Teknik Veriler
Ana Özellikler
Mounting method
On basic element
Lightning impulse current (10/350 µs)
50 kA
Number of poles
-
Construction size
-
Voltage protection level
1.5 kV
Remote signalling
-
Follow current extinguishing capability
100 kA
Max. continuous voltage AC
264 V
Nominal voltage AC
230 V
Nominal voltage DC
-
Test class
Type 1 + 2
Voltage protection level L-N
-
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
-
Max. PV-voltage
-
Voltage protection level N-PE
-
Integrated backup fuse
-
Max. conductor cross section solid (solid, stranded)
-
Max. conductor cross section flexible (fine-strand)
-
Voltage protection level (DC+ - DC-)
-
Voltage protection level (DC+/DC- - PE)
-
Specific energy (W/R)
625 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment
evet
System configuration DC
-
System configuration IT
-
System configuration TN
-
System configuration TN-C
-
System configuration TN-S
evet
System configuration TT
evet
System configuration other
-
System configuration TN-C-S
-
Voltage protection level L-PE
-
Max. overcurrent protection device, parallel connection (fuse)
-
Max. overcurrent protection device, series connection (fuse)
-
Voltage switching spark gap technology
-
Overcurrent protected voltage tapping
-
İndirilenler

N-PE spark-gap-based protection module Type 1 + Type 2 for DEHNventil M
Ürün detayları
SKU Kodu: 951050
EAN Kodu: 4013364108073
Minimum sipariş: 1
Teknik Veriler
Ana Özellikler
Mounting method
On basic element
Lightning impulse current (10/350 µs)
50 kA
Number of poles
-
Construction size
-
Voltage protection level
1.5 kV
Remote signalling
-
Follow current extinguishing capability
100 kA
Max. continuous voltage AC
264 V
Nominal voltage AC
230 V
Nominal voltage DC
-
Test class
Type 1 + 2
Voltage protection level L-N
-
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
-
Max. PV-voltage
-
Voltage protection level N-PE
-
Integrated backup fuse
-
Max. conductor cross section solid (solid, stranded)
-
Max. conductor cross section flexible (fine-strand)
-
Voltage protection level (DC+ - DC-)
-
Voltage protection level (DC+/DC- - PE)
-
Specific energy (W/R)
625 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment
evet
System configuration DC
-
System configuration IT
-
System configuration TN
-
System configuration TN-C
-
System configuration TN-S
evet
System configuration TT
evet
System configuration other
-
System configuration TN-C-S
-
Voltage protection level L-PE
-
Max. overcurrent protection device, parallel connection (fuse)
-
Max. overcurrent protection device, series connection (fuse)
-
Voltage switching spark gap technology
-
Overcurrent protected voltage tapping
-
İndirilenler