Installation bus systems
Toplam sonuç 860
- Alaka düzeyi
- Stok durumu
2CDG110207R0011
SUG/U1.1 Split Unit Gateway, FM
The Split Unit Gateway forms the interface between the KNX system and many manufacturers’ air conditioners, so-called...
2CDG110202R0011
AA/S4.1.2 Analogue Actuator, 4-fold, MDRC
The Analogue Actuator converts KNX telegrams in voltage (0...10V) or current (0…24mA) signals. These analogue output...
2CDG110203R0011
AA/A2.1.2 Analogue Actuator, 2-fold, SM
The Analogue Actuator converts KNX telegrams in voltage (0…10V) signals. These analogue output signals are used to...
2CDG120050R0011
TSA/K24.2 Thermoelectric Valve Drive, 24 V
The Thermoelectric Valve Drives TSA/K are suited for opening and closing valves in Heating, Ventilating and...
2CDG120049R0011
TSA/K230.2 Thermoelectric Valve Drive, 230 V
The Thermoelectric Valve Drives TSA/K are suited for opening and closing valves in Heating, Ventilating and...
2CDG510010R0011
FCA-M-2.3.1 Fan Coil Actuator, PWM, MDRC
For controlling blower convectors. Supports 2-pipe and 4-pipe system for heating and cooling. The fan speed levels can...
2CDG510007R0011
SA-M-8.8.1 Switch Actuator I/O, 8-fold, 6 A, MDRC
Combination device with 8 binary inputs and 8 switch actuators. Conventional push-buttons or auxiliary contacts can be...
2CDG110199R0011
DG/S2.64.1.1 DALI Gateway, Basic, 2-fold, MDRC
Single-Master DALI Controller certificated acc. to DALI-2 (EN 62386). The device is used to control DALI or DALI-2...
2CDG110198R0011
DG/S1.64.1.1 DALI Gateway, Basic, 1-fold, MDRC
Single-Master DALI Controller certificated acc. to DALI-2 (EN 62386). The device is used to control DALI or DALI-2...
2CDG510003R0011
BI-F-4.0.1 Binary Input, 4-fold, FM
4 channels can be connected with conventional push-buttons or auxiliary contacts. The information of contact scanning...
2CDG510001R0011
PS-M-64.1.1 Power Supply, 640 mA, MDRC
Free@home power supply generate and monitor the system voltage (SELV). The bus line is decoupled from the power supply...
2CDG510008R0011
HA-M-0.6.1 Heating Actuator, 6-fold, 230 V, MDRC
For controlling thermoelectric actuating drives in heating/cooling systems. The outputs are protected against...
2CDG510009R0011
HA-M-0.12.1 Heating Actuator, 12-fold, 230 V, MDRC
For controlling thermoelectric actuating drives in heating/cooling systems. The outputs are protected against...
2CDG510004R0011
BI-M-4.0.1 Binary Input, 4-fold, 230 V, MDRC
The device detects AC/DC signals of 10 - 230 V via 4 channels. The information of the signal evaluation can be used...
2CDG110192R0011
ABA/S1.2.1 Logic Controller, MDRC
Provides extensive logic functions. The logic editor is integrated into the ETS. Up to 3000 logic gates are possible....
2CDG110191R0011
WS/S4.1.1.2 Weather Station, 4-fold, MDRC
The weather station is used to detect and process 4 independent input signals acc. DIN IEC 60381 (0-1 V, 0-5 V, 0-10...
2CDG110190R0011
AE/S4.1.1.3 Analogue Input, 4-fold, MDRC
The analogue input is used to detect and process 4 independent input signals. E.g. 0-1 V, 0-5 V, 0-10 V, 0-20 mA, 4-20...
2CDG110184R0011
WZ/S1.3.1.2 Weather Unit, MDRC
The weather unit WZ/S is used to detect and process weather data from the weather sensor. The weather sensor is...
2CDG110183R0011
SA/S12.6.2.1 Switch Actuator, 12-fold, 6 A, Manual Operation, MDRC
Uses potential free contacts to switch 12 independent electrical loads via the ABB i-bus®. Manual operation and...
2CDG110182R0011
SA/S8.6.2.1 Switch Actuator, 8-fold, 6 A, Manual Operation, MDRC
Uses potential free contacts to switch 8 independent electrical loads via the ABB i-bus®. Manual operation and display...
2CDG120045R0011
LFO/A1.1 Outside Light Sensor for HS/S4.2.1, SM
Outside Light Sensor for the connection with the Interface HS/S 4.2.1.
2CDG120044R0011
HS/S4.2.1 Outside Light Sensor Interface, MDRC
The device can be used as a twilight switch (1 ... 100 lux) or as a light value switch (100 ... 20.000 lux). One Outside...
2CDG120039R0011
FW/S8.2.1 Radio Time Switch, 8 Channels, MDRC
The Radio Time Switch sends current time and date on the bus. The time can be optionally received via a DCF or GPS...
2CDG110177R0011
IPS/S3.1.1 IP Interface, MDRC
Connects the KNX bus with the Ethernet network. The device uses the KNXnet/IP protocol for communication (Tunneling)....