Eaton Denizcilik Power Xpert 9395 Marine UPS veri merkezi katalogu
Power Xpert 9395 Marine UPS 225 - 1100 kVA Data sheet Power Xpert 9395 Marine UPS 225-1100 kVA Advanced power protection for:• Navigation systems• Emergency lightning• Computer systems• General Services Double conversion UPS Qualified design for marine and offshore environment • Compact design for saving space• Easy to install, mounting rails can be bolted or welded to the deck/bulk head • IP22 protection class• Vibration absorbers under and at the back of the cabinet• Maintenance from the front Premium power performance • Double conversion provides the highest level of protection available by isolating the output power from all input anomalies. • Active power factor correction (PFC) provides 0,99 input power factor and less than 3-5% ITHD, thus eliminating interference with other critical equipment in the same network and enhancing compatibility with generators. • The UPS is optimized for protecting modern 0,9 p.f. rated IT equipment without the need to oversize. True reliability • Patented Powerware HotSync® technology makes possible to parallel up to five UPSs to increase availability or add capacity. The technology enables load sharing without any communication line, thus eliminating single point of failure. • The multi-module 9395 can be configured with inherent redundancy – anytime the load is below 50%, the system becomes automatically redundant. • ABM® technology charges batteries only when necessary, preventing batteries corrosion and prolonging batteries service life by up to 50%. • Internal automatic static bypass switch. Extensive configurability • Can be used as a frequency converter (50 Ô 60Hz and 60 Ô 50Hz) e.g. in shore power applications. • The 9395 is a completely integrated system than incorporates multiple power modules and system switchgear on factory pre-wired bases. • A multilingual graphical LCD display makes possible to monitor the UPS status easily. • Wide software and connectivity options provide monitoring, management and shutdown capabilities over network. Cost savings and sustainability • Up to 99% efficiency with Energy Saver System (ESS) and Variable Module Management (VMMS) technologies enables to reduce energy cost, extend battery run times and ensure cooler operating conditions. • The new design requires 50-80% less energy in manufacturing due to less energy required for testing and to the smaller configuration. • Pre-wired configuration enables to reduce cabling busbar costs and installation time. Front accessible design minimizes installation costs and saves valuable data centre space. • With Easy Capacity Test feature the 9395 can test its entire power train under full load stress without the requirement of an external load. • A single technical platform used in Eaton´s three-phase UPS products guarantee easy upgrades and similarity in service, thus lowering total cost of ownership. ™ Due to outstanding green performance, the Power Xpert 9395 has earned the “An Eaton Green Solution”™ label
Power Xpert 9395 Marine UPS 225 - 1100 kVA © 2013 Eaton Corporation, All Rights Reserved, 00DATA1018142 rev C, January 2013 TEChniCAl SPECifiCATionS UPS output power rating (0,9 p.f.) kVA 225 275 450 550 675 825 900 1100 kW 204 250 408 500 612 750 816 1000 General Efficiency in double conversion mode (full load) 94% (without transformer) Efficiency in double conversion mode (half load) 93% (without transformer) VMMS (double conversion) significantly increased efficiency at low loads Efficiency in Energy Saver System (ESS) up to 99% Distributed parallelling with Hot Sync technology 5 + 1 Field upgradeable yes Inverter/rectifier topology transformer-free IGBT with PWM Audible noise 76 dB; 81 dB (825 and 1100 kVA) Colour RAL 7035 Input Nominal voltage rating (configurable) 220/380, 230/400, 240/415 V 50/60 Hz With external transformer e.g. 230, 440, 480, 690 V Input voltage range +15% / -15%, +10% / -10% for bypass Input frequency range 45-65 Hz Input power factor 0,99 Input ITHD 3-5% on nominal load, depending on the utility UTHD Soft start capability Yes Internal backfeed protection Yes Output Nominal voltage rating (configurable) 220/380, 230/400, 240/415 V 50/60 Hz With external transformer e.g. 230, 440, 480, 690 V Output UTHD 3% (100% linear load); 5% (reference non linear load) Output power factor 0,9 (e.g. 250 kW at 275 kVA) Permitted load power factor 0,7 lagging - 0,8 leading Overload on inverter 10 min 100-110%; 30 sec 110-125%; 10 sec 125-150%; 300 ms 150% Overload when bypass avail- able Continuous 115%, 20 ms 1000% Note! Bypass fuses may limit the overload capability Battery Type VRLA, AGM, Gel, Wet Cell (NiCd batteries on request) Charging method ABM technology or Float Temperature compensation Optional Battery nominal voltage (lead-acid) 480 V (40 x 12 V, 240 cells) Charging current / ModelDefault AMax A 2753883 55076166 825114249 1100152332 Limited by maximum UPS input current rating Dimensions and weights 225 kVA, 275 kVA 1364 x 1152 x 2158 mm (wxdxh) 1000 kg 225 kVA redundant, 275 kVA redundant 1904 x 1152 x 2158 mm 1600 kg 450, 500, 550 kVA 1904 x 1152 x 2158 mm 1600 kg 450, 550 kVA redundant 2644 x 1152 x 2158 mm 2400 kg 675, 825 kVA 3724 x 1152 x 2158 mm 2920 kg 675, 825 kVA + 1 redundant 4464 x 1152 x 2158 mm 3570 kg 1100 kVA 4464 x 1152 x 2158 mm 3570 kg Accessories External battery cabinets with long-life batteries, NiCd batteries on request, X-Slot connectivity (Web/SNMP, ModBus/Jbus, Relay, Hot Sync, ViewUPS-X remote display), integrated manual bypass for 225-550 kVA Communications X-Slot 4 communication bays Serial ports 1 available Relay inputs/outputs 5/1 programmable Compliance with standards Classification survey report On request In the interests of continuous product improvement all specifications are subject to change without notice. www.eaton.eu/marine Front view Front view Side view 21 58 1364 1904 21 58 21 58 1152 Depending on the actual load and room ventilation, the height of the unit roof may change. 11 8 11 8