors 2010 CA08103002Z-EN www.eaton.com Max. rated operational currentDC-21A Permissible solar module short-circuit currents Part no.Article no. PriceSee price list Std. pack I e A DC switch-disconnector, open Rated operating voltage U e  1000 V Protection class II2 pole 20 P-SOL20120934 1 off 30 P-SOL30120935 63 P-SOL60120936 DC string circuit-breakers Rated operating voltage U e  900 V Protection class II2 pole 12 5  -  9 PKZ-SOL12120937 1 off 20 9  -  15 PKZ-SOL20120938 30 15  -  22 PKZ-SOL30120939 40 22  -  30 PKZ-SOL40 1) 120940 50 29  -  38 PKZ-SOL50 1) 120941 60 38  -  47 PKZ-SOL60 1) 120942 Notes 1)  Availability from November 2010 Information relevant for export to North America NA Certification Request filed for UL and CSA 1 2 3 1 2 3 Accessories Page 2 Auxiliary contacts NHI-E → 7/10 3 Shunt releases A-PKZ0 → 7/29 3 Undervoltage releases U-PKZ0 → 7/29 P-SOL, PKZ-SOL HPL07086EN

DC string circuit-breakers, DC switch-disconnectors 2010 CA08103002Z-EN www.eaton.com 7/87 Engineering P-SOL and PKZ-SOL wiring Switch-disconnector P-SOL String circuit-breaker PKZ-SOL Non-earthed grid Earthed grid Non-earthed grid Earthed grid SOL internal circuit SOL20/2MC3SOL20/2MC4SOL30/2MC3SOL30/2MC4 SOL20/2MVSOL30/2MV SOL20/4MC3SOL20/4MC4SOL30/4MC3SOL30/4MC4 SOL60/4MC3SOL60/4MC4 SOL60/4MV SOL60/8MC3SOL60/8MC4 1000 VDC 1 3 5 2 4 6 1000 VDC 1 3 5 2 4 6 900 VDC 1 3 5 2 4 6 900 VDC 1 3 5 2 4 6 - Strings + Strings Output Input + - 1 3 5 2 4 6 - Strings + Strings Output (M16) Input (M12) + - 1 3 5 2 4 6 - Strings + Strings Output Input + - 1 3 5 2 4 6 - Strings + Strings Output (M20) Input + - 1 + - 3 5 2 4 6 - Strings  + Strings Input (M12) Output (M20) + - + - 1 3 5 2 4 6 - Strings + Strings Input Output (M20) + - + - 1 3 5 2 4 6 P-SOL, PKZ-SOL, SOL

7/88 DC string circuit-breakers, DC switch-disconnectors Characteristic curves 2010 CA08103002Z-EN www.eaton.com Characteristic curves Characteristic curve set value - short-circuit current As specified in the IEC 62548-1 draft for the protection of photovoltaic modules, the tripping current of the circuit- breaker must lie between 1.4 and 2 times the value of the photovoltaic module‘s short-circuit current.Since only the current values of the installed overload release can be plotted on the setting scale for the  circuit-breaker 1) , the correlation  between the protective device‘s tripping current and the photovoltaic module‘s short-circuit current must be specified for each point of the scale in a suitable form. 1)  Standard IEC/EN 60947-2 (Section  4.7.3) prohibits directly specifying the photovoltaic short-circuit current on the circuit-breaker's setting scale, meaning that only the current set value of the operating current can be plotted there. Tripping characteristics Tripping characteristicsDC string circuit-breaker PKZ-SOL 10 1 0.001 0.01 0.1 10.000 1.000 100 10 1 100 x  I r 1 h 2 h (1 min) t [s] Setting aid for string circuit-breaker PKZ-SOL Se t val u e on  ci rc u it- br ea ke r [A] Short-circuit current in solar module [A] 0 5 10 15 20 25 30 35 40 50 0 10 20 30 40 50 60 70 45 PKZ-SOL60 PKZ-SOL50 PKZ-SOL40 PKZ-SOL30 PKZ-SOL20 PKZ-SOL12 PKZ-SOL7 PKZ-SOL4 I r [A] I SC...

DC string circuit-breakers, DC switch-disconnectors DC switch-disconnectors 2010 CA08103002Z-EN www.eaton.com 7/89 Technical data DC switch-disconnectors SOL20 SOL30 SOL60 Rated operational current Ie at DC-21A A 20 30 63 Number of poles 2 2 2 Rated operational voltage U e V DC 1000 1000 1000 Isolating characteristics Yes Yes Yes Standards IEC/EN 60 947-3UL 508, TÜV certificate Lifespan mechanical Operations 100,000 100,000 30,000 Lifespan electrical Operations 100,000 100,000 30,000 Max. operating frequency, mechanical Ops/h 120 120 120 Climatic proofing Damp heat, constant, to IEC 60 068-2-78Damp heat, cyclic, to IEC 60 068-2-30 Ambient temperature  min./max. °C -25 ... +60 -25 ... +60 -25 ... +60 Mounting position Any Any Any Degree of protection IP 65 65 65 Dimensions Width  mm 100 100 160 Height  mm 215 215 305 Depth  mm 130 130 210 Weight kg 0.42 0.42 2.2 Lockable in OFF position Yes Yes Yes Rated short-time withstand current  , 1 s to EN 60947-3 I cw kA 0.24 0.36 0.72 Rated short-circuit making capacity to EN 60947-3 I cm kA 0.32 0.32 0.6 Internal resistance mΩ 8 7 4 P-SOL20 P-SOL30 P-SOL60 Rated operational current at DC-21A I e A 20 30 63 Number of poles 2 2 2 Rated operational voltage U e V DC 1000 1000 1000 Isolating characteristics Yes Yes Yes Standards IEC/EN 60 947-3UL 508, TÜV certificate Lifespan mechanical Operations 100,000 100,000 30,000 Lifespan electrical Operations 100,000 100,000 30,000 Max. operating frequency, mechanical Ops/h 120 120 120 Climatic proofing Damp heat, constant, to IEC 60 068-2-78Damp heat, cyclic, to IEC 60 068-2-30 Ambient temperature  Open min./max. °C -25 ... +60 -25 ... +60 -25 ... +60 Mounting position Any Any Any Dimensions Width  mm 58 58 55 Height  mm 93 93 140 Depth  mm 76 76 160 Mounting Top-hat rail 35 mm 35 mm 35 mm Screw mounting – – 2 x M4 x 1830 x 130 Weight kg 0.32 0.32 1.25 Terminals Flexible with ferrule mm 2 1 x (1-6) 1 x (1-6) 1 x (1-35) mm 2 2 x (1-6) 2 x (1-6) 2 x (1-35) solid/stranded AWG 18 - 14 18 - 14 14 - 2 Rated short-time withstand current  , 1 s to EN 60947-3 I cw kA 0.24 0.36 0.72 Rated short-circuit making capacity to EN 60947-3 I cm kA 0.32 0.32 0.6 Internal resistance mΩ 6 5 3 P-SOL, SOL

7/90 DC string circuit-breakers, DC switch-disconnectors DC string circuit-breakers, open 2010 CA08103002Z-EN www.eaton.com DC string circuit-breakers, open PKZ-SOL12 PKZ-SOL20 PKZ-SOL30 PKZ-SOL40 PKZ-SOL50 PKZ-SOL60 Rated operational current at DC-21A/750VDC I e A 12 20 30 40 50 63 Number of poles 2 2 2 2 2 2 Rated operational voltage U e V DC 900 900 900 900 900 900 Thermal tripping 1.05 ...1.3 x I e Electromagnetic tripping 6 x I e Standards IEC/EN 60 947-2UL 508, TÜV certificate Climatic proofing Damp heat, constant, to IEC 60 068-2-78Damp heat, cyclic, to IEC 60 068-2-30 Ambient temperature  Open min./max. °C -25 ... +60 -25 ... +60 -25 ... +60 -25 ... +60 -25 ... +60 -25 ... +60 Mounting position PKZ-SOL12to PKZ-SOL60 PKZ-SOL12to PKZ-SOL30 Dimensions Width  mm 58 58 58 55 55 55 Height  mm 93 93 93 140 140 140 Depth  mm 76 76 76 160 160 160 Mounting Top-hat rail 35 mm 35 mm 35 mm 35 mm 35 mm 35 mm Screw mounting – – – 2 x M4 x 1830 x 130 2 x M4 x 1830 x 130 2 x M4 x 1830 x 130 Weight kg 0.32 0.32 0.32 1.25 1.25 1.25 Terminals   flexible with ferrule mm 2 1 x (1-6) 1 x (1-6) 1 x (1-6) 1 x (1-35) 1 x (1-35) 1 x (1-35) mm 2 2 x (1-6) 2 x (1-6) 2 x (1-6) 2 x (1-35) 2 x (1-35) 2 x (1-35) solid/stranded AWG 18 - 14 18 - 14 18 - 14 14 - 2 14 - 2 14 - 2 Internal resistance mΩ 31 12 7 – – – 90° 90° 90° PKZ-SOL

DC switch-disconnectors, DC string circuit-breakers DC string circuit-breakers, open 2010 CA08103002Z-EN www.eaton.com 7/91 Dimensions P-SOL20 P-SOL60 P-SOL30 PKZ-SOL40 PKZ-SOL12 PKZ-SOL50 PKZ-SOL20 PKZ-SOL60 PKZ-SOL30 SOL20 SOL60 SOL30 58 45 92.5 43.5 62 70 5.5 30 7.5 118 127 145 160 55 130 140 125 65 45 53 4 NHI-E... NHI-E... 100 180.3 b 130.5 160 246 b 215 Connection type b  mm MC3 195 MC4 234 MV 224 Connection type b  mm MC3 275 MC4 314 MV 304 P-SOL, PKZ-SOL, SOL