Pluto B46 v2 Programmable safety controller

Pluto B46 v2 Programmable safety controller

Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager. Safety PLC with Pluto safety bus. Totally 46 I/O: 24 failsafe inputs + 16 non-failsafe outputs/failsafe inputs + 4 individually failsafe relay outputs + 2 individually failsafe transistor outputs.

Ürün kimlikleri

SKU: 2TLA020070R1700
EAN: 7320500410615
GTIN: 7320500410615
MPN: Pluto B46 v2

Kategoriler

Özellikler

Depth
120 mm
Model
Compact
Width
90 mm
Height
84 mm
EFI00008
-
EFI00040
-
EFI00049
-
Redundancy
evet
Memory size
128 kByte
With display
evet
IO link master
hayır
Type of memory
FLASH
System accessory
hayır
Supply voltage DC
24 - 24 V
Radio standard GSM
hayır
Radio standard GPRS
hayır
Radio standard UMTS
hayır
Rack-assembly possible
hayır
With optical interface
hayır
Front built-in possible
hayır
Number of relay outputs
4
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Number of digital inputs
40
Radio standard Bluetooth
hayır
Long-Term Evolution (LTE)
hayır
Number of analogue inputs
3
Number of digital outputs
22
Number of analogue outputs
Radio standard WLAN 802.11
hayır
SIL according to IEC 61508
3
Suitable for rail mounting
evet
Number of HW-interfaces USB
Supporting protocol for ASI
hayır
Supporting protocol for CAN
evet
Supporting protocol for KNX
hayır
Supporting protocol for LON
hayır
Max. number of time switches
256
Supporting protocol for DNP3
hayır
Number of HW-interfaces other
1
Number of interfaces PROFINET
Suitable for safety functions
evet
Voltage type (supply voltage)
DC
Wall mounting/direct mounting
hayır
Number of HW-interfaces RS-232
1
Number of HW-interfaces RS-422
Number of HW-interfaces RS-485
Supporting protocol for Modbus
hayır
Supporting protocol for SERCOS
hayır
Supporting protocol for TCP/IP
hayır
Supporting protocol for SUCONET
hayır
Number of HW-interfaces parallel
Number of HW-interfaces wireless
Supporting protocol for EtherCAT
hayır
Supporting protocol for INTERBUS
hayır
Supporting protocol for PROFIBUS
evet
Appendant operation agent (Ex ia)
hayır
Appendant operation agent (Ex ib)
hayır
Explosion safety category for gas
None
Supporting protocol for DeviceNet
hayır
Supporting protocol for IEC 60870
hayır
Supporting protocol for PROFIsafe
hayır
Additional program memory possible
hayır
Explosion safety category for dust
None
Supporting protocol for EtherNet/IP
hayır
Supporting protocol for PROFINET IO
hayır
Supporting protocol for SafetyBUS p
hayır
Supporting protocol for Data-Highway
hayır
Supporting protocol for PROFINET CBA
hayır
Processing time (1K, binary operation)
1 ms
Supporting protocol for INTERBUS-Safety
hayır
Supporting protocol for DeviceNet Safety
hayır
Supporting protocol for other bus systems
evet
Supporting protocol for IEC 61850 Ethernet
hayır
Certified for UL hazardous location class I
hayır
Number of HW-interfaces industrial Ethernet
Supporting protocol for Foundation Fieldbus
hayır
Certified for UL hazardous location class II
hayır
Certified for UL hazardous location class III
hayır
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
hayır
Certified for UL hazardous location division 2
hayır
Supporting protocol for AS-Interface Safety at Work
hayır
Certified for UL hazardous location group D (propane)
hayır
Certified for UL hazardous location group B (hydrogen)
hayır
Certified for UL hazardous location group C (ethylene)
hayır
Certified for UL hazardous location group A (acetylene)
hayır
Certified for UL hazardous location group E (metal dusts)
hayır
Certified for UL hazardous location group F (carbonaceous dusts)
hayır
Certified for UL hazardous location group G (non-conductive dusts)
hayır

Videolar